5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...

Images are for illustrative purposes only. Please refer to data sheet for details.
Reference: FB-8SP ISO
Code: 2316311
Manufacturer: PHOENIX CONTACT
Description:
Categories:
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT
LAST VIEWED
| Orderkey | 2316311 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 514 (C-6-2017) |
| GTIN | 4055626306803 |
| Weight per Piece (excluding packing) | 1,190.000 g |
| Custom tariff number | 85389099 |
| Country of origin | US (United States) |
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
| Ambient temperature (operation) | -40 °C ... 80 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 95 % (non-condensing) |
| Degree of protection | IP20 |
| IP20, IP30 over trunk connections |
| Mounting position | On horizontal and vertical DIN rail NS 35 in acc. with EN 60715 |
|---|---|
| Net weight | 1190 g |
| Degree of pollution | 2 |
| Overvoltage category | II |
| Conformance | EMC 2014/30/EU |
| ATEX 2014/34/EU | |
| Fieldbus Foundation | FF-846 |
| Supply voltage range | 16 V DC ... 32 V DC (input on trunk line side) |
|---|---|
| Max. current consumption | 35 mA (trunk, no load) |
| 350 mA (maximum trunk current) | |
| Conductor cross section flexible max. | 0.20 mm² |
| Conductor cross section flexible min. | 2.50 mm² |
| Conductor cross section solid max. | 0.20 mm² |
| Conductor cross section solid min. | 2.50 mm² |
| Max. AWG conductor cross section, flexible | 12 |
| Min. AWG conductor cross section, flexible | 24 |
| Conductor cross section AWG max. | 12 |
| Conductor cross section AWG min. | 24 |
| Interface 1 | Foundation Fieldbus and PROFIBUS PA Segment |
|---|---|
| No. of ports | 8 |
| Connection method | Pluggable COMBICON screw connection for each spur |
| Termination resistor | Integrated termination, activated with bridge located in correct terminals |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Output nominal voltage | ≤ 14 V (each spur) |
| Output current | 35 mA (per spur) |
| Inductance Li | 0 µH |
| Max. output voltage Uo | 16.7 V |
| Input voltage Ui | 32 V |
|---|---|
| Max. output voltage Uo | 16.7 V |
| Max. output current Io | 250 mA |
| Max. output power Po | 1.05 W |
| Group | IIC |
| Max. external capacity Co | 0.39 µF |
| Group | IIB |
| Max. external capacity Co | 2.33 µF |
| Group | IIC |
| Max. external inductivity Lo | 0.56 mH |
| Group | IIB |
| Max. external inductivity Lo | 2.27 mH |
| ATEX | DEMKO 16ATEX 1689X II 2(1) G Ex eb ib mb [ia Ga] IIC T4 Gb II (1D) [Ex ia Da] IIIC FISCO power supply (spur) |
| IECEx | IECEx UL 16.0114X Ex eb ib mb [ia Ga] IIC T4 Gb [Ex ia Da] IIIC FISCO power supply (spur) |
| Safety-related maximum voltage Um | 253 V |
| Type of test | Corrosive resistance in acc. to ANSI-ISA 71.04-1985 - Severity level G3 |
|---|---|
| Designation | Standards/regulations |
| Standards/regulations | Ring wave noise immunidty in acc. with IEC 61000-4-12 |
| Designation | Standards/regulations |
| Standards/regulations | Dry heat in acc. with IEC 61131-2 |
| Designation | Standards/regulations |
| Standards/regulations | Damp heat in acc. with IEC 61131-2 |
| Designation | Standards/regulations |
| Standards/regulations | Shock and vibration in acc. with EN 61131-2 and EN 50178 |
| IEC 61158-2 | |
| Flammability rating according to UL 94 | V0 |
| Shock | 15g for 11 ms |
| Vibration (operation) | 2g, 10 Hz ... 150 Hz |
| Conformance | EMC 2014/30/EU |
| ATEX 2014/34/EU | |
| Fieldbus Foundation | FF-846 |
| Group | IIC |
| IIB | |
| IIC | |
| IIB | |
| ATEX | DEMKO 16ATEX 1689X II 2(1) G Ex eb ib mb [ia Ga] IIC T4 Gb II (1D) [Ex ia Da] IIIC FISCO power supply (spur) |
| IECEx | IECEx UL 16.0114X Ex eb ib mb [ia Ga] IIC T4 Gb [Ex ia Da] IIIC FISCO power supply (spur) |
| UL, USA/Canada | Install in Class I, Div. 2, Groups A, B, C, D Entity/FISCO spur to: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III; Group IIIC Class I, Zone 1 AEx eb ib mb [ia Ga] IIC T4 Gb [AEx ia Da] IIIC FISCO power supply (spur) Ex eb ib mb [ia Ga] IIC T4 Gb [Ex ia Da] IIIC FISCO power supply (spur) |
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP