5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...

Images are for illustrative purposes only. Please refer to data sheet for details.
Reference: AXC F 1050
Code: 2404701
Manufacturer: PHOENIX CONTACT
Description:
Categories:
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT
* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.
Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.
| Orderkey | 2404701 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4055626426310 |
| Weight per Piece (excluding packing) | 225.600 g |
| Custom tariff number | 85371091 |
| Country of origin | DE (Germany) |
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C ... 60 °C up to 2000 m above mean sea level |
| -25 °C ... 55 °C up to 3000 m above mean sea level | |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2, non-condensing, no ice formation) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2, non-condensing, no ice formation) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 58 kPa ... 106 kPa (up to 4500 m above mean sea level) |
| Shock | 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27 |
| Vibration (operation) | 5g |
| Engineering tool | PLCnext Engineer |
|---|---|
| Programming languages supported | Programming in acc. with IEC 61131-3 |
| Configuration tool | Config+ Version 1.01 or later |
| Engineering tool | PLCnext Engineer |
|---|---|
| Program memory | 2 Mbyte |
| Mass storage | 2 Mbyte |
| Retentive mass storage | 48 kByte (NVRAM) |
| Number of control tasks | 8 |
| Realtime clock | Yes |
| Designation | |
|---|---|
| Amount of process data | max. 4096 Bit (Axioline F local bus (input)) |
| max. 4096 Bit (Axioline F local bus (output)) | |
| max. 32768 Bit (per station) | |
| Number of supported devices | max. 63 (per station) |
| Number of local bus devices that can be connected | max. 63 (observe current consumption) |
| Interface | Axioline F local bus |
|---|---|
| Number | 1 |
| Connection method | Bus base module |
| Transmission speed | 100 Mbps |
| Interface | Service |
| Number | 1 |
| Connection method | Micro USB type B |
| Transmission speed | max. 115.2 kbps |
| Interface | Ethernet |
| Number | 2 |
| Connection method | RJ45 socket |
| Transmission speed | 10/100 Mbps |
| Device function | PROFINET controller, PROFINET device |
|---|---|
| Specification | Version 2.3 |
| Update rate | min. 32 ms (16 devices) |
| min. 32 ms (8 devices) | |
| min. 16 ms (4 devices) | |
| min. 8 ms (2 devices) | |
| min. 4 ms (1st device) |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Interference emission | Noise emission test according to EN 61000-6-3 Radio noise emission EN 55032 Class B |
| Immunity to surge | Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV |
| Immunity to burst | Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV |
| Immunity to EF | Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m |
| Immunity to ESD | Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge |
| Immunity to conducted interference | Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V |
| Vibration (storage/transport) | 5g |
| Shock | 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27 |
| Vibration (operation) | 5g |
| Shock (operation) | 10g (Bump endurance test according to EN 60068-2-29) |
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP