Setting range

Power supply voltage

Output

Order code

2 to 20 mA AC/DC,
10 to 100 mA AC/DC,
50 to 500 mA AC/DC

24 VAC/DC

Relay: SPDT contact output

K8DT-AS1CD

Transistor: Open collector

K8DT-AS1TD

100 to 240 VAC

Relay: SPDT contact output

K8DT-AS1CA

Transistor: Open collector

K8DT-AS1TA

0.1 to 1 A AC/DC,
0.5 to 5 A AC/DC

24 VAC/DC

Relay: SPDT contact output

K8DT-AS2CD

Transistor: Open collector

K8DT-AS2TD

100 to 240 VAC

Relay: SPDT contact output

K8DT-AS2CA

Transistor: Open collector

K8DT-AS2TA

10 to 100 A AC ,
20 to 200 A AC

24 VAC/DC

Relay: SPDT contact output

K8DT-AS3CD

Transistor: Open collector

K8DT-AS3TD

100 to 240 VAC

Relay: SPDT contact output

K8DT-AS3CA

Transistor: Open collector

K8DT-AS3TA

Accessories

Omron CT

Input range

Applicable relay

Order code

 

 

10 to 100 A AC, 20 to 200 A AC

K8AK-AS3

K8AC-CT200L

Commercially Available CTs

CT current on secondary side

Applicable Relay

 

0 to 1 A AC,

0 to 5 A AC

K8DT-AS2

Front Cover (Order separately)

Order code

 

Y92A-D1A

Specifications

Item

K8DT-AS1

K8DT-AS2

K8DT-AS3

Power supply voltage

K8DT-AS__D

24 VAC 50/60 Hz, 24 VDC

K8DT-AS__A

100 to 240 VAC 50/60 Hz

Power consumption

24 VAC/DC: 1.8 VA/1 W max.

100 to 240 VAC: 2.5 VA max.

Operate (SV)

Operating value setting range

10% to 100% of the maximum value of the setting range

2 to 20 mA AC/DC

10 to 100 mA AC/DC

50 to 500 mA AC/DC

10% to 100% of the maximum value of the setting range

0.1 to 1 A AC/DC (Compatible with commercially available CTs.)

0.5 to 5 A AC/DC (Compatible with commercially available CTs.)

10% to 100% of the maximum value of the setting range

When used with the OMRON CT (K8AC-CT200L).

10 to 100 A AC

20 to 200 A AC

Operating value

100% operation at set value

Reset (HYS)

Hysteresis

5% to 50% of operating value

Resetting method

Manual reset/automatic reset (switchable)

Operating time setting range (T)

0.1 to 30 s

Startup lock time setting range (LOCK)

0 to 30 s (The startup lock timer starts when the input has reached approximately 30% or more of the set value.)

Indicators

Power (PWR): Green, Output (OUT): Yellow, Alarm outputs (ALM): Red

Output form

Relay: SPDT contact output

Transistor: Open collector

Switchable between normally open and normally closed with a DIP switch setting.

Output relays ratings

Resistive load

250 VAC 5 A or 30 VDC 5 A

Inductive load

250 VAC 1 A,
48 VDC 0.2 A

Minimum load

5 VDC, 10 mA (reference values)

Mechanical life

10 million operations min.

Electrical life

5 A at 250 VAC or 30 VDC: 50,000 operations

3 A at 250 VAC or 30 VDC:100,000 operation

Transistor output ratings

Contact form

SPST-NO (Open collector)

Rated voltage

24 VDC (maximum voltage: 26.4 VDC)

Maximum current

50 mA DC

Ambient operating temperature

-20 to 60°C (with no condensation or icing)

Storage temperature

-25 to 65°C (with no condensation or icing)

Case material

PC, UL 94 V-0

Weight

Approx. 100 g

Size in mm (H × W × D)

90×17.5×90

Operating voltage range

85% to 110% of power supply voltage

Rated power supply frequency

50/60 Hz ±5 Hz

Input frequency range

DC input or AC input (45 to 65 Hz)

AC input (45 to 65 Hz)

Overload capacity

Continuous input at 120% of maximum input, 1 s at 150%

Continuous input at 120%, 30 s at 200%, and 1 s at 600% with an OMRON CT (K8AC-CT200L)

Repeat error

Operating value

±0.5% full scale (at 25°C and 65% humidity, rated power supply voltage)

Operating time

±50 ms (at 25°C and 65% humidity, rated power supply voltage)

Applicable standards

Conforming standards

EN 60947-5-1

Installation environment (pollution level 2, Overvoltage category III)

EMC

EN 60947-5-1

Safety standards

UL 60947-5-1 (Listing), Korean Radio Waves Act (Act 10564), CCC (GB14048.5)

Degree of protection

Terminals: IP20


1.The K8DT-AS3__ is designed to be used in combination with an OMRON K8AC-CT200L Current Transformer (CT). (Direct input is not possible.)

2.Enabled only for overcurrent operation.

3.Overload capacity of primary side of CT.

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.