Product successfully added to your shopping cart
INJ 2113-T
1004066
PHOENIX_CONTACT
1
Injector
Data and telecommunication > Patch cord copper (twisted pair) industry
Safety
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 1004066 |
---|---|
Packing unit | 1 pc |
Note | Made to Order (non-returnable) |
GTIN | 4055626472362 |
Weight per Piece (excluding packing) | 324.720 g |
Custom tariff number | 85176200 |
Country of origin | DE (Germany) |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Ambient temperature (operation) | -40 °C ... 75 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Altitude | 5000 m (For restrictions see manufacturer's declaration) |
Degree of protection | IP20 (Manufacturer's declaration) |
Electrical isolation | VCC // SCM + FE // PoE |
---|---|
Test voltage data interface/power supply | 1.5 kV AC (50 Hz, 1 min.) |
Standards/regulations | IEC 61643-21 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Mounting position | vertical |
Net weight | 324.72 g |
Housing material | Plastic |
Color | gray |
MTTF | 1797 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
733 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) | |
283 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) | |
Conformance | CE-compliant |
UL, USA | UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 |
UL, USA/Canada | Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 |
Class I, Division 2, Groups A, B, C, D | |
UL, Canada | CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 |
Nominal supply voltage | 24 V DC |
---|---|
48 V DC | |
Supply voltage range | 18 V DC ... 57 V DC |
Max. current consumption | 4.2 A |
2.73 A (24 V DC) | |
1.34 A (48 V DC) | |
Power consumption | ≤ 75 W |
Protective circuit | Reverse polarity protection |
Conductor cross section flexible max. | 4.00 mm² |
Conductor cross section flexible min. | 0.75 mm² |
Conductor cross section solid max. | 4.00 mm² |
Conductor cross section solid min. | 0.75 mm² |
Conductor cross section AWG max. | 12 |
Conductor cross section AWG min. | 20 |
Interface 1 | Ethernet |
---|---|
Connection method | Push-in connection |
Transmission length | 100 m (including patch cables) |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 26 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Pin assignment | 1:1 |
Basic functions | PSE/Midspan, compliant with IEEE 802.3af, at |
Serial transmission speed | 10/100/1000 Mbps |
Output nominal voltage | 54 V DC (PoE) |
Output power | 60 W |
Maximum output power | 75 W |
Interface 2 | Ethernet |
Connection method | RJ45 CAT5e |
Designation | Shield current monitoring |
---|---|
Switch-on threshold | ≥ 30 mA |
Local diagnostics | Yellow LED |
Precision | ± 5 % |
Response time | 3 s |
Continuous shield current | ≤ 2 A |
Power consumption | 270 mW (Shield current monitoring) |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Type of test | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
Test result | 10 Hz ... 57 Hz, amplitude ±3.5 mm, 57 Hz ... 150 Hz, 5g |
Type of test | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
Test result | 25g for 11 ms, three shocks in each direction |
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV (Test Level 3) |
Indirect discharge | ± 6 kV |
Standards/regulations | EN 61000-4-3 |
Frequency range | 80 MHz ... 3 GHz (Test Level 3) |
Standards/regulations | EN 61000-4-4 |
Comments | Criterion B |
Standards/regulations | EN 61000-4-5 |
Signal | ± 1 kV (Data line, asymmetrical) |
± 2 kV (I/O cable on field side only, asymmetric) | |
Standards/regulations | EN 61000-6-4 |
EN 61000-4-6 | |
Frequency range | 0.15 MHz ... 80 MHz |
Standards/regulations | IEC 61643-21 |
IEC test classification | C2 |
Conformance | CE-compliant |
UL, USA | UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 |
UL, USA/Canada | Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 |
Class I, Division 2, Groups A, B, C, D | |
UL, Canada | CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 |
Noxious gas test | ISA-S71.04-1985 G3 Harsh Group A |
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE AUTOMATION PHOENIX EN.pdf | 35 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.