EJ1C-EDUA-NFLK 225933 OMRON Temperature Control Panel, EJ1 Header Alim, Coms, Alarm View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EJ1C-EDUA-NFLK 225933 OMRON Temperature Control Panel, EJ1 Header Alim, Coms, Alarm

EJ1C-EDUA-NFLK

225933

OMRON

Available

Ship on today

Temperature Control Panel, EJ1 Header Alim, Coms, Alarm

More details


Temperature Sensors

EJ1

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

Quantity Price
1+$184.17
2+$177.55
4+$172.38
5+$170.98
7+$169.58
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Ordering information

Type

Control points

Control outputs

Auxiliary outputs

Other functions

Terminal

Order code

Basic unit

2

2 voltage (pulse)

2 transistor (NPN)

2 CT input + 2 event input

M3 screws

EJ1N-TC2A-QNHB

Basic unit

2

2 voltage (pulse)

2 transistor (NPN)

2 CT input + 2 event input

Screw-less clamp

EJ1N-TC2B-QNHB

Basic unit

2

2 current

2 transistor (NPN)

2 event input

M3 screws

EJ1N-TC2A-CNB

Basic unit

2

2 current

2 transistor (NPN)

2 event input

Screw-less clamp

EJ1N-TC2B-CNB

Basic unit

4

4 voltage (pulse)

-

-

M3 screws

EJ1N-TC4A-QQ

Basic unit

4

4 voltage (pulse)

-

-

Screw-less clamp

EJ1N-TC4B-QQ

High function unit

-

-

4 transistor (NPN)

4 event input

M3 screws

EJ1N-HFUA-NFLK

High function unit

-

-

4 transistor (NPN)

4 event input

Screw-less clamp

EJ1N-HFUB-NFLK

DeviceNet unit

-

-

-

-

Screw connector

EJ1N-HFUB-DRT

Ethernet unit

-

-

-

-

3 x RJ45

EJ1N-HFU-ETN

End unit

-

-

2 transistor (NPN)

-

M3 screws

EJ1C-EDUA-NFLK

End unit

-

-

2 transistor (NPN)

-

Removable Connector

EJ1C-EDUC-NFLK

 

Type

Control points

Control outputs

Auxiliary outputs

Other functions

Terminal

Order code

Basic unit

2 (GTC)

2 voltage (pulse)

2 transistor (NPN)

2 CT input

M3 screws

EJ1G-TC2A-QNH

Basic unit

2 (GTC)

2 voltage (pulse)

2 transistor (NPN)

2 CT input

Screw-less clamp

EJ1G-TC2B-QNH

Basic unit

4 (GTC)

4 voltage (pulse)

-

-

M3 screws

EJ1G-TC4A-QQ

Basic unit

4 (GTC)

4 voltage (pulse)

-

-

Screw-less clamp

EJ1G-TC4B-QQ

High function unit

- (GTC)

-

4 transistor (NPN)

-

M3 screws

EJ1G-HFUA-NFLK

High function unit

- (GTC)

-

4 transistor (NPN)

-

Screw-less clamp

EJ1G-HFUB-NFLK

End unit

-

-

2 transistor (NPN)

-

M3 screws

EJ1C-EDUA-NFLK

End unit

-

-

2 transistor (NPN)

-

Removable Connector

EJ1C-EDUC-NFLK

Accessories

Current transformer

Diameter

Order code

5.8 dia.

E54-CT1

12.0 dia.

E54-CT3

Communications and cables

Description

Order code

G3ZA connecting cable 5 meter

EJ1C-CBLA050

USB programming cable

E58-CIFQ1

PC based configuration and tuning software CX-Thermo

EST2-2C-MV4

PROFIBUS Gateway

PRT1-SCU11

Specifications

Item

Type

EJ1_-TC2

EJ1_-TC4

Power supply voltage

24 VDC

Operating voltage range

85% to 110% of rated voltage

Power consumption

4 W max. (at maximum load)

5 W max. (at maximum load)

Input (see note)

Thermocouple: K, J, T, E, L, U, N, R, S, B, W, PLII
ES1B Infrared Thermosensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, 140 to 260°C.
Analog input: 4 to 20 mA, 0 to 20 mA, 1 to 5 V, 0 to 5 V, 0 to 10 V

Platinum resistance thermometer: Pt100, JPt100

Input impedance

Current input: 150Ω max., voltage input: 1 MΩ min.

Control outputs

Voltage output

Output voltage: 12 VDC ±15%, max. load current: 21 mA (PNP models with short-circuit protection circuit)

Transistor output

Max. operating voltage: 30 V, max. load current: 100 mA

-

Current output

Current output range: 4 to 20 mA or 0 to 20 mA DC
Load: 500 Ω max. (including transfer output)

(Resolution: Approx: 2,800 for 4 to 20 mA DC,
approx. 3,500 for 0 to 20 mA DC)

-

Event inputs

Input points

2

-

Contact input

ON: 1 kΩ max., OFF. 100 kΩ min.

-

Non-contact input

ON: Residual voltage: 1.5 V max.,
OFF: Leakage current: 0.1 mA max.

-

 

Outflow current: approx. 4 mA per point

-

Number of input and control points

Input points: 2, control points: 2

Input points: 4, control points: 4

Setting method

Via communications

Control method

ON/OFF control or 2-PID (with autotuning, selftuning, Heat & Cool autotuning and non-linear cool output selection)

Other functions

Two-point input shift, digital input filter, remote SP, SP ramp, manual manipulated variable, manipulated variable limiter, interference overshoot adjustment, loop burnout alarm, RUN/STOP, banks, I/O allocations, etc.

Alarm output

2 points via End unit

Communication

RS-485, PROFIBUS, Modbus, DeviceNet

RS-485, PROFIBUS, Modbus, DeviceNet

Size in mm (W×H×D)

31×96×109

Weight

180 g

Ambient temperature range

Operating -10°C to 55°C, Storage -25°C to 65°C (with no icing or condensation)

Ambient humidity range

Operating 25% to 85% (with no condensation)

Dimensions

Item

Size in mm (H×W×D)

EJ1N-HFU_-NFL_

95.4×31.0×104.9/109.0

EJ1N-HFUB-DRT

90.9×31.0×82.2

EJ1C-EDU

95.4×15.7×76.2/79.7


1.For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control.
On the 4-point models, heating/cooling control can be performed for two input points only.

2.When using the heater burnout alarm, purchase a Current Transformer (E54-CT1 or E54-CT3) separately.

3.This unit mounts to the left of the CelciuX° (EJ1) configuration and enables PROFINET or Modbus/TCP network connection. Combine the HFU-ETN with an EDU_-NFLK end unit to use with other devices supporting Modbus-RTU like E5_N temperature controllers and MX2 Inverters.

4.An End unit is always required for connection to a Basic unit or an HFU. An HFU cannot operate without a Basic unit.

5.Heating/cooling control is not supported for gradient temperature control.

6.When using the heater burnout alarm, use a Current Transformer (E54-CT1 or E54-CT3) (sold separately).

7.An End-unit (EDU) is always required to connect an HFU and or a Basic TC unit for Communications and Power supply.
A GTC (Gradient Temperature Control) basic TC unit always requires a GTC HFU unit.

8.Inputs are fully multi-input. Therefore, platinum resistance thermometer, thermocouple, infrared thermosensor, and analog input can be selected.

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.