DRT2-OD08 231468 OMRON E / S Remote, Module 8 NPN View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DRT2-OD08 231468 OMRON E / S Remote, Module 8 NPN

DRT2-OD08

231468

OMRON

Available

Ship on today

E / S Remote, Module 8 NPN

More details


Programmable Logic Controllers Plcs

Remote I/O

DRT (Devicenet)

* Brand new produt in its original packing covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Compact I/O DRT2 RemoteI/O
Smart DeviceNet I/O
Compact DeviceNet I/O units with extensivediagnosticfunctions.Data regarding
power supply status, I/O responsetimes, operationcountersand on-timeare contin- uously recorded and checked against user-defined limits. Any deviation is reportedto the control system, as indication to perform machine maintenance and prevent un-
planned downtime. Smart DeviceNet I/Os are supportedby PLC FunctionBlocks and HMI Smart Active Parts, allowing program-less visualisation and monitoring from the CJ1 PLCs andNS operator terminals.
• Compact size IP20 housing
• Expandable digital I/Os
• Built-in diagnostics and preventive maintenance functions
• DetachableI/O terminal blocks
• Analog I/O with data pre-processing and alarm functions
Ordering information
Unit typeSpecifications Size in mm
(H×W×D)
Remarks Order code
8-pointPNP input unit24 VDC, 6 mA per point50×115×50– DRT2-ID08-1
16-point PNP input unit24 VDC, 6 mA per point50×115×50Expandable with one XWT unitDRT2-ID16-1
16-point PNP input unit24 VDC, 6 mA per point50×180×583-tier connection for direct sensor wiring DRT2-ID16TA-1
8-pointPNP output unit24 VDC, 0.5 A per point50×115×50– DRT2-OD08-1
16-point PNP output unit24 VDC, 0.5 A per point50×115×50Expandable with one XWT unitDRT2-OD16-1
16-point PNP output unit24 VDC, 0.5 A per point 50×180×583-tier connection for direct actuator wiringDRT2-OD16TA-1
16-point relay output unit2 A per point, max. 8 A per common 50×125×52with easy-to-replace relays, expandable with one XWT
unit
DRT2-ROS16
8-point input + 8-point output unit (PNP)24 VDC, input 6 mA, output 0.5 A per point 50×115×50– DRT2-MD16-1
8-point input + 8-point output unit (PNP)24 VDC, input 6 mA, output 0.5 A per point 50×180×583-tier connection for direct sensor/actuator wiringDRT2-MD16TA-1
4-Channel analog input unit 0 to 5 V, 1 to 5 V, 0 to 10 V, -10to 10 V, 0 to 20 mA,
4 to 20 mA
4-Channel analog input unit 1 to 5 V, 1 to 5 V, 0 to 10 V, -10to 10 V, 0 to 20 mA,
4 to 20 mA
2-Channel analog output unit 0 to 5 V, 1 to 5 V, 0 to 10 V, -10to 10 V, 0 to 20 mA,
4 to 20 mA
50×115×50Resolution 1/6000, conversion time 4 ms (4 inputs) DRT2-AD04
50×115×50Resolution 1/30000, conversion time 250 ms (4 inputs) DRT2-AD04H
50×115×50Resolution 1/6000, conversion time 2 ms (2 outputs) DRT2-DA02
4-Channel temperature input unitPlatinum Resistance Thermometer types Pt100, JPt100 50×115×500.3% accuracy, conversion time 250 ms (4 inputs)DRT2-TS04P
4-Channel temperature input unitThermocouple types R, S, K, J, T, B, L, E, U, N, W, and PL2
50×115×500.3% accuracy, conversion time 250 ms (4 inputs)DRT2-TS04T
Expansion units
Unit typeSpecifications Size in mm
(H×W×D)
Remarks Order code
8-pointPNP input expansion unit 24 VDC, 6 mA per point50×66×50Expansion unit for GX, DRT2 and CRT1 seriesXWT-ID08-1
16-point PNP input expansion unit 24 VDC, 6 mA per point50×94×50Expansion unit for GX, DRT2 and CRT1 seriesXWT-ID16-1
8-pointPNP output expansion unit 24 VDC, 0.5 A per point50×66×50Expansion unit for GX, DRT2 and CRT1 seriesXWT-OD08-1
16-point PNP output expansion unit 24 VDC, 0.5 A per point50×94×50Expansion unit for GX, DRT2 and CRT1 series XWT-OD16-1
Note:To order models with NPN (sinking) outputs and corresponding inputs (+V common),omit the “-1” from the model code.
Accessories
TypeOrder code
Power supply tap with 2 fuses, 2 bus connectors and termination resistor DCN1-1P T-branch tap with 3 bus connectors (screw clamp) and terminating resistorDCN1-1C
T-branch tap with 3 bus connectors (screwless) DCN1-1NC T-branch tap with 5 bus connectors (screw clamp) and terminating resistorDCN1-3C
T-branch tap with 5 bus connectors (screwless) DCN1-3NC
Terminating resistor with screw terminals DRS1-T
53

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoDeviceNet remote terminal, 8x transistor outputs, NPN, 0.5A, 24 VDC - OMRON - DRT2-OD08 - 231468English170 Kbytespdf1-mostradoDeviceNet remote terminal, 8x transistor outputs, NPN, 0.5A, 24 VDC - OMRON - DRT2-OD08 - 231468
pdf1-DeviceNet remote terminal, 8x transistor outputs, NPN, 0.5A, 24 VDC - OMRON - DRT2-OD08 - 231468English23 Mbytespdf1-mostradoDeviceNet remote terminal, 8x transistor outputs, NPN, 0.5A, 24 VDC - OMRON - DRT2-OD08 - 231468
pdf2-mostradoDeviceNet remote terminal, 8x transistor outputs, NPN, 0.5A, 24 VDC - OMRON - DRT2-OD08 - 231468English157 Kbytespdf1-mostradoDeviceNet remote terminal, 8x transistor outputs, NPN, 0.5A, 24 VDC - OMRON - DRT2-OD08 - 231468
pdf2-DeviceNet remote terminal, 8x transistor outputs, NPN, 0.5A, 24 VDC - OMRON - DRT2-OD08 - 231468English3 Mbytespdf1-mostradoDeviceNet remote terminal, 8x transistor outputs, NPN, 0.5A, 24 VDC - OMRON - DRT2-OD08 - 231468
pdf3-DeviceNet remote terminal, 8x transistor outputs, NPN, 0.5A, 24 VDC - OMRON - DRT2-OD08 - 231468English4 Mbytespdf1-mostradoDeviceNet remote terminal, 8x transistor outputs, NPN, 0.5A, 24 VDC - OMRON - DRT2-OD08 - 231468
pdf4-DeviceNet remote terminal, 8x transistor outputs, NPN, 0.5A, 24 VDC - OMRON - DRT2-OD08 - 231468English3 Mbytespdf1-mostradoDeviceNet remote terminal, 8x transistor outputs, NPN, 0.5A, 24 VDC - OMRON - DRT2-OD08 - 231468
pdf5-DeviceNet remote terminal, 8x transistor outputs, NPN, 0.5A, 24 VDC - OMRON - DRT2-OD08 - 231468English5 Mbytespdf1-mostradoDeviceNet remote terminal, 8x transistor outputs, NPN, 0.5A, 24 VDC - OMRON - DRT2-OD08 - 231468

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review