ANUNCIAR

CS1W-SCU21-V1 CS1W0383A CS1WSCU21V1,1 OMRON Module 2 RS232C

CS1W-SCU21-V1

CS1W0383A

CS1WSCU21V1.1

OMRON

Module 2 RS232C

Serial communications unit, 2 x RS-232C ports, Protocol Macro, Host Link, 1:N NT Link, No protocol, Serial Gateway (CompoWay/F, Modbus-RTU, Modbus-ASC

More details


PLC's > PLC communication module

Control Systems > CS1

Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

Total: $1,724.61
Unit price: $1,724.61
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



CS-Series communication unitsRack PLC
Open to any communication, standard or user-defined
CS1 provides both standardised open networks interfaces, and cost efficient, high-
speed proprietary network links. Datalinks between PLCs, or to higher-level informa- tion systems can be made using Serial or Ethernet links, or the easy-to-useController Link network.
Omron supportsthe 2 major field networks,DeviceNet and PROFIBUS-DP. For high-
speed field I/O, Omron's own CompoBus/S offers an unsurpassedease of installation. Fully user-configurable serial and CAN-based communication can be used to emulate a variety of application-specific protocols. EtherNet/IP units provide data link func- tions to share large amounts of data between PLCs. ThePROFINET-IO controller to-
getherwith the SmartSlice modularI/O system offers ethernet-basedI/O with controller- and network redundancy.
Ordering information
TypePorts Protocols Unit classRemarksConnection typeOrder code
Serial 2 × RS-232CCompoWay/F, Host Link, NT link, Modbus, CPU bus unit–9-pin D-SubCS1W-SCU21-V1
User-defined
Serial 2 × RS-232C/RS-485 CompoWay/F, Host Link, NT link, Modbus, CPU bus unit–9-pin D-SubCS1W-SCU31-V1
User-defined
Serial 2 × RS-232CCompoWay/F, Host Link, NT link, Modbus, CPU option board –9-pin D-SubCS1W-SCB21-V1
User-defined
Serial 1 × RS-232C +
1 × RS-422/RS-485
CompoWay/F, Host Link, NT link, Modbus, CPU option board –9-pin D-SubCS1W-SCB41-V1
User-defined
GP-IBMaster/Slaveselectable GP-IB instrument communication
Ethernet1 × 100 Base-Tx UDP, TCP/IP, FTP server,
SMTP (e-mail),SNTP (timeadjust), FINS routing, socket service
Special I/O unit –GP-IB CS1W-GPI01
CPU bus unit–RJ45CS1W-ETN21
Controller link2-wire twisted pairOmron proprietary CPU bus unit–2-wire screw + GND CS1W-CLK23
Optical HPCF–2 × HPCF connectorCS1W-CLK13
Optical graded-index fiber–4 × ST connectorCS1W-CLK53
EtherNet/IP 1 × 100 Base-TxEtherNet/IP, UDP, TCP/IP, FTP server, SNTP, SNMP
CPU Bus unit31 mmRJ45CS1W-EIP21
DeviceNet1 × CANDeviceNet CPU bus unit–5-p detachable CS1W-DRM21-V1
CompoNet4-wire, data + power to slaves CompoNet (CIP-based)Special I/O unit –4-p detachable IDC
CS1W-CRM21
(Master)
or screw
CompoBus/S2-wire (Master) Omron proprietary Special I/O unit –2-wire screw +
2-wire power
CS1W-SRM21
PROFIBUS-DP1 × RS-485 (Master)DP, DPV1 CPU bus unit–9-pin D-SubCS1W-PRM21
CAN1 × CANCANopen, User-defined CPU bus unit–5-p detachable CS1W-CORT21
PROFINET IO1 × 100 Base-Tx
PROFINET IO controller
FINS UDP CPU bus unit–RJ45CS1W-PNT21
PROFIBUS-DP1 × RS-485 (Slave) DPC200H special
I/O unit
C200H units cannot be used on CS1D systems
9-pin D-SubC200HW-PRT21
Accessories
DescriptionConnection typeOrder code
RS-232C to RS-422/RS-485 signal converter. Mounts directly on serial port. 9-pin D-sub to screw clamp CJ1W-CIF11 terminals
Controller link PCI board with support softwarePCI, wired CLK 3G8F7-CLK23-E Controller link PCI board with support softwarePCI, HPCF connectors 3G8F7-CLK13-E Controller link PCI board with support softwarePCI, ST connectors3G8F7-CLK53-E Controller link repeater unit (wire to wire)Screw - ScrewCS1W-RPT01
Controller link repeater unit (wire to HPCF fiber) Screw - HPCF connectorCS1W-RPT02
Controller link repeater unit (wire to graded-index glass fiber)Screw - ST connectorCS1W-RPT03
PROFIBUS DP to RS-422/RS-485 Serial Gateway. User-configurable, with Omron protocols built-in.9-pin D-sub to screw clampPRT1-SCU11 terminals
PROFINET IO + ModBus/TCP to Modbus/RTU (RS-485) Gateway. 3 × RJ45 to screw clamp terminals
EJ1N-HFU-ETN
Note:For Ethernet Cables and Accessories, see page 81
43


ETIM for 296512 PLC's (EC001423)
Feature Name Feature Value
Explosion safety category for dust (EF003998) None
Performance level according to EN ISO 13849-1 (EF007399) Level a
Type of data transmission (EF008225) Serial
SIL according to IEC 61508 (EF009889) None
Explosion safety category for gas (EF003997) None
Radio standard UMTS (EF008525) No
Supporting protocol for PROFIsafe (EF007526) No
Certified for UL hazardous location class III (EF017627) No
Supporting protocol for PROFIBUS (EF003052) No
Radio standard GPRS (EF008523) No
Supporting protocol for EtherCAT (EF017564) No
Certified for UL hazardous location class II (EF017625) No
Appendant operation agent (Ex ib) (EF004142) No
Certified for UL hazardous location class I (EF017622) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for other bus systems (EF003062) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for SERCOS (EF006657) No
Appendant operation agent (Ex ia) (EF004141) No
IO link master (EF007298) No
Supporting protocol for Modbus (EF003057) Yes
Supporting protocol for KNX (EF003055) No
Redundancy (EF003156) No
Certified for UL hazardous location group G (non-conductive dusts) (EF017639) No
Supporting protocol for PROFINET CBA (EF007524) No
Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) No
Supporting protocol for LON (EF003017) No
Supporting protocol for SUCONET (EF003060) No
Radio standard Bluetooth (EF007178) No
Suitable for safety functions (EF001597) No
Certified for UL hazardous location group E (metal dusts) (EF017637) No
With optical interface (EF003028) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Radio standard WLAN 802.11 (EF007179) No
Certified for UL hazardous location group A (acetylene) (EF017632) No
Radio standard GSM (EF008524) No
Supporting protocol for INTERBUS (EF003054) No
Certified for UL hazardous location division 2 (EF017629) No
Supporting protocol for Data-Highway (EF003058) No
Certified for UL hazardous location division 1 (EF017628) No
Supporting protocol for PROFINET IO (EF007525) No
Certified for UL hazardous location group D (propane) (EF017636) No
Supporting protocol for ASI (EF003051) No
Certified for UL hazardous location group C (ethylene) (EF017635) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Certified for UL hazardous location group B (hydrogen) (EF017633) No
With potential separation (EF003272) No
Number of HW-interfaces CAN (EF017563) 0
Number of HW-interfaces other (EF003027) 0
Number of HW-interfaces parallel (EF003026) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces RS-232 (EF003021) 1
Number of HW-interfaces RS-422 (EF003022) 1
Number of HW-interfaces RS-485 (EF003023) 1
Number of HW-interfaces serial TTY (EF003024) 0
Height (EF000040) 130 mm
Number of HW-interfaces wireless (EF006933) 0

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.