ANUNCIAR
CS1D-CPU67HA CS1D0070A CS1DCPU67HA OMRON CPU for duplex system, 250K steps program, 448K words data memory, .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CS1D-CPU67HA CS1D0070A CS1DCPU67HA OMRON CPU for duplex system, 250K steps program, 448K words data memory, ..

CS1D-CPU67HA

CS1D0070A

CS1DCPU67HA

OMRON

CPU for duplex system, 250K steps program, 448K words data memory, 7 duplex expansion racks max, hot standby CPUs, hot swap I/O. Support FB and ST programming language

More details


PLC's > PLC CPU-module

Control Systems > CS1

Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

Total: $13,597.04
Unit price: $13,597.04
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



  • Choose the level of redundancy needed; CPU, power supply, communication
  • No special programming or software tools required
  • Hot-swapping of I/O units
  • All standard CS1 I/O units can be mounted
  • Ideal for control of power generators, water supply utilities, 24/7 production.

Specifications & ordering info

Ordering information

Max. Digital I/O points

Program capacity

Data memory capacity

Logic execution speed

Max. I/O units

Additional functions

Order code

5120

250K steps

448K words

20 ns

80

-

CS1H-CPU67H

71

Supports duplex power supply and I/O hot-swapping

CS1D-CPU67S

68

CPU for full dual-redundancy

CS1D-CPU67H

CPU for full dual-redundancy, with loop control board

CS1D-CPU67P

120K steps

256K words

80

-

CS1H-CPU66H

60K steps

128K words

80

-

CS1H-CPU65H

71

Supports duplex power supply and I/O hot-swapping

CS1D-CPU65S

68

CPU for full dual-redundancy

CS1D-CPU65H

CPU for full dual-redundancy, with loop control board

CS1D-CPU65P

30K steps

64K words

80

-

CS1H-CPU64H

20K steps

-

CS1H-CPU63H

60K steps

40 ns

-

CS1G-CPU45H

1280

30K steps

40

-

CS1G-CPU44H

35

Supports duplex power supply and I/O hot-swapping

CS1D-CPU44S

960

20K steps

30

-

CS1G-CPU43H

10K steps

-

CS1G-CPU42H

26

Supports duplex power supply and I/O hot-swapping

CS1D-CPU42S

Accessories

Description

Remarks

Order code

High-speed data collection and storage unit, with CF card slot and Ethernet port

CPU bus unit

CS1W-SPU01-V2

High-speed data collection and storage unit, with CF card slot and 2 Ethernet ports

CPU bus unit

CS1W-SPU02-V2

Duplex unit, required for CS1D-CPU6_H systems

-

CS1D-DPL01

Serial communication option board, 2 x RS-232C

-

CS1W-SCB21-V1

Serial communication option board, 1 x RS-232C + 1 x RS422/RS-485

-

CS1W-SCB41-V1

Loop control option board

50 control blocks max.

CS1W-LCB01

Loop control option board

300 control blocks max.

CS1W-LCB05

Replacement battery set, for all CS1 CPUs

-

CS1W-BAT01

Compact Flash memory card, 128 MB, for all models (not required for operation)

Industrial grade

HMC-EF183

Compact Flash memory card, 256 MB, for all models (not required for operation)

Industrial grade

HMC-EF283

Compact Flash memory card, 512 MB, for all models (not required for operation)

Industrial grade

HMC-EF583

Compact Flash PC-Card adapter

-

HMC-AP001

CX-One, integrated software for programming and configuration of all Omron control system components

-

CX-ONE-AL__C-E

Connection cable, D-Sub 9-pin PC serial port to PLC peripheral port

length: 2.0 m

CS1W-CN226

Connection cable, D-Sub 9-pin PC serial port to PLC peripheral port

length: 6.0 m

CS1W-CN626

USB to serial conversion cable

-

CS1W-CIF31

Accessories

cs cpu accessories prod

ETIM for 686277 PLC's (EC000236)
Feature Name Feature Value
Model (EF000010) Modular
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Radio standard UMTS (EF008525) No
Supporting protocol for EtherCAT (EF017564) No
Appendant operation agent (Ex ib) (EF004142) No
Supporting protocol for SERCOS (EF006657) No
IO link master (EF007298) No
Rack-assembly possible (EF007018) Yes
Supporting protocol for KNX (EF003055) No
Supporting protocol for LON (EF003017) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for IEC 60870 (EF016069) No
Supporting protocol for DNP3 (EF016068) No
Radio standard GSM (EF008524) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for IEC 61850 Ethernet (EF015389) No
Suitable for rail mounting (EF003972) Yes
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
Certified for UL hazardous location class III (EF017627) No
Supporting protocol for PROFIBUS (EF003052) No
Radio standard GPRS (EF008523) No
Certified for UL hazardous location class II (EF017625) No
Certified for UL hazardous location class I (EF017622) No
Supporting protocol for DeviceNet Safety (EF007520) No
Wall mounting/direct mounting (EF007020) No
Front built-in possible (EF007016) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for SafetyBUS p (EF007527) No
Appendant operation agent (Ex ia) (EF004141) No
Supporting protocol for Modbus (EF003057) No
Redundancy (EF003156) No
Certified for UL hazardous location group G (non-conductive dusts) (EF017639) No
Supporting protocol for PROFINET CBA (EF007524) No
Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) No
Radio standard Bluetooth (EF007178) No
Suitable for safety functions (EF001597) No
Certified for UL hazardous location group E (metal dusts) (EF017637) No
With optical interface (EF003028) No
With display (EF000458) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Radio standard WLAN 802.11 (EF007179) No
Certified for UL hazardous location group A (acetylene) (EF017632) No
Certified for UL hazardous location division 2 (EF017629) No
Certified for UL hazardous location division 1 (EF017628) No
Certified for UL hazardous location group D (propane) (EF017636) No
Supporting protocol for ASI (EF003051) No
Certified for UL hazardous location group C (ethylene) (EF017635) No
Certified for UL hazardous location group B (hydrogen) (EF017633) No
Memory size (EF002997) 1936 kByte
Number of interfaces PROFINET (EF006932) 0
Number of relay outputs (EF007348) 0
Width (EF000008) 71 mm
Number of digital inputs (EF001992) 0
Depth (EF000049) 100 mm
Number of HW-interfaces wireless (EF006933) 0
Number of analogue inputs (EF001994) 0
Number of HW-interfaces parallel (EF003026) 0
Number of digital outputs (EF001993) 0
Number of analogue outputs (EF001995) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Height (EF000040) 130 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.