ANUNCIAR
UDPC101P DPC-101-P PANASONIC Controller DPC100, 1-5V, 4-20mA, PNP, cable 2m View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

UDPC101P DPC-101-P PANASONIC Controller DPC100, 1-5V, 4-20mA, PNP, cable 2m

UDPC101P

DPC-101-P

DPC-101-P

PANASONIC

Controller DPC100, 1-5V, 4-20mA, PNP, cable 2m

Pressure controller separate sensor head, dual display, 3 colors, connector, PNP

DPC-101-P_Head-separated Dual Display Digital Pressure Sensor [For gas]_Head-separated Dual Display Digital Pressure Sensor [For Gas] DPH-100 / DPC-100_Controller

More details


Pressure sensors - PANASONIC > DPC pressure sensor - PANASONIC

Brand new product in its original packaging covered by the warranties and certifications provided by PANASONIC

Total: $185.50
Unit price: $185.50
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Product NumberDPC-101-P
Part NumberDPC-101-P
ProductHead-separated Dual Display Digital Pressure Sensor [For gas]
DetailsController
Product nameHead-separated Dual Display Digital Pressure Sensor [For Gas] DPH-100 / DPC-100

ItemSpecifications
Product NumberDPC-101-P
Part NumberDPC-101-P
CE marking directive complianceEMC Directive, RoHS Directive
Type of pressureGauge pressure
Rated pressure rangeDPH-101□(Compound pressure): -100.0 to +100.0 kPa,
DPH-102□(Positive pressure): 0 to +1.000 MPa,
DPH-103□(Vacuum pressure): 0 to -101.0 kPa
(Note) : It changes automatically according to the connected pressure sensor head.
Set pressure rangeDPH-101□(Compound pressure) : -199.9 to +199.9 kPa (-1.999 to +1.999 kgf/cm2, -19.98 to +19.98 psi, -1.999 to +1.999 bar, -1510 to +1537 mmHg, -59.4 to +60.5 inHg)
DPH-102□(Positive pressure) : -1.050 to +1.050 MPa (-10.71 to +10.71 kgf/cm2, -152.2 to +152.2 psi, -10.50 to +10.50 bar)
DPH-103□(Vacuum pressure) : +101.3 to -101.3 kPa (+1.033 to -1.033 kgf/cm2, +14.70 to -14.70 psi, +1.013 to -1.013 bar, +760 to -760 mmHg, +29.9 to -29.9 inHg)
(Note) : It changes automatically according to the connected pressure sensor head.
Supply voltage12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Power consumptionNormal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
Excluding the current consumption of sensor head and analog output current
Sensor head supply voltageSame as supply voltage
Comparative outputPNP open-collector transistor (2 outputs)
・Maximum source current : 100 mA
・Applied voltage : 30 V DC or less
(between comparative output and +V)
・Residual voltage : 2 V or less (at 100 mA source current)
Comparative output:Output operationNO / NC, selectable by key operation
Comparative output:Output modesEASY mode / Hysteresis mode / Window comparator mode
Comparative output:HysteresisMinimum 1 digit (variable)(however, 2 digits when using psi unit)
Comparative output:RepeatabilityWith vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits)
With compound pressure type connected : within ±0.2 % F.S. (±4 digits)
Comparative output:Response time0.5 ms, 1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Comparative output:Short-circuit protectionIncorporated
Analog output<Analog voltage output>
・Output current : 1 to 5 V DC
・Zero point : within 1 V ± 0.5 % F.S.
(vacuum / positive pressure type)
within 3 V ± 0.5 % F.S. (compound pressure type)
・Span : within 4 V ± 0.5 % F.S.
・Linearity : within ±0.1 % F.S.
・Output impedance : 1 kΩ approx.

<Analog current output>
・Output current : 4 to 20 mA
・Zero point : within 4 mA ± 1 % F.S.
(vacuum / positive pressure type)
within 12 mA ± 1.5 % F.S. (compound pressure type)
・Span : within 16 mA ± 1.5 % F.S.
・Linearity : within ±0.1 % F.S.
・Load resistance : 250 Ω (max.).
Inputs : Sensor head inputInput voltage range : 1 to 5 V DC (over rated pressure range)
Inputs : External input (Auto-reference function/Remote zero-adjustment function)ON voltage : +5 V to +V DC
OFF voltage : +0.6 V DC or less, or open
Input impedance : 10 kΩ approx.
Input time : 1 ms or more
Display4 digits + 4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Display : Displayable pressure rangeVacuum pressure : +5.1 to -101.3 kPa,
Positive pressure : -0.050 to +1.020 MPa,
Compound pressure : -101.3 to +105.0 kPa
Operation indicatorOrange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON)
ProtectionIP40 (IEC)
Ambient temperature-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
Ambient humidity35 to 85 % RH, Storage : 35 to 85 % RH
Voltage withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
Shock resistance100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Temperature characteristicsWithin ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉)
MaterialEnclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber
Connecting methodConnector
Cable lengthTotal length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
WeightNet weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx.
AccessoriesCN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label : 1 set
RemarkWhere measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
The values specified above are applied only to the controller.

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.