E5AR-Q43B-FLK AC100-240V 168108 E5AR1015F OMRON Temperature and Process 1 loop 2 ent salt Event 2 (V / I + V.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

E5AR-Q43B-FLK AC100-240V 168108 E5AR1015F OMRON Temperature and Process 1 loop 2 ent salt Event 2 (V / I + V..

E5AR-Q43B-FLK AC100-240V

168108

E5AR1015F

OMRON

Available Ship on today

Temperature and Process 1 loop 2 ent salt Event 2 (V / I + V) 4 RS485 alarm.SPDT

More details


Others Temperature and Processes

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Ordering information

Function

Loops

Input analog

Event Inputs

Number of outputs

Outputs

AUX outputs

Communication

Order code (96 × 96 mm)

100 to 240 VAC

24 VAC/DC

standard

1

1

2

2

QC,Q

4R

-

E5AR-Q4B AC100-240

E5AR-Q4B AC/DC24

standard

1

1

2

2

QC,Q

4R

RS-485

E5AR-Q43B-FLK AC100-240V

standard

1

1

6

2

QC,Q

4R

RS-485

E5AR-Q43DB-FLK AC100-240V

standard

1

1

6

4

QC,Q,C,C

4R

RS-485

E5AR-QC43DB-FLK AC100-240

E5AR-QC43DB-FLK AC/DC24

standard

max 2

2

4

2

QC,Q

4R

RS-485

E5AR-Q43DW-FLK AC100-240V

standard

max 2

2

4

4

QC,Q,QC,Q

4R

RS-485

E5AR-QQ43DW-FLK AC100-240

E5AR-QQ43DW-FLK AC/24

standard

max 4

4

4

4

QC,Q,QC,Q

4R

RS-485

E5AR-QQ43DWW-FLK AC100-240V

standard

1

1

2

2

C,C

4R

-

E5AR-C4B AC100-240

E5AR-C4B AC/DC24

standard

1

1

2

2

C,C

4R

RS-485

E5AR-C43B-FLK AC100-240V

standard

1

1

6

2

C,C

4R

RS-485

E5AR-C43DB-FLK AC100-240V

standard

max 2

2

4

2

C,C

4R

RS-485

E5AR-C43DW-FLK AC100-240V

standard

max 4

4

4

4

C,C,C,C

4R

RS-485

E5AR-CC43DWW-FLK AC100-240

E5AR-CC43DWW-FLK AC/DC24

valve

1

1 + pot

4

2

R,R

4R

-

E5AR-PR4DF AC100-240

E5AR-PR4DF AC/DC24

valve

1

1 + pot

4

4

R,R,QC,Q

4R

RS-485

E5AR-PRQ43DF-FLK AC100-240

E5AR-PRQ43DF-FLK AC/DC24

standard

1

1

2

2

QC,Q

4R

DeviceNet

E5AR-Q4B-DRT AC100-240V

E5AR-Q4B-DRT AC24V

standard

1

1

2

4

QC,Q,C,C

4R

DeviceNet

E5AR-QC4B-DRT AC100-240V

E5AR-QC4B-DRT AC24V

standard

max 2

2

-

4

QC,Q,QC,Q

4R

DeviceNet

E5AR-QQ4W-DRT AC100-240V

E5AR-QQ4W-DRT AC24V

standard

1

1

2

2

C,C

4R

DeviceNet

E5AR-C4B-DRT AC100-240V

E5AR-C4B-DRT AC24V

standard

max 4

4

-

4

C,C,C,C

4R

DeviceNet

E5AR-CC4WW-DRT AC100-240V

valve

1

1 + pot

-

2

R,R

4R

DeviceNet

E5AR-PR4F-DRT AC100-240V

E5AR-PR4F-DRT AC24V

valve

1

1 + pot

-

4

R,R,QC,Q

4R

DeviceNet

E5AR-PRQ4F-DRT AC100-240V

E5AR-PRQ4F-DRT AC24V

SV programmer

1

1

2

2

QC,Q

4R

-

E5AR-TQ4B AC100-240

E5AR-TQ4B AC/DC24

SV programmer

1

1

2

2

C,C

4R

-

E5AR-TC4B AC100-240

E5AR-TC4B AC/DC24

SV programmer

1

1

2

2

QC,Q

4R

RS-485

E5AR-TQ43B-FLK AC100-240

SV programmer

1

1

2

2

C,C

4R

RS-485

E5AR-TC43B-FLK AC100-240

SV programmer

1

1

10

2

QC,Q

10T

RS-485

E5AR-TQE3MB-FLK AC100-240

SV programmer

1

1

10

2

C,C

10T

RS-485

E5AR-TCE3MB-FLK AC100-240

SV programmer

1

1

10

4

QC,Q,C,C

10T

RS-485

E5AR-TQCE3MB-FLK AC100-240V

E5AR-TQCE3MB-FLK AC/DC24

SV programmer

max 2

2

4

2

QC,Q

4R

RS-485

E5AR-TQ43DW-FLK AC100-240

SV programmer

max 2

2

4

2

C,C

4R

RS-485

E5AR-TC43DW-FLK AC100-240

SV programmer

max 2

2

8

4

QC,Q,QC,Q

10T

RS-485

E5AR-TQQE3MW-FLK AC100-240

E5AR-TQQE3MW-FLK AC/DC24

SV programmer

max 4

4

8

2

C,C,C,C

10T

RS-485

E5AR-TCCE3MWW-FLK AC100-240

E5AR-TCCE3MWW-FLK AC/DC24

SV programmer

max 4

4

8

4

QC,Q,QC,Q

10T

RS-485

E5AR-TQQE3MWW-FLK AC100-240

SV programmer + valve

1

1 + pot

4

2

R,R

4R

-

E5AR-TPR4DF AC100-240

E5AR-TPR4DF AC/DC24

SV programmer + valve

1

1 + pot

8

4

R,R,QC,Q

10T

RS-485

E5AR-TPRQE3MF-FLK AC100-240

E5AR-TPRQE3MF-FLK AC/DC24

  • Note • Standard = heat and/or cool PID control, valve = valve positioning (relay up/down) (PRR)
  • • max 2 = 2 loops heat and/or cool or 1 loop cascade, ratio or remote SP
  • • max 4 = 4 loops heat and/or cool
  • • 1, 2 or 4 = number of analog universal input 1 + pot = 1 universal and 1 slide wire feedback from valve
  • • QC = voltage (pulse) or current (switch), Q = voltage (pulse), C = current, 4R = 4 two pole relay, 2T = two transistor output NPN

 

Function

Loops

Input analog

Event Inputs

Number of outputs

Outputs

AUX outputs

Communication

Order code (48 × 96 mm)

100 to 240 VAC

24 VAC/DC

standard

1

1

2

2

QC+Q

4R

-

E5ER-Q4B AC100-240

E5ER-Q4B AC/DC24

standard

1

1

2

2

QC+Q

4R

RS-485

E5ER-Q43B-FLK AC100-240V

standard

1

1

2

4

QC+Q+C+C

4R

RS-485

E5ER-QC43B-FLK AC100-240

E5ER-QC43B-FLK AC/DC24

standard

1

1

6

2

QC+Q

2T

RS-485

E5ER-QT3DB-FLK AC100-240V

standard

max 2

2

4

2

QC+Q

2T

RS-485

E5ER-QT3DW-FLK AC100-240

E5ER-QT3DW-FLK AC/DC24

standard

1

1

2

2

C+C

4R

-

E5ER-C4B AC100-240

E5ER-C4B AC/DC24

standard

1

1

2

2

C+C

4R

RS-485

E5ER-C43B-FLK AC100-240V

standard

1

1

6

2

C+C

2T

RS-485

E5ER-CT3DB-FLK AC100-240V

standard

max 2

2

4

2

C+C

2T

RS-485

E5ER-CT3DW-FLK AC100-240

E5ER-CT3DW-FLK AC/DC24

valve

1

1 + pot

4

2

R+R

2T

-

E5ER-PRTDF AC100-240

E5ER-PRTDF AC/DC24

valve

1

1 + pot

-

4

R+R+QC+Q

4R

RS-485

E5ER-PRQ43F-FLK AC100-240

E5ER-PRQ43F-FLK AC/DC24

standard

1

1

2

2

QC+Q

2T

DeviceNet

E5ER-QTB-DRT AC100-240V

E5ER-QTB-DRT AC24V

standard

max 2

2

-

2

QC+Q

2T

DeviceNet

E5ER-QTW-DRT AC100-240V

E5ER-QTW-DRT AC24V

standard

1

1

2

2

C+C

2T

DeviceNet

E5ER-CTB-DRT AC100-240V

E5ER-CTB-DRT AC24V

standard

max 2

2

-

2

C+C

2T

DeviceNet

E5ER-CTW-DRT AC100-240V

E5ER-CTW-DRT AC24V

valve

1

1 + pot

-

2

R+R

2T

DeviceNet

E5ER-PRTF-DRT AC100-240V

E5ER-PRTF-DRT AC24V

SV programmer

1

1

2

2

QC+Q

4R

-

E5ER-TQ4B AC100-240

E5ER-TQ4B AC/DC24

SV programmer

1

1

2

2

C+C

4R

-

E5ER-TC4B AC100-240

E5ER-TC4B AC/DC24

SV programmer

1

1

2

2

QC+Q

4R

RS-485

E5ER-TQC43B-FLK AC100-240

E5ER-TQC43B-FLK AC/DC24

SV programmer

max 2

2

4

2

QC+Q

2T

RS-485

E5ER-TQT3DW-FLK AC100-240

E5ER-TQT3DW-FLK AC/DC24

SV programmer

max 2

2

4

2

C+C

2T

RS-485

E5ER-TCT3DW-FLK AC100-240

E5ER-TCT3DW-FLK AC/DC24

SV programmer + valve

1

1 + pot

4

2

R+R

2T

-

E5ER-TPRTDF AC100-240

E5ER-TPRTDF AC/DC24

SV programmer + valve

1

1 + pot

-

3

R+R+QC

4R

RS-485

E5ER-TPRQ43F-FLK AC100-240

E5ER-TPRQ43F-FLK AC/DC24

  • Note • Standard = heat and/or cool PID control, valve = valve positioning (relay up/down) (PRR)
  • • max 2 = 2 loops heat and/or cool or 1 loop cascade, ratio or remote SP
  • • max 4 = 4 loops heat and/or cool
  • • 1, 2 or 4 = number of analog universal input 1 + pot = 1 universal and 1 slide wire feedback from valve
  • • QC = voltage (pulse) or current (switch), Q = voltage (pulse), C = current, 4R = 4 two pole relay, 2T = two transistor output NPN

Accessories

Terminal covers

Order code

Terminal cover for E5AR

E53-COV14

Terminal cover for E5ER

E53-COV15

E5_R/E5_R-T optional tools

 

Option

Order code

PC based configuration and tuning software CX-Thermo

EST2-2C-MV4

Specifications

Item

 

Thermocouple input type

K, J, T, E, L, U, N, R, S, B, W

RTD input type

Pt100

Linear input type

mA, V

Control mode

2-PID or ON/OFF control

Accuracy

±0.1% FS

Auto-tuning

yes

RS-485

optional

Event input

optional

Ambient temperature

-10 to 55°C

IP rating front panel

IP66

Sampling period

50 ms

Size in mm (H×W×D)

E5ER: 96×48×110
E5AR: 96×96×110

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.