Product successfully added to your shopping cart
CP1E-NA20DR-A
CP1W0115E
CP1ENA20DRA
OMRON
1
CPU 12/8 I/O AC Relay Outputs 2/1 Analog I/O
PLC, 100-240 VAC supply, 12 x 24 VDC inputs, 8 x relay outputs 2 A, 2 x analog inputs, 1 x analog output, resolution 1/6000, 8K steps program + 8K wor
PLC's > PLC CPU-module
Control Systems > CPM2C
Brand new product in its original packaging covered by the warranties and certifications provided by OMRON
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Supply voltage type | AC |
| Number of digital inputs | 12 |
| Input type | PNP/NPN |
| Number of digital outputs | 8 |
| Output type | Relay |
| Program capacity | 8 K steps |
| Data memory capacity | 8 K words |
| Logic execution time | 1.19 µs |
| Communication port(s) | Serial RS-232C, USB |
| Number of Ethernet ports | 0 |
| Number of USB ports | 1 |
| Number of RS-232 ports | 1 |
| Number of RS-485 ports | 0 |
| Communication option(s) | CompoBus/S Slave, Ethernet TCP/IP, Serial RS-232C, Serial RS-422, Serial RS-485 |
| Max. encoder input frequency | 100 kHz |
| Max. number of PTP axes | 0 |
| Max. pulse output frequency | 0 kHz |
| Function Block programming | |
| Battery-free memory backup | |
| Real-time clock | |
| Analogue option boards | |
| Max. number of analogue I/O channels | 31 |
| Max. number of local I/O points | 140 |
| Max. number of expansion units | 3 |
| Built-in auxiliary 24 VDC output | 300 mA |
| Operating temperature range | 0-55 °C |
| Product Height (unpacked) | 90 mm |
| Product Width (unpacked) | 130 mm |
| Product Depth (unpacked) | 85 mm |
| Product Weight (unpacked) | 700 g |
| CP1W-BAT01 | Battery for the CP1 PLC | ||
| CP1W-CIF01 | CP1 RS-232C (15 m max.) serial communication option board | ||
| CP1W-CIF11 | CP1 RS422/485 (50 m max.) serial communication option board | ||
| CP1W-CIF12-V1 | CP1 RS422/485 (isolated 500 m max.) serial communication option board | ||
| CP1W-CIF41 | CP1 Ethernet communications option, 1 x RJ45 socket | ||
| CP1W-CN221 | USB Programming cable, A-type male to B-type male, 1.8 m | ||
| CP1W-CN811 | I/O expansion cable for CP1-series, 80 cm | ||
| CXONE-LT01-EV4 | CX-One Lite v4.x software, for Windows 2000/XP/Vista, single-user licence only, (requires CDs, CXOne-LTCD-EV4), limited to program the CPx PLC platform |
| Feature Name | Feature Value |
|---|---|
| Performance level according to EN ISO 13849-1 (EF007399) | Level a |
| Model (EF000010) | Compact |
| SIL according to IEC 61508 (EF009889) | None |
| Voltage type (supply voltage) (EF002991) | AC |
| Explosion safety category for gas (EF003997) | None |
| Explosion safety category for dust (EF003998) | None |
| Type of memory (EF002996) | FLASH |
| Radio standard UMTS (EF008525) | No |
| Supporting protocol for EtherCAT (EF017564) | No |
| Appendant operation agent (Ex ib) (EF004142) | No |
| Supporting protocol for other bus systems (EF003062) | Yes |
| Supporting protocol for SERCOS (EF006657) | No |
| IO link master (EF007298) | No |
| Rack-assembly possible (EF007018) | No |
| Supporting protocol for KNX (EF003055) | No |
| Supporting protocol for LON (EF003017) | No |
| Supporting protocol for SUCONET (EF003060) | No |
| Supporting protocol for IEC 60870 (EF016069) | No |
| Supporting protocol for EtherNet/IP (EF007521) | No |
| Supporting protocol for DNP3 (EF016068) | No |
| Radio standard GSM (EF008524) | No |
| Supporting protocol for INTERBUS (EF003054) | No |
| Supporting protocol for Data-Highway (EF003058) | No |
| Supporting protocol for PROFINET IO (EF007525) | No |
| Supporting protocol for DeviceNet (EF003059) | No |
| Supporting protocol for IEC 61850 Ethernet (EF015389) | No |
| Suitable for rail mounting (EF003972) | Yes |
| Supporting protocol for INTERBUS-Safety (EF006662) | No |
| Supporting protocol for PROFIsafe (EF007526) | No |
| System accessory (EF004118) | No |
| Certified for UL hazardous location class III (EF017627) | No |
| Supporting protocol for PROFIBUS (EF003052) | No |
| Radio standard GPRS (EF008523) | No |
| Certified for UL hazardous location class II (EF017625) | No |
| Certified for UL hazardous location class I (EF017622) | No |
| Supporting protocol for DeviceNet Safety (EF007520) | No |
| Supporting protocol for TCP/IP (EF003050) | No |
| Wall mounting/direct mounting (EF007020) | Yes |
| Front built-in possible (EF007016) | No |
| Supporting protocol for Foundation Fieldbus (EF007522) | No |
| Additional program memory possible (EF003029) | No |
| Supporting protocol for SafetyBUS p (EF007527) | No |
| Appendant operation agent (Ex ia) (EF004141) | No |
| Supporting protocol for Modbus (EF003057) | No |
| Redundancy (EF003156) | No |
| Certified for UL hazardous location group G (non-conductive dusts) (EF017639) | No |
| Supporting protocol for PROFINET CBA (EF007524) | No |
| Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) | No |
| Radio standard Bluetooth (EF007178) | No |
| Suitable for safety functions (EF001597) | No |
| Certified for UL hazardous location group E (metal dusts) (EF017637) | No |
| With optical interface (EF003028) | No |
| With display (EF000458) | No |
| Supporting protocol for CAN (EF003053) | No |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | No |
| Radio standard WLAN 802.11 (EF007179) | No |
| Certified for UL hazardous location group A (acetylene) (EF017632) | No |
| Certified for UL hazardous location division 2 (EF017629) | No |
| Certified for UL hazardous location division 1 (EF017628) | No |
| Certified for UL hazardous location group D (propane) (EF017636) | No |
| Supporting protocol for ASI (EF003051) | No |
| Certified for UL hazardous location group C (ethylene) (EF017635) | No |
| Certified for UL hazardous location group B (hydrogen) (EF017633) | No |
| Number of HW-interfaces other (EF003027) | 0 |
| Memory size (EF002997) | 52 kByte |
| Number of interfaces PROFINET (EF006932) | 0 |
| Number of relay outputs (EF007348) | 8 |
| Number of HW-interfaces USB (EF003025) | 1 |
| Width (EF000008) | 130 mm |
| Number of digital inputs (EF001992) | 12 |
| Depth (EF000049) | 85 mm |
| Number of HW-interfaces wireless (EF006933) | 0 |
| Number of analogue inputs (EF001994) | 2 |
| Number of HW-interfaces parallel (EF003026) | 0 |
| Number of digital outputs (EF001993) | 8 |
| Number of HW-interfaces industrial Ethernet (EF003020) | 0 |
| Number of analogue outputs (EF001995) | 1 |
| Number of HW-interfaces RS-232 (EF003021) | 1 |
| Number of HW-interfaces RS-422 (EF003022) | 0 |
| Processing time (1K, binary operation) (EF003004) | 1.1 ms |
| Number of HW-interfaces RS-485 (EF003023) | 0 |
| Height (EF000040) | 90 mm |
| Max. number of time switches (EF007349) | 255 |
| Supply voltage AC 60 Hz (EF007533) | 85 V |
| Supply voltage AC 50 Hz (EF007532) | 85 V |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGO OMRON AUTOMATION EN.pdf | 19 Mbytes |
|
| PDF CATALOG OMRON 2024 EN.pdf | 25 Mbytes |
|
| CP1E-NA20DR-A CP1ENA20DRA CP1W0115E cp1e_brochure_en.pdf | 3 Mbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.