CJ2H-CPU68-EIP CJ2W0005F 249803 OMRON CPU 2560 I/O 400 Ksteps 832 Kw Data Ethernet/IP View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CJ2H-CPU68-EIP CJ2W0005F 249803 OMRON CPU 2560 I/O 400 Ksteps 832 Kw Data Ethernet/IP

CJ2H-CPU68-EIP

CJ2W0005F

CJ2HCPU68EIP

OMRON

CPU 2560 E/S 400 Kpasos 832 Kw Data Ethernet/IP

CPU with built-in EtherNet/IP port, 400K steps program, 32K words data memory, 32K words x 25 banks EM, 2560 I/O max, RS-232C serial port, USB program

More details


PLC's > PLC CPU-module

Control Systems > CJ1

Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

Total: $9,044.10
Unit price: $9,044.10
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Specifications

Program capacity400 K steps
Data memory capacity832 K words
Logic execution time0.016 µs
Max. number of expansion units40
Max. number of local I/O points2560
Number of built-in digital I/Os0
Communication port(s)EtherNet/IP, Ethernet TCP/IP, Serial RS-232C, USB
Height90 mm
Width80 mm
Depth74.5 mm

ETIM for 249803 PLC's (EC000236)
Feature Name Feature Value
Performance level according to EN ISO 13849-1 (EF007399) Level a
Model (EF000010) Modular
SIL according to IEC 61508 (EF009889) None
Voltage type (supply voltage) (EF002991) AC/DC
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Type of memory (EF002996) FLASH
Radio standard UMTS (EF008525) No
Supporting protocol for EtherCAT (EF017564) No
Appendant operation agent (Ex ib) (EF004142) No
Supporting protocol for other bus systems (EF003062) No
Supporting protocol for SERCOS (EF006657) No
IO link master (EF007298) No
Rack-assembly possible (EF007018) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for LON (EF003017) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for IEC 60870 (EF016069) No
Supporting protocol for EtherNet/IP (EF007521) Yes
Supporting protocol for DNP3 (EF016068) No
Radio standard GSM (EF008524) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for IEC 61850 Ethernet (EF015389) No
Suitable for rail mounting (EF003972) Yes
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
System accessory (EF004118) No
Certified for UL hazardous location class III (EF017627) No
Supporting protocol for PROFIBUS (EF003052) No
Radio standard GPRS (EF008523) No
Certified for UL hazardous location class II (EF017625) No
Certified for UL hazardous location class I (EF017622) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for TCP/IP (EF003050) Yes
Wall mounting/direct mounting (EF007020) No
Front built-in possible (EF007016) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Additional program memory possible (EF003029) No
Supporting protocol for SafetyBUS p (EF007527) No
Appendant operation agent (Ex ia) (EF004141) No
Supporting protocol for Modbus (EF003057) No
Redundancy (EF003156) No
Certified for UL hazardous location group G (non-conductive dusts) (EF017639) No
Supporting protocol for PROFINET CBA (EF007524) No
Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) No
Radio standard Bluetooth (EF007178) No
Suitable for safety functions (EF001597) No
Certified for UL hazardous location group E (metal dusts) (EF017637) No
With optical interface (EF003028) No
With display (EF000458) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Radio standard WLAN 802.11 (EF007179) No
Certified for UL hazardous location group A (acetylene) (EF017632) No
Certified for UL hazardous location division 2 (EF017629) No
Certified for UL hazardous location division 1 (EF017628) No
Certified for UL hazardous location group D (propane) (EF017636) No
Supporting protocol for ASI (EF003051) No
Certified for UL hazardous location group C (ethylene) (EF017635) No
Certified for UL hazardous location group B (hydrogen) (EF017633) No
Number of HW-interfaces other (EF003027) 1
Memory size (EF002997) 3300 kByte
Number of interfaces PROFINET (EF006932) 0
Number of relay outputs (EF007348) 0
Number of HW-interfaces USB (EF003025) 1
Width (EF000008) 80 mm
Number of digital inputs (EF001992) 0
Depth (EF000049) 74.5 mm
Number of HW-interfaces wireless (EF006933) 0
Number of analogue inputs (EF001994) 0
Number of HW-interfaces parallel (EF003026) 0
Number of digital outputs (EF001993) 0
Number of HW-interfaces industrial Ethernet (EF003020) 1
Number of analogue outputs (EF001995) 0
Number of HW-interfaces RS-232 (EF003021) 1
Number of HW-interfaces RS-422 (EF003022) 0
Processing time (1K, binary operation) (EF003004) 0.016 ms
Number of HW-interfaces RS-485 (EF003023) 0
Height (EF000040) 90 mm
Max. number of time switches (EF007349) 4090
Supply voltage AC 60 Hz (EF007533) 85 V
Supply voltage DC (EF007534) 24 V
Supply voltage AC 50 Hz (EF007532) 85 V

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.