E58-CIFQ1 176286 OMRON Temperature and Process, Cable Comm. USB-QLP E5 -AN / EN / CN / EJ1 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

E58-CIFQ1 176286 OMRON Temperature and Process, Cable Comm. USB-QLP E5 -AN / EN / CN / EJ1

E58-CIFQ1

176286

OMRON

Available

Ship on today

Temperature and Process, Cable Comm. USB-QLP E5 -AN / EN / CN / EJ1

More details


Temperature Sensors

Accessories Temperature and Processes

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

Quantity Price
1+$169.80
3+$157.83
5+$153.82
7+$151.59
10+$149.75
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



CelciuX° (EJ1) Advanced and Multi-Loop controllers
CelciuX° (EJ1) - Multi-Loop temperature control – Control and Connectivity
CelciuX° (EJ1) is designed to handle complex temperature profiles thanks to Omron’s unique Gradient temperature Control (GTC) algorithm and to offer easy program-less communication with Omron and third-party PLCs and HMI. Above all, CelciuX° (EJ1)
incorporates all “simple to use” clever temperature control technology, like 2-PID, dis- turbance control and various ways of tuning.
• Interfaces to a wide range of industrial networks
• Reduced engineering due to Program-less communications, Smart Active Parts and
Function Block Libraries
• Available with screw terminals and screw-less clamp terminals
• One unit handling various types of input, such as Pt, Thermocouple, mA, and V
input
• Gradient Temperature Control (GTC)
Ordering information
Type Control points Control outputs Auxiliary outputs Other functions Terminal Order code
Basic unit 2 2 voltage (pulse) 2 transistor (NPN) *1
2 CT input *2 + 2 event input M3 screws EJ1N-TC2A-QNHB
Basic unit 2 2 voltage (pulse) 2 transistor (NPN) *1 2 CT input *2 + 2 event input Screw-less clamp EJ1N-TC2B-QNHB Basic unit 2 2 current 2 transistor (NPN) *1 2 event input M3 screws EJ1N-TC2A-CNB Basic unit 2 2 current 2 transistor (NPN) *1 2 event input Screw-less clamp EJ1N-TC2B-CNB
Basic unit 4 4 voltage (pulse) – – M3 screws EJ1N-TC4A-QQ Basic unit 4 4 voltage (pulse) – – Screw-less clamp EJ1N-TC4B-QQ High function unit – – 4 transistor (NPN) 4 event input M3 screws EJ1N-HFUA-NFLK High function unit – – 4 transistor (NPN) 4 event input Screw-less clamp EJ1N-HFUB-NFLK
DeviceNet unit – – – – Screw connector EJ1N-HFUB-DRT
Ethernet unit*3
End unit *4
– – – – 3 x RJ45 EJ1N-HFU-ETN
– – 2 transistor (NPN) – M3 screws EJ1C-EDUA-NFLK
End unit *4 – – 2 transistor (NPN) – Removable Connector EJ1C-EDUC-NFLK
*1 For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control.
On the 4-point models, heating/cooling control can be performed for two input points only.
*2 When using the heater burnout alarm, purchase a Current Transformer (E54-CT1 or E54-CT3) separately.
*3 This unit mounts to the left of the CelciuX° (EJ1) configuration and enables PROFINET or Modbus/TCP network connection. Combine the HFU-ETN with an EDU_-NFLK end unit to use with other devices supporting Modbus-RTU like E5_N temperature controllers and MX2 Inverters.
*4 An End unit is always required for connection to a Basic unit or an HFU. An HFU cannot operate without a Basic unit.
Type Control points Control outputs Auxiliary outputs Other functions Terminal Order code
Basic unit 2 (GTC) 2 voltage (pulse)*1 2 transistor (NPN) 2 CT input*2
M3 screws EJ1G-TC2A-QNH
Basic unit 2 (GTC) 2 voltage (pulse)*1 2 transistor (NPN) 2 CT input*2 Screw-less clamp EJ1G-TC2B-QNH Basic unit 4 (GTC) 4 voltage (pulse)*1 – – M3 screws EJ1G-TC4A-QQ Basic unit 4 (GTC) 4 voltage (pulse)*1 – – Screw-less clamp EJ1G-TC4B-QQ
High function unit – (GTC) – 4 transistor (NPN) – M3 screws EJ1G-HFUA-NFLK
High function unit – (GTC) – 4 transistor (NPN) – Screw-less clamp EJ1G-HFUB-NFLK
End unit*3
– – 2 transistor (NPN) – M3 screws EJ1C-EDUA-NFLK
End unit*3 – – 2 transistor (NPN) – Removable Connector EJ1C-EDUC-NFLK
*1 Heating/cooling control is not supported for gradient temperature control.
*2 When using the heater burnout alarm, use a Current Transformer (E54-CT1 or E54-CT3) (sold separately).
*3 An End-unit (EDU) is always required to connect an HFU and or a Basic TC unit for Communications and Power supply.
A GTC (Gradient Temperature Control) basic TC unit always requires a GTC HFU unit.
Accessories
Current transformer
Diameter Order code
5.8 dia. E54-CT1
12.0 dia. E54-CT3
Communications and cables
Description Order code
G3ZA connecting cable 5 meter EJ1C-CBLA050
USB programming cable E58-CIFQ1
PC based configuration and tuning software CX-Thermo EST2-2C-MV4
PROFIBUS Gateway PRT1-SCU11
533
CelciuX° (EJ1) Advanced and Multi-Loop controllers
Specifications
Item Type EJ1_-TC2 EJ1_-TC4
Power supply voltage 24 VDC
Operating voltage range 85% to 110% of rated voltage
Power consumption 4 W max. (at maximum load) 5 W max. (at maximum load)
Input (see note)*1
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, PLII
ES1B Infrared Thermosensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, 140 to 260°C. Analog input: 4 to 20 mA, 0 to 20 mA, 1 to 5 V, 0 to 5 V, 0 to 10 V
Platinum resistance thermometer: Pt100, JPt100
Input impedance Current input: 150max., voltage input: 1 M min.
Control outputs Voltage output Output voltage: 12 VDC ±15%, max. load current: 21 mA (PNP models with short-circuit protection circuit)
Transistor output Max. operating voltage: 30 V, max. load current: 100 mA –
Current output Current output range: 4 to 20 mA or 0 to 20 mA DC – Load: 500  max. (including transfer output)
(Resolution: Approx: 2,800 for 4 to 20 mA DC, approx. 3,500 for 0 to 20 mA DC)
Event inputs Input points 2 –
Contact input ON: 1 k max., OFF. 100 k min. –
Non-contact input ON: Residual voltage: 1.5 V max., – OFF: Leakage current: 0.1 mA max.
Outflow current: approx. 4 mA per point –
Number of input and control points Input points: 2, control points: 2 Input points: 4, control points: 4
Setting method Via communications
Control method ON/OFF control or 2-PID (with autotuning, selftuning, Heat & Cool autotuning and non-linear cool output selection)
Other functions Two-point input shift, digital input filter, remote SP, SP ramp, manual manipulated variable, manipulated variable limiter, interference overshoot ad- justment, loop burnout alarm, RUN/STOP, banks, I/O allocations, etc.
Alarm output 2 points via End unit
Communication RS-485, PROFIBUS, Modbus, DeviceNet RS-485, PROFIBUS, Modbus, DeviceNet
Size in mm (W×H×D) 31×96×109
Weight 180 g
Ambient temperature range Operating –10°C to 55°C, Storage –25°C to 65°C (with no icing or condensation)
Ambient humidity range Operating 25% to 85% (with no condensation)
*1 Inputs are fully multi-input. Therefore, platinum resistance thermometer, thermocouple, infrared thermosensor, and analog input can be selected.
Dimensions
Item Size in mm (H×W×D) EJ1N-HFU_-NFL_ 95.4×31.0×104.9/109.0
EJ1N-HFUB-DRT 90.9×31.0×82.2
EJ1C-EDU 95.4×15.7×76.2/79.7
534

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.