| Orderkey | 2880888 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 143 (C-6-2013) |
| GTIN | 4046356013130 |
| Weight per Piece (excluding packing) | 191.300 g |
| Custom tariff number | 85363030 |
| Country of origin | DE (Germany) |
| Ambient temperature (operation) | -25 °C ... 75 °C |
|---|---|
| Degree of protection | IP20 (child-proof) |
| Housing material | PA |
|---|---|
| Flammability rating according to UL 94 | V0/HB |
| Standards for cearances and creepage distances | EN 60664-1 |
| EN 61643-11 | |
| EN 61643-1 | |
| Overvoltage category | III |
| Degree of pollution | 2 |
| Total surge current (8/20) µs | 5 kA |
| Color | white |
| For country-specific use in | S, FIN, N |
| Mounting type | Plugging into the mains socket |
| Type | Attachment plug |
| Direction of action | L/N-PE & Signal Line-Shield-Earth Ground |
| EN type | T3 |
|---|---|
| Nominal voltage UN | 230 V AC |
| Arrester rated voltage UC | 275 V AC (L-N) |
| Arrester rated voltage UC(L-N) | 275 V AC |
| Arrester rated voltage UC(L-PE) | 360 V AC |
| Arrester rated voltage UC(N-PE) | 360 V AC |
| Nominal frequency fN | 50 Hz |
| 60 Hz | |
| Nominal current IN | 16 A (30 °C) |
| Residual current IPE | ≤ 1 µA |
| Nominal discharge current In(8/20) µs | 3 kA |
| Max. discharge current Imax(8/20) µs | 8 kA (> 100x 1 kA) |
| Combination wave UOC | 4 kV |
| Energy absorption symmetrical | 140 J (L-N) |
| Enery absorption, asymmetrical | 220 J (L(N)-PE) |
| Voltage protection level Up(L-N) | ≤ 1.2 kV |
| ≤ 1 kV (at 1 kA (8/20 μs)) | |
| Voltage protection level Up(L-PE) | ≤ 1.5 kV |
| Voltage protection level Up(N-PE) | ≤ 1.5 kV |
| Total surge current (8/20) µs | 5 kA |
| Response time (L-N) | ≤ 25 ns (L-N) |
| Response time (L-PE) | ≤ 100 ns (L, N-PE) |
| Surge protection fault message | optical |
| Max. required back-up fuse | 16 A (gL/C) |
| Connection method IN | Grounding plug |
|---|---|
| Connection method OUT | Grounding socket |
| Standards/regulations | IEC 61643-1 |
|---|---|
| EN 61643-11/A11 | |
| SEK SS 428 08 34 | |
| IEC 60884-1 |
| Arrester rated voltage UC | 72 V DC |
|---|---|
| 50 V AC | |
| Arrester rated voltage UC(Core-Shield) | 72 V DC |
| 50 V AC | |
| Arrester rated voltage UC(Shield-Earth) | 380 V DC |
| Nominal current IN | 1.5 A (25 °C) |
| Operating effective current ICat UC | ≤ 1 µA |
| Residual current IPE | ≤ 1 µA |
| Insulation resistance Riso | ≥ 70 MΩ (core-core) |
| ≥ 70 MΩ (shield-PE) | |
| Nominal discharge current In(8/20) µs (line-shield) | 2.5 kA |
| Nominal discharge current In(8/20) µs (shield-earth) | 5 kA |
| Voltage protection level Up(line-shield) | ≤ 700 V (C2 - 2 kA) |
| Voltage protection level Up(shield-ground) | ≤ 1.2 kV (C2 - 5 kA) |
| Response time tA (line-shield) | ≤ 100 ns |
| Response time tA (shield-earth) | ≤ 100 ns |
| Input attenuation aE, asym. | 0.3 dB (≤ 2.4 GHz) |
| Cut-off frequency fg (3 dB), asym. (shield) in 75 Ohm system | > 2.5 GHz |
| Frequency range | 0 Hz ... 2400 MHz |
| Capacity asymmetrical (shield) | typ. 10 pF |
| Nominal pulse current ian (10/1000) µs, asym. (shield) | 120 A |
| Residual voltage at In(line-shield) | ≤ 40 V |
| Residual voltage at In(shield-earth) | ≤ 50 V |
| Impulse durability (line-shield) | C2 - 4 kV/2 kA |
| C3 - 7.5 kV/100 A | |
| Impulse durability (shield-earth) | C2 - 10 kV / 5 kA |
| C3 - 7.5 kV/100 A | |
| D1 - 1 kA | |
| Alternating current carrying capacity (line-shield) | 5 A - 1 s |
| Alternating current carrying capacity (shield-earth) | 10 A - 1 s |
| Pulse reset time (line-shield) | Cannot be measured |
| Overload failure mode (line-line) | Mode 3 |
| Connection method | F connector |
|---|---|
| Connection method IN | F connector, female |
| Connection method OUT | F connector, female |
| Connection method | Via protective contact plug |
|---|
| IEC test classification | C2 |
|---|---|
| C3 | |
| D1 | |
| Standards/regulations | IEC 61643-21 |
| EN 50083 - CLASS A |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP