J77MN-U-110 234325 OMRON Switchgear Low Voltage Undervoltage 110Vac View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

J77MN-U-110 234325 OMRON Switchgear Low Voltage Undervoltage 110Vac

J77MN-U-110

234325

OMRON

Available

Ship on today

Switchgear Low Voltage Undervoltage 110Vac

More details


Motor Circuit Protectors Protection Breaker

Other Low Voltage Switchgear

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



J7MNMotor protection circuit breakers
J7MN motor protection circuit breakers from 0.10 A to 100 A
J7MN starters protect motors against thermal overload and short circuit.
The J7MN can be equippedwith additional auxiliary contacts, tripping indicator
(alarm), undervoltage release and/or shunt release. All modelscan be locked for safe maintenance.
• Rated operational currents of 32 A for the rocker type
• Rated operational currents of 32 A, 63 A and100A for the rotary types
• Switching capacity is 100 kA/415 V up-to 13 A and50 kA/415V up-to100 A
• Electrical/mechanical link modulesavailableup-to11 kW motorprotectionunits
•All components are finger proof
Ordering information
Rated
Suitable for motors
Current setting range Short-circuit breaking
Size in mm (H × W × D) Order code
current in A
3 ~ 400 V kW
Thermal
overload release A
Instantaneous
short-circuit release A
capacity at 3 ~ 400 V kA
0.16–0.10– 0.162.110098 × 45 × 75J7MN-3P-E16
0.250.06 0.16–0.253.3 100J7MN-3P-E25
0.40.09 0.25–0.45.2 100J7MN-3P-E4
0.630.18 0.4–0.638.2100J7MN-3P-E63
10.25 0.63–1 13100J7MN-3P-1
1.6 0.55 1–1.6 20.8 100J7MN-3P-1E6
2.5 0.75 1.6–2.532.5 100J7MN-3P-2E5
41.5 2.5–4 52100J7MN-3P-4
62.2 4–678100J7MN-3P-6
835–8104100J7MN-3P-8
1046–1013050J7MN-3P-10
135.5 9–1316950J7MN-3P-13
177.5 11–1722120J7MN-3P-17
227.5 14–2228615J7MN-3P-22
261118–2633815J7MN-3P-26
321522–3241615J7MN-3P-32
0.16–0.10–0.162.110098 × 45 × 100J7MN-3R-E16
0.250.06 0.16–0.253.3 100J7MN-3R-E25
0.40.09 0.25–0.45.2 100J7MN-3R-E4
0.630.18 0.4–0.638.2100J7MN-3R-E63
10.25 0.63–1 13100J7MN-3R-1
1.6 0.55 1–1.6 20.8 100J7MN-3R-1E6
2.5 0.75 1.6–2.532.5 100J7MN-3R-2E5
41.5 2.5–4 52100J7MN-3R-4
62.2 4–678100J7MN-3R-6
835–8104100J7MN-3R-8
1046–10130100J7MN-3R-10
135.5 9–13169100J7MN-3R-13
177.5 11–1722150J7MN-3R-17
227.5 14–2228650J7MN-3R-22
261118–2633850J7MN-3R-26
321522–3241650J7MN-3R-32
2612.518–2633850140 × 55 × 144J7MN-6R-26
321522–3241650J7MN-6R-32
4018.528–4052050J7MN-6R-40
502234–5065050J7MN-6R-50
633045–6381950J7MN-6R-63
633045–6381950165 × 70 × 171J7MN-9R-63
753755–7597550J7MN-9R-75
904570–90117050J7MN-9R-90
100–80–100130050J7MN-9R-100
631
J7MNMotor protection circuit breakers
Accessories
DescriptionVersionFor circuit breaker Order code
Transverse auxiliary contact block
Contact block 1 NO + 1 NC AllJ77MN-11F
2NO J77MN-20F
2NC J77MN-02F
Auxiliary contact block for left hand side mounting (max. 2 pc. per circuit breaker)
Contact block (9 mm) 1 NO + 1 NCAll J77MN-11S
2NO J77MN-20S
2NC J77MN-02S
Signalling switch for left hand side mounting (max. 1 pc. per circuit breaker)
Signalling switch (18 mm) 1 NO + 1 NC any tripping conditionJ7MN-3P/-3R J77MN-TA-11S J7MN-6R/-9R J77MN-TB-11S
1 NO + 1 NC short circuit tripping conditionAll J77MN-T-11S
Undervoltage releases for right hand side mounting (max 1 pc. per circuit breaker)
AC 50 Hz AC 60 Hz
Trips the circuit breaker when the voltage is interrupted. Pre- vents the motor from being restarted accidentally when the voltage is restored, suitable for EMERGENCY STOP according to VDE 0113
24 V 28 V AllJ77MN-U-24
110–127 V 120V J77MN-U-110
220–230 V 240–260 VJ77MN-U-230
240 V277 V J77MN-U-240
380–400 V 440–460 VJ77MN-U-400
415–440 V 460–480 VJ77MN-U-415
Shunt releases for right hand side mounting (max 1 pc. per circuit breaker)
AC 50 Hz AC 60 Hz
Trips the circuit breaker when the release coil is energized
Terminal block
24 V 28 V AllJ77MN-S-24
110–127 V 120V J77MN-S-110
220–230 V 240–260 VJ77MN-S-230
240 V277 V J77MN-S-240
380–400 V 440–460 VJ77MN-S-400
415–440 V 460–480 VJ77MN-S-415
Terminal block Up to 600V according to UL 489not for transverse auxiliary contact block
J7MN-3R J77MN-TB32
J7MN-9R J77MN-TB100
Insulated 3-Phase Busbar System IP20
DescriptionConnection typeVersion For Units (MPCB) Order code
3-phase busbars
modular spacing = 45 mm
Spadefor 2 units J7MN-3P J7MN-3R J77MN-CPM-3-45-2S for 3 units J77MN-CPM-3-45-3S for 4 units J77MN-CPM-3-45-4S for 5 units J77MN-CPM-3-45-5S
Line side terminal 3-pole, connection from above
conductor cross-section solid or stranded 6–25 mm² with end sleeve 4–16 mm²
Spadeacc. IEC/EN 60947-1, 60947-2,
60947-4-1 and VDE 0660
J7MN-3P J7MN-3R J77MN-BTC-63-SE
Line side terminal 3-pole, connection from above
conductor cross-section solid or stranded 6–25 mm² with end sleeve 4–16 mm²
Spadeup to 600V acc.UL 489J7MN-3P J7MN-3R J77MN-BTC-63-SEV
Shrouds for unused terminals on busbar system Spade J7MN-3P J7MN-3RJ77MN-TA-63S
632
J7MNMotor protection circuit breakers
Specifications
TypeJ7MN-3PJ7MN-3RJ7MN-6RJ7MN-9R Number of poles3333
Max. rated current Inmax (= max. rated operational current Ie)
Permissible ambient temperature
A323263100
Storage/transport–50 to 80°C
Operation–20 to 60°C
Rated operational voltage UeV 690
Rated frequencyHz 50/60
Rated insulation voltage UiV 690
Rated impulse withstand voltage Uimp
kV 6
Utilization category IEC 60 947-2 (circuit breaker)A
IEC 60 947-4-1 (motor starter) AC-3
ClassAccording to IEC 60 947-4-110
Degree of protection According to IEC 60 529IP20IP20IP20IP20
Phase failure sensitivityAccording to IEC 60 947-4-1Yes
Explosion protection According to EC Directive
94191EC
Yes
Isolator characteristicsAccording to IEC 60 947-3 Yes
Main and EM. STOP switch characteristics
According to IEC 60 204-1 (VDE113)
Yes
Safe isolation between main and auxiliary circuits According to DIN VDE 0106
Part 101
Up to 400 V + 10%Yes
Up to 415 V + 5%Yes
Mechanical endurance Operating cycles 100,000 100,000 50,000 50,000
Electrical endurance 100,000 100,000 25,000 25,000
Max. operating frequency per1/h 25252525
hour (motor starts)
633

Datasheet - PDF

Title: Language: Size: Type:
pdf1-mostradoOMRON - J77MN-U-110 - 234325 English 215 Kbytes pdf1-mostradoOMRON - J77MN-U-110 - 234325
pdf2-mostradoOMRON - J77MN-U-110 - 234325 English 2 Mbytes pdf1-mostradoOMRON - J77MN-U-110 - 234325

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.