Product successfully added to your shopping cart
ULSH201
LS-H201
PANASONIC
1
Sensor head, diffuse reflective, range 300mm, cable 2m
LS500. Sensor head, diffuse reflection, range 750mm
LS-H201_Amplifier-separated Type Digital Laser Sensor_Amplifier-separated Type Digital Laser Sensor LS-500_Sensor heads(Coaxial reflective type)
Digital laser - PANASONIC > LS high precision Digital Laser Sensor - PANASONIC
Brand new product in its original packaging covered by the warranties and certifications provided by PANASONIC
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Product Number | LS-H201 |
| Part Number | LS-H201 |
| Product | Amplifier-separated Type Digital Laser Sensor |
| Details | Sensor heads(Coaxial reflective type) |
| Product name | Amplifier-separated Type Digital Laser Sensor LS-500 |
| Item | Specifications |
|---|---|
| Product Number | LS-H201 |
| Part Number | LS-H201 |
| Regulatory compliance | EMC Directive, RoHS Directive |
| Applicable amplifiers | LS-501(P), LS-501(P)-C2 (Note:When using the thru-beam type LS-H101□ or LS-H102□, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.) |
| Sensing range:H-SP mode | 150mm 5.906 in (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.) |
| Sensing range:FAST mode | 200mm 7.874 in (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.) |
| Sensing range:STD mode | 300mm 11.811 in (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.) |
| Sensing range:U-LG mode | 450mm 17.717 in (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.) |
| Sensing range:U-LG | 600mm 23.622 in (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.) |
| Sensing range:HYPR | 750mm 29.528 in (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.) |
| Spot size | Approx. dia. 2 mm dia. 0.079 in or less (at a distance from the sensor head of 300 mm 11.811 in) |
| Sensing object | Opaque, translucent, or transparent object (Note:Make sure to confirm detection with an actual sensor before use.) |
| Operation indicator | Orange LED (lights up when the amplifier output is ON) |
| Protection | IP40 (IEC) |
| Ambient temperature | -10 to +55degrees + 14 to + 131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70degrees -4 to +158 degrees Fahrenheit |
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Ambient illuminance | Incandescent light: 3,000 ℓx or less at the light-receiving face |
| Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Vibration resistance | 10 to 500 Hz frequency, 1.5 mm double amplitude or maximum acceleration 98 m/s2 in X, Y, and Z direction for 2 hours each. |
| Shock resistance | 98 m / s2 acceleration (10 G approx.) in X, Y and Z directions three times each |
| Emitting element:Type | Red semiconductor laser diode |
| Emitting element:Peak emission wavelength | 660 nm 0.026 mil |
| Emitting element:Laser class | Class 1 [IEC / EN / JIS / GB / KS / FDA] (Note:This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3. |
| Emitting element:Max. output | 2mW |
| Material | Enclosure: PBT Indicator cover: Polycarbonate Beam-emitting / receiving surfaces: Glass |
| Cable | 0.09 mm2 2-core two parallel shielded cables, 2 m 6.562 ft long (Note:Cable cannot be extended.) |
| Weight | Net weight: 50 g approx. Gross weight: 80 g approx. |
| Accessory | MS-LS-1 (Mounting bracket): 1pc. |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PANASONIC SENSORS EN.pdf | 31 Mbytes |
|
| PDF CATALOGUE PANASONIC EN .pdf | 15 Mbytes |
|
| Download general catalog |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.