Product NumberHL-C1C-M
Part NumberHL-C1C-M
ProductUltra High-speed Laser Displacement Sensor [CCD Style]
DetailsController
Product name Ultra High-speed Laser Displacement Sensor HL-C1(Discontinued)

ItemSpecifications
Product NumberHL-C1C-M
Part NumberHL-C1C-M
Connectale sensor headMaximum 2 sensor heads
Supply voltage24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
Current consumptionWhen 1 sensor is connected: 430 mA approx.
When 2 sensors are connected: 550 mA approx.
Sampling rateSelectable from 100 micro s / 144 micro s / 200 micro s / 255 micro s / 332 micro s / 498 micro s / 1,000 micro s
Temprerature characteristicsplus or minus 0.01 % F.S./degrees
Analog output : VoltageOutput voltage: plus or minus 5 V/F.S. [default setting when diffuse reflective mode is selected (Note) ]
Output range: -10.9 to +10.9 V
Output current: Max. 2 mA, Output impedance: 50 Ohm
(Note) If specular reflective mode is selected, then the default setting is plus or minus 4 V/F.S.
Analog output : CurrentOutput current: 4 to 20 mA/F.S. [default setting when diffuse reflective mode is selected (Note 2)]
Output range: 0 to 29.5 mA (maximum of 25 mA at max. load impedance)
Load impedance: 250 Ohm or less
(Note 1) The maximum analog output current will vary with load impedance.
(Note 2) If specular reflective mode is selected, then the default setting is 5.6 to 18.4 mA/F.S.
Alarm outputPhoto-MOS relay
- Maximum load current: 50 mA
- Applied voltage: 30 V DC or less (between alarm output and COM)
- ON impedance: 35 Ohm or less
- Operation time: Max. 2 ms
Alarm output : Output operationOpened when the amount of light is excessive or insufficient.
Alarm output : Short-circuit protectionIncorporated
Judgment outputs (O1, O2)Photo-MOS relay
- Maximum load current: 50 mA
- Applied voltage: 30 V DC or less (between judgment output and COM)
- ON impedance: 35 Ohm or less
- Operation time: Max. 2 ms
Judgment outputs (O1, O2) : Utilization categoryDC-12 or DC-13
Judgment outputs (O1, O2) : Output operationOpened or closed when the threshold value is reached. Determined based on judgment output mode selection. (The threshold value varies with the hysteresis setting.)
Judgment outputs (O1, O2) : Short-circuit protectionIncorporated
Serial input / outputRS-232C
Timing input (Laser emission)Laser emission stops or continues when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input or there is an open circuit: determined based on input mode selection.
Zero set ON inputZero set: ON when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input
Zero set OFF inputZero set: OFF when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input
Indicators : Laser emissionGreen LED (lights up during laser emission from sensor head 1 or sensor head 2, or immediately before laser emission)
Indicators : BRIGHTRed LED (lights up upon disabled measurement due to excessive light at sensor head 1 or 2)
Indicators : DARKRed LED (lights up upon disabled measurement due to insufficient light at sensor head 1 or 2)
Calibration : Shiftplus or minus 20.0000 mm plus or minus 0.787 in
(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Calibration : Span0.9000 to 1.1000
(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Average number of samplesOFF, 2 to 32,768 times (16 steps)
(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Digital filtersHigh pass: OFF, 10 to 2,000 Hz (9 steps)
Low pass: OFF, 10 to 2,000 Hz (9 steps)
(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Calculation functionsL plus or minus KA, L plus or minus KB, L plus or minus K (A plus or minus B)
A, B: Sensor head 1, Sensor head 2 measurement values, L = plus or minus 999.9999, K = 0.0001 to 99.9999
(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Hold functionsSelectable from NORMAL / P-P / PEAK / VALLEY
(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Environmental resistance : Ambient temperature0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Environmental resistance : Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Environmental resistance : Vibration resistance10 to 55 Hz frequency (period: 1 min.) 0.75 mm 0.030 in amplitude in X,Y and Z directions for 30 min. each
Environmental resistance : Shock resistance196 m/s2 (20 G approx.) in X, Y and Z directions for 3 times each
Cable lengthPower line: Less than 10 m 32.808 ft
Signal line: Less than 30 m 98.425 ft
WeightNet weight: 300 g approx.
Accessory-

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.