E3X-CN12 336331 OMRON Photoelectric sensor, 1h connection Cable Slave E3X-DA-N View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

E3X-CN12 336331 OMRON Photoelectric sensor, 1h connection Cable Slave E3X-DA-N

E3X-CN12

336331

OMRON

Available Ship on today

Photoelectric sensor, 1h connection Cable Slave E3X-DA-N

More details


Fiber Optic Sensors Optical

E3X

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Ordering information

 

Type

Connecting method

Inputs/outputs

Order code

NPN output

PNP output

Standard models

 

Pre-wired (2 m)

1 output

E3NX-CA11 2M

E3NX-CA41 2M

 

Wire-saving Connector

1 output

E3NX-CA6

E3NX-CA8

Advanced models

 

Pre-wired (2 m)

2 outputs + 1 input

E3NX-CA21 2M

E3NX-CA51 2M

Model for Sensor Communications Unit

 

Connector for Sensor Communications Unit

-

E3NX-CA0

Specifications

 

Item

Type

Standard models

Advanced models

Model for Sensor Communications Unit

NPN output

E3NX-CA11

E3NX-CA6

E3NX-CA21

E3NX-CA0

PNP output

E3NX-CA41

E3NX-CA8

E3NX-CA51

Connecting method

Pre-wired

Wire-saving Connector

Pre-wired

Connector for Sensor Communications Unit

I/O

Outputs

1 output

2 outputs

-

External input

-

1 input

Light source (wavelength)

White LED (420 to 700 nm)

Supply voltage

10 to 30 VDC, including 10% ripple (p-p)

Supplied from the connector through the Sensor Communications Unit.

Power consumption

At Power Supply Voltage of 24 VDC

Normal mode: 960 mW max. (Current consumption: 65 mA max.)

Eco function ON: 720 mW max. (Current consumption: 30 mA max.)

Eco function LO: 800 mW max. (Current consumption: 33 mA max.)

Control output

Load power supply voltage

30 VDC max., open-collector output

-

Load current

Groups of 1 to 3 Amplifiers: 100 mA max.,

Groups of 4 to 30 Amplifiers: 20 mA max.

Residual voltage

At load current of less than 10 mA: 1 V max.

At load current of 10 to 100 mA: 2 V max.

OFF current

0.1 mA max.

Protection circuits

Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection

Power supply reverse polarity protection

Sensing method

Contrast Mode: Light intensity discrimination for RGB (initial state/after 2-point tuning) (R+G+B light intensity discrimination for 1-point tuning)

Color Mode: RGB ratio discrimination

Response time

Super-high-speed Mode (SHS)

Operate or reset: 50 µs (only in Contrast Mode)

High-speed Mode (HS)

Operate or reset: 250 µs

Standard Mode (Stnd)

Operate or reset: 1 ms

Giga-power Mode (GIGA)

Operate or reset: 16 ms

Sensitivity adjustment

Smart Tuning (2-point tuning, full autotuning, or 1-point tuning (1% to 99%)) or manual adjustment

Maximum connectable units

30 Units

30 Units (When connected to OMRON NJ-series Unit)

Functions

Operation mode

Contrast Mode: NO (Light-ON) or NC (Dark-ON)

Color Mode: NO (ON for match: ON for same color as registered color) or NC (ON for mismatch: ON for different color from registered color)

Timer

Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer (Counted by 0.1 s in a range of 0.1 to 0.5 ms, by 0.5 ms for 0.5 to 5 ms, and by 1 ms for 5 to 9999 ms. Default: 10 ms, Error: 0.1 ms)

Zero reset

Contrast Mode only

Negative values can be displayed. (Threshold level is shifted.)

Resetting settings

Select from initial reset (factory defaults), user reset (saved settings), or bank reset.

Eco mode

Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).

Bank switching

Select from banks 1 to 8.

Power tuning level

Set from 100 to 9,999. (The RGB maximum incident level at Smart Tuning is adjusted to the power tuning level.)

Output 2

-

Normal, error output, AND output, or OR output

-

External input

-

Select from input OFF, tuning, full-auto tuning, emission OFF, bank 1 and 2 switching, bank 1 through 8 switching, or zero reset.

-

Changing the displays

Threshold level and incident level, channel number and incident level, RGB display and incident level, or bank display and incident level

*1 The E3NW-ECT Sensor Communications Unit can be used, but the E3NW-CRT/CCL, E3X-DRT21-S, and E3X-CRT/ECT Sensor Communications Units cannot be used.

*2 Two sensor outputs are allocated in the programmable logic controller (PLC) I/O table. PLC operation via Communications Unit enables reading detected values and changing settings.

*3 The following details apply to the input.

 

Contact input (relay or switch)

Non-contact input (transistor)

NPN

ON: Shorted to 0 V (Sourcing current: 2 mA max.).

OFF: Open or shorted to Vcc.

ON: 1.5 V max. (Sourcing current: 2 mA max.)

OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1 mA max.)

PNP

ON: Shorted to Vcc (Sinking current: 3 mA max.).

OFF: Open or shorted to 0 V.

ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.)

OFF: 1.5 V max. (Leakage current: 0.1 mA max.)

*4 Power consumption
At Power Supply Voltage of 10 to 30 VDC
Normal mode: 1,080 mW max. (Current consumption: 36 mA max. at 30 VDC, 74 mA max. at 10 VDC)
Eco function ON: 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 50mA max. at 10 VDC)
Eco function LO: 930 mW max. (Current consumption: 31 mA max. at 30 VDC, 55 mA max. at 10 VDC)

*5 The mutual interference prevention function is disabled if the detection mode is set to Super-high-speed Mode.

*6 The bank is not reset by the user reset function or saved by the user save function.

Recommended fiber heads

Sensing method

Sensing direction

Size

Order code

Reflective

Right-angle

M6

E32-C91N 2M

Through-beam

(Grooved type)

Array

10 mm

E32-G16 2M

Fiber amplifier connectors

Type

Cable length

No. of conductors

Applicable fiber amplifier units

Order code

Master connector

2 m

3

E3NX-CA6

E3NX-CA8

E3X-CN11

Slave connector

1

E3X-CN12

 


1.A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network.

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.