D4DS-K2 134023 OMRON Security Product, vertical pin D4NS View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

D4DS-K2 134023 OMRON Security Product, vertical pin D4NS

D4DS-K2

134023

OMRON

Available

Ship on today

Security Product, vertical pin D4NS

More details


Safety

D4DL/DS/DH/DR/GL/NL/NH/NS

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Ordering information

Switches (with approved direct opening contacts)

Type

Contact configuration

Conduit opening/connector

Order code

1-conduit

Slow-action

1NC/1NO

M20

D4NS-4AF

2NC

M20

D4NS-4BF

2NC/1NO

M20

D4NS-4CF

3NC

M20

D4NS-4DF

Slow-action MBB contact

1NC/1NO

M20

D4NS-4EF

2NC/1NO

M20

D4NS-4FF

Operation keys (order separately)

Type

Order code

Horizontal mounting

 

D4DS-K1

Vertical mounting

 

D4DS-K2

 

Type

Order code

Adjustable mounting (horizontal)

 

D4DS-K3

Adjustable mounting
(horizontal/vertical)

 

D4DS-K5

Specifications

Degree of protection

IP67 (EN60947-5-1) (This applies for the switch only. The degree of protection for the key hole is IP00.)

Durability

Mechanical

1,000,000 operations min.

Electrical

500,000 operations min. for a resistive load of 3 A at 250 VAC

300,000 operations min. for a resistive load of 10 A at 250 VAC

Operating speed

0.05 to 0.5 m/s

Operating frequency

30 operations/minute max.

Direct opening force

60 N min.

Direct opening travel

10 mm min.

Minimum applicable load

Resistive load of 1 mA at 5 VDC (N-level reference value)

Protection against electric shock

Class II (double insulation)

Pollution degree (operating environment)

3 (EN60947-5-1)

Contact gap

2×2 mm min

Conditional short-circuit current

100 A (EN60947-5-1)

Rated open thermal current (Ith)

10 A (EN60947-5-1)

Ambient temperature

Operating: -30°C to 70°C with no icing

Note: The above values are initial values.


1.The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40 to 70%. For more details, consult your Omron representative.

2.These figures are minimum requirements for safe operation.

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.