INJ 2113-T 1004066 PHOENIX CONTACT Injector View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

INJ 2113-T 1004066 PHOENIX CONTACT Injector

INJ 2113-T

1004066

PHOENIX_CONTACT

Injector

More details


Data and telecommunication > Patch cord copper (twisted pair) industry

Safety

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $711.12
Unit price: $711.12

Quantity Price
1+$711.12
2+$658.52
3+$651.02
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey1004066
Packing unit1 pc
NoteMade to Order (non-returnable)
GTIN4055626472362
Weight per Piece (excluding packing)324.720 g
Custom tariff number85176200
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Dimensional drawing
Width30.2 mm
Height130 mm
Depth120 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 75 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Altitude5000 m (For restrictions see manufacturer's declaration)
Degree of protectionIP20 (Manufacturer's declaration)

General

Electrical isolationVCC // SCM + FE // PoE
Test voltage data interface/power supply1.5 kV AC (50 Hz, 1 min.)
Standards/regulationsIEC 61643-21
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Mounting positionvertical
Net weight324.72 g
Housing materialPlastic
Colorgray
MTTF1797 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day))
733 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day))
283 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
ConformanceCE-compliant
UL, USAUL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
UL, USA/CanadaClass I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4
Class I, Division 2, Groups A, B, C, D
UL, CanadaCSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16

Power supply

Nominal supply voltage24 V DC
48 V DC
Supply voltage range18 V DC ... 57 V DC
Max. current consumption4.2 A
2.73 A (24 V DC)
1.34 A (48 V DC)
Power consumption≤ 75 W
Protective circuitReverse polarity protection
Conductor cross section flexible max.4.00 mm²
Conductor cross section flexible min.0.75 mm²
Conductor cross section solid max.4.00 mm²
Conductor cross section solid min.0.75 mm²
Conductor cross section AWG max.12
Conductor cross section AWG min.20

Serial interface

Interface 1Ethernet
Connection methodPush-in connection
Transmission length100 m (including patch cables)
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.26
Conductor cross section AWG max.16
Stripping length8 mm
Pin assignment1:1
Basic functionsPSE/Midspan, compliant with IEEE 802.3af, at
Serial transmission speed10/100/1000 Mbps
Output nominal voltage54 V DC (PoE)
Output power60 W
Maximum output power75 W
Interface 2Ethernet
Connection methodRJ45 CAT5e

Function

DesignationShield current monitoring
Switch-on threshold≥ 30 mA
Local diagnosticsYellow LED
Precision± 5 %
Response time3 s
Continuous shield current≤ 2 A
Power consumption270 mW (Shield current monitoring)

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Type of testVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result10 Hz ... 57 Hz, amplitude ±3.5 mm, 57 Hz ... 150 Hz, 5g
Type of testShock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result25g for 11 ms, three shocks in each direction
Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV (Test Level 3)
Indirect discharge± 6 kV
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 3 GHz (Test Level 3)
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-4-5
Signal± 1 kV (Data line, asymmetrical)
± 2 kV (I/O cable on field side only, asymmetric)
Standards/regulationsEN 61000-6-4
EN 61000-4-6
Frequency range0.15 MHz ... 80 MHz
Standards/regulationsIEC 61643-21
IEC test classificationC2
ConformanceCE-compliant
UL, USAUL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
UL, USA/CanadaClass I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4
Class I, Division 2, Groups A, B, C, D
UL, CanadaCSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
Noxious gas testISA-S71.04-1985 G3 Harsh Group A

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE AUTOMATION PHOENIX EN.pdf 35 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.