ANUNCIAR
CS1W-SCB41-V1 CS1W0382C CS1WSCB41V1,1 OMRON Card 1 RS232C + 1 RS422 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CS1W-SCB41-V1 CS1W0382C CS1WSCB41V1,1 OMRON Card 1 RS232C + 1 RS422

CS1W-SCB41-V1

CS1W0382C

CS1WSCB41V1.1

OMRON

Card 1 RS232C + 1 RS422

Serial communications board, 1 x RS-232C port, 1 x RS422/485 port, supports protocol macro backup from memory card

More details


PLC's > PLC communication module

Control Systems > CS1

Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

Total: $1,196.13
Unit price: $1,196.13
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Features

The dual-redundant PLC system for never-fail control

CS1D adds a number of dual-redundancy options to the well-proven CS1 architecture to ensure around-the-clock operation without minimal downtime. Duplex CPUs, with or without loop control functions, are continuously cross-checked for errors, without the need for special programs to be written by the user. An even simpler way to increase system availability is to use dual power supply units. Hot swapping of CPUs, power supplies and I/O units allow system maintenance with little or no process interruption.

  • Choose the level of redundancy needed; CPU, power supply, communication
  • No special programming or software tools required
  • Hot-swapping of I/O units
  • All standard CS1 I/O units can be mounted
  • Ideal for control of power generators, water supply utilities, 24/7 production.

Ordering information

Max. Digital I/O points

Program capacity

Data memory capacity

Logic execution speed

Max. I/O units

Additional functions

Order code

5120

250K steps

448K words

20 ns

80

-

CS1H-CPU67H

71

Supports duplex power supply and I/O hot-swapping

CS1D-CPU67S

68

CPU for full dual-redundancy

CS1D-CPU67H

CPU for full dual-redundancy, with loop control board

CS1D-CPU67P

120K steps

256K words

80

-

CS1H-CPU66H

60K steps

128K words

80

-

CS1H-CPU65H

71

Supports duplex power supply and I/O hot-swapping

CS1D-CPU65S

68

CPU for full dual-redundancy

CS1D-CPU65H

CPU for full dual-redundancy, with loop control board

CS1D-CPU65P

30K steps

64K words

80

-

CS1H-CPU64H

20K steps

-

CS1H-CPU63H

60K steps

40 ns

-

CS1G-CPU45H

1280

30K steps

40

-

CS1G-CPU44H

35

Supports duplex power supply and I/O hot-swapping

CS1D-CPU44S

960

20K steps

30

-

CS1G-CPU43H

10K steps

-

CS1G-CPU42H

26

Supports duplex power supply and I/O hot-swapping

CS1D-CPU42S

Accessories

Description

Remarks

Order code

High-speed data collection and storage unit, with CF card slot and Ethernet port

CPU bus unit

CS1W-SPU01-V2

High-speed data collection and storage unit, with CF card slot and 2 Ethernet ports

CPU bus unit

CS1W-SPU02-V2

Duplex unit, required for CS1D-CPU6_H systems

-

CS1D-DPL01

Serial communication option board, 2 x RS-232C

-

CS1W-SCB21-V1

Serial communication option board, 1 x RS-232C + 1 x RS422/RS-485

-

CS1W-SCB41-V1

Loop control option board

50 control blocks max.

CS1W-LCB01

Loop control option board

300 control blocks max.

CS1W-LCB05

Replacement battery set, for all CS1 CPUs

-

CS1W-BAT01

Compact Flash memory card, 128 MB, for all models (not required for operation)

Industrial grade

HMC-EF183

Compact Flash memory card, 256 MB, for all models (not required for operation)

Industrial grade

HMC-EF283

Compact Flash memory card, 512 MB, for all models (not required for operation)

Industrial grade

HMC-EF583

Compact Flash PC-Card adapter

-

HMC-AP001

CX-One, integrated software for programming and configuration of all Omron control system components

-

CX-ONE-AL__C-E

Connection cable, D-Sub 9-pin PC serial port to PLC peripheral port

length: 2.0 m

CS1W-CN226

Connection cable, D-Sub 9-pin PC serial port to PLC peripheral port

length: 6.0 m

CS1W-CN626

USB to serial conversion cable

-

CS1W-CIF31


ETIM for 296511 PLC's (EC001423)
Feature Name Feature Value
Explosion safety category for dust (EF003998) None
Performance level according to EN ISO 13849-1 (EF007399) Level a
Type of data transmission (EF008225) Serial
SIL according to IEC 61508 (EF009889) None
Explosion safety category for gas (EF003997) None
Radio standard UMTS (EF008525) No
Supporting protocol for PROFIsafe (EF007526) No
Certified for UL hazardous location class III (EF017627) No
Supporting protocol for PROFIBUS (EF003052) No
Radio standard GPRS (EF008523) No
Supporting protocol for EtherCAT (EF017564) No
Certified for UL hazardous location class II (EF017625) No
Appendant operation agent (Ex ib) (EF004142) No
Certified for UL hazardous location class I (EF017622) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for other bus systems (EF003062) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for SERCOS (EF006657) No
Appendant operation agent (Ex ia) (EF004141) No
IO link master (EF007298) No
Supporting protocol for Modbus (EF003057) Yes
Supporting protocol for KNX (EF003055) No
Redundancy (EF003156) No
Certified for UL hazardous location group G (non-conductive dusts) (EF017639) No
Supporting protocol for PROFINET CBA (EF007524) No
Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) No
Supporting protocol for LON (EF003017) No
Supporting protocol for SUCONET (EF003060) No
Radio standard Bluetooth (EF007178) No
Suitable for safety functions (EF001597) No
Certified for UL hazardous location group E (metal dusts) (EF017637) No
With optical interface (EF003028) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Radio standard WLAN 802.11 (EF007179) No
Certified for UL hazardous location group A (acetylene) (EF017632) No
Radio standard GSM (EF008524) No
Supporting protocol for INTERBUS (EF003054) No
Certified for UL hazardous location division 2 (EF017629) No
Supporting protocol for Data-Highway (EF003058) No
Certified for UL hazardous location division 1 (EF017628) No
Supporting protocol for PROFINET IO (EF007525) No
Certified for UL hazardous location group D (propane) (EF017636) No
Supporting protocol for ASI (EF003051) No
Certified for UL hazardous location group C (ethylene) (EF017635) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Certified for UL hazardous location group B (hydrogen) (EF017633) No
With potential separation (EF003272) No
Number of HW-interfaces CAN (EF017563) 0
Number of HW-interfaces other (EF003027) 0
Number of HW-interfaces parallel (EF003026) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of HW-interfaces USB (EF003025) 0
Width (EF000008) 35 mm
Number of HW-interfaces RS-232 (EF003021) 2
Number of HW-interfaces RS-422 (EF003022) 1
Number of HW-interfaces RS-485 (EF003023) 1
Number of HW-interfaces serial TTY (EF003024) 0
Height (EF000040) 130 mm
Depth (EF000049) 100 mm
Number of HW-interfaces wireless (EF006933) 0

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.