E3X-MDA8 323856 OMRON Photoelectric sensor, display Double 3h PNP Teach cc 2-fiber connector View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

E3X-MDA8 323856 OMRON Photoelectric sensor, display Double 3h PNP Teach cc 2-fiber connector

E3X-MDA8

323856

OMRON

Available Ship on today

Photoelectric sensor, display Double 3h PNP Teach cc 2-fiber connector

More details


Fiber Optic Sensors Optical

E3X

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Ordering information

 

Item

Functions

Order code

NPN output

PNP output

Pre-wired

AND/OR output

E3X-MDA11

E3X-MDA41

Fiber amplifier connector

AND/OR output

E3X-MDA6

E3X-MDA8

Fiber amplifier connectors

Shape

Type

Comment

Order code

Fiber amplifier
connector

2 m PVC cable

E3X-CN21

30 cm PVC cable with M12 plug connector (4 pin)

E3X-CN21-M1J 0.3M

30 cm PVC cable with M8 plug connector (4 pin)

E3X-CN21-M3J-2 0.3M

Specifications

Item

E3X-MDA

Light source (wave length)

Red LED (650 nm)

Power supply voltage

12 to 24 VDC±10%, ripple (p-p) 10% max.

Protective circuits

Power supply reverse polarity protection, output short-circuit protection, mutual interference prevention

Response time

Super-high-speed mode

130 µs for operation and reset respectively

Standard mode

1 ms for operation and reset respectively

High-resolution mode

4 ms for operation and reset respectively

Sensitivity setting

Teaching and digital up/down keys

Functions

Power tuning

Light emission power and reception gain, digital control method

Timer function

Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)

I/O settings

Output setting (select from channel 2 output, AND, OR, leading edge sync, falling edge sync, or differential output)

Digital displays

Select from the following: Incident level for channel 1 + incident level for channel 2, Incident level + threshold, incident level percentage + threshold, incident light peak level + no incident light bottom level, minimum incident light peak level + maximum no incident light bottom level, long bar display, incident level + peak hold, incident level + channel

Degree of protection

IEC 60529 IP50 (with protective cover attached)

 


1.Order connector separately.

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.