PHOENIX CONTACT  ILC 200 UNI-PAC 2862291 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

ILC 200 UNI-PAC 2862291 PHOENIX CONTACT Controller

Reference: ILC 200 UNI-PAC

Code: 2862291

Manufacturer: PHOENIX CONTACT

Description:

Controller
Inline controller with a local INTERBUS bus interface for the inline installation system, and programming possible according to IEC 61131-3, complete with accessories (connector and marking surface)

Categories:

  • PHOENIX CONTACT > Control Systems (CST)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • PDF
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

  • These delivery times are an estimate any may vary when the item order has been processed.

MORE INFO

Key Commercial Data

Orderkey2862291
Packing unit1 pc
Catalog pagePage 27 (AX-2009)
GTIN4017918909116
Weight per Piece (excluding packing)366.300 g
Custom tariff number85371091
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width73 mm
Height140.5 mm
Depth71.5 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 75 °C
Permissible humidity (operation)5 % ... 85 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 85 % (non-condensing)
Air pressure (operation)70 kPa ... 108 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)66 kPa ... 108 kPa (up to 3500 m above sea level)
Shock25g, Criterion 1, according to IEC 60068-2-27
Vibration (operation)2g, criterion 1 according to IEC 60068-2-6

Control system

Engineering toolPC WORX
Diagnostics toolDIAG+ from version 1.14

Mechanical design

Weight260 g
Diagnostics displayNo
Controller redundancyNo

Data interfaces

InterfaceINTERBUS local bus (master)
Number1
Connection methodInline data jumper
Transmission speed500 kBaud / 2 MBaud (can be switched)
InterfaceHigher-level INTERBUS local bus (slave)
Number1
Connection methodInline data jumper
Transmission speed500 kBaud
InterfaceParameterization/operation/diagnostics
Number1
Connection method6-pos. MINI DIN socket (PS/2)
Transmission speed19200 Baud

Power supply

Typical current consumption250 mA (no local bus device connected during idling, bus inactive)
Supply voltage7.5 V DC (the power supply comes from the upstream bus coupler)
Supply voltage range19.2 V DC ... 30 V DC
Residual ripple±5 %
Power dissipationmax. 1.875 W
Max. total permissible current consumption of all I/O terminal blocksCommunications power (7,5 V DC) the power supply comes from the upstream bus coupler
Analog supply (24 V DC) = 0.5 A

Fieldbus function

Amount of process datamax. 4096 Bit (INTERBUS-Master)
192 Bit (INTERBUS-Slave)
Number of parameter datamax. 8 Byte (configurable)
Number of supported devicesmax. 512
Number of local bus devices that can be connectedmax. 63 (observe current consumption)
Number of devices with parameter channelmax. 62
Number of supported branch terminals with remote bus branchmax. 15

Direct I/Os

Input nameDigital inputs
Number of inputs4
Connection methodInline potential distributor
Connection technology2, 3, 4-wire
Description of the inputInterrupt input, fast counter, pulse generator
Output nameDigital outputs
Number of outputs2
Connection methodSpring-cage connection
Connection technology2, 3, 4-wire
Maximum output current per channel500 mA
Number of pulse direction outputs2
Limit frequency20 kHz
Number of inputs4
Input frequency40 kHz

IEC 61131 runtime system

Engineering toolPC WORX
Program memorytyp. 384 kByte (32 K instructions (IL))
Mass storage330 kByte
Retentive mass storage8 kByte (NVRAM)
Number of control tasks8
Realtime clockIntegrated (battery backup)

Standards and Regulations

Vibration (storage/transport)2g, criterion 1 according to IEC 60068-2-6
Connection in acc. with standardCUL
Shock25g, Criterion 1, according to IEC 60068-2-27
Vibration (operation)2g, criterion 1 according to IEC 60068-2-6

Environmental Product Compliance

REACh SVHC1,2-dimethoxyethane,ethylene glycol dimethyl ether (EGDME) 110-71-4
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.