5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...

Images are for illustrative purposes only. Please refer to data sheet for details.
Reference: PSI-REP-PROFIBUS/12MB
Code: 2708863
Manufacturer: PHOENIX CONTACT
Description:
Categories:
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT
LAST VIEWED
| Orderkey | 2708863 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 318 (C-6-2017) |
| GTIN | 4046356078993 |
| Weight per Piece (excluding packing) | 212.400 g |
| Custom tariff number | 85176200 |
| Country of origin | DE (Germany) |
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
| Ambient temperature (operation) | -20 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
| Altitude | ≤ 5000 m (For restrictions see manufacturer's declaration) |
| ≤ 2000 m (When used in EX zone 2) | |
| Degree of protection | IP20 |
| Noise immunity | EN 61000-4-2 |
| Transmission channels | 2 (1/1), TD, RD, half duplex |
|---|---|
| Bit delay | 1 bit (Direct mode) |
| Bit distortion, input | max. ± 35 % |
| Bit distortion, output | < 6.25 % |
| Electrical isolation | VCC // TBUS // PROFIBUS (A) // PROFIBUS (B) |
| Test voltage data interfaces | 1.5 kV |
| Test voltage data interface/power supply | 1.5 kVrms(50 Hz, 1 min.) |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Noise emission | EN 55011 |
| Net weight | 212.4 g |
| Housing material | PA 6.6-FR |
| Color | green |
| MTBF | 1136 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| 238 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
| MTTF | 1638 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
| 812 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) | |
| 340 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) | |
| Conformance | CE-compliant |
| ATEX | II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
| UL, USA/Canada | cULus listed UL 508 |
| Class I, Zone 2, AEx nA nC IIC T6 | |
| Class I, Zone 2, Ex nA nC IIC T6 Gc X | |
| Class I, Div. 2, Groups A, B, C, D |
| Nominal supply voltage | 24 V DC (With UL approval) |
|---|---|
| Supply voltage range | 18 V DC ... 30 V DC (via pluggable COMBICON screw terminal block) |
| Typical current consumption | < 90 mA (24 V DC) |
| Interface 1 | PROFIBUS acc. to IEC 61158, RS-485 2-conductor |
|---|---|
| Operating mode | Through PROFIBUS connector |
| Connection method | D-SUB-9 female connector |
| File format/coding | UART (11 Bit, NRZ) |
| Data direction switching | Automatic control, min. station response time 2 bits |
| Transmission medium | 2-wire twisted pair, shielded |
| Transmission length | ≤ 1200 m (Depends on transmission speed and cable type) |
| Termination resistor | external |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Output nominal voltage | 5 V DC ±5 % |
| Output current | 50 mA |
| Output name | Relay output |
|---|---|
| Output description | Alarm output |
| Number of outputs | 1 |
| Maximum switching voltage | 30 V DC (1 A) |
| 65 V DC (0.46 A) | |
| 150 V AC (0.46 A) |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Type of test | Free fall in acc. with IEC 60068-2-32 |
| Test result | 1 m |
| Type of test | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
| Test result | 5g, 10...150 Hz, 2.5 h, in XYZ direction |
| Type of test | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
| Test result | 15g, 11 ms period, half-sine shock pulse |
| Noise emission | EN 55011 |
| Noise immunity | EN 61000-4-2 |
| Free from substances that could impair the application of coating | according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard |
| Connection in acc. with standard | CUL |
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | ± 6 kV |
| Standards/regulations | EN 61000-4-3 |
| Frequency range | 80 MHz ... 3 GHz |
| Standards/regulations | EN 61000-4-4 |
| Comments | Criterion B |
| Standards/regulations | EN 61000-4-5 |
| Signal | ± 1 kV |
| Standards/regulations | EN 55011 |
| EN 61000-4-6 | |
| Designation | Air clearances and creepage distances |
| Standards/regulations | DIN EN 50178, DIN EN 60950 |
| Conformance | CE-compliant |
| ATEX | II 3 G Ex nA nC IIC T4 Gc X |
| UL, USA/Canada | cULus listed UL 508 |
| Class I, Zone 2, AEx nA nC IIC T6 | |
| Class I, Zone 2, Ex nA nC IIC T6 Gc X | |
| Class I, Div. 2, Groups A, B, C, D | |
| Noxious gas test | ISA-S71.04-1985 G3 Harsh Group A |
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP