E53-EN02 182902 OMRON Temperature and Process, RS-422 E5-AN / EN / AK / EK View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

E53-EN02 182902 OMRON Temperature and Process, RS-422 E5-AN / EN / AK / EK

E53-EN02

182902

OMRON

Available

Ship on today

Temperature and Process, RS-422 E5-AN / EN / AK / EK

More details


Temperature Sensors

Accessories Temperature and Processes

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

Quantity Price
1+$99.90
3+$93.95
5+$91.88
7+$90.72
10+$89.84
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Ordering information

Type

Input

Output

Fixed option

Alarms

Order code

48x48 mm model (includes supply voltage indication)

On-panel

Universal

TC/Pt/mV

mA/V

Relay output

3 software alarms

2 SUB outputs

E5CN-HR2M-500 AC100-240

E5CN-HR2MD-500 AC/DC24

Voltage (pulse)

E5CN-HQ2M-500 AC100-240

E5CN-HQ2MD-500 AC/DC24

Current output

E5CN-HC2M-500 AC100-240

E5CN-HC2MD-500 AC/DC24

Linear voltage output

E5CN-HV2M-500 AC100-240

E5CN-HV2MD-500 AC/DC24

Relay output

SV programmer (8 programs of 32 segments)

E5CN-HTR2M-500 AC100-240

E5CN-HTR2MD-500 AC/DC24

Voltage (pulse)

E5CN-HTQ2M-500 AC100-240

E5CN-HTQ2MD-500 AC/DC24

Current output

E5CN-HTC2M-500 AC100-240

E5CN-HTC2MD-500 AC/DC24

Linear voltage output

E5CN-HTV2M-500 AC100-240

E5CN-HTV2MD-500 AC/DC24

Note: - Output and Alarm Relays: 3 A/250 VAC, electrical life: 100,000 operations
- Output voltage (pulse): 12 V, 21 mA (ie. to drive solid state relays)
- Linear current: 0(4) to 20 mA
- Linear voltage output: 0 to 10 V

Accessories

E5CN-H option boards

(One slot available in each instrument)

Option

Order code

Event inputs

 

 

 

E53-CNBN2

Event inputs

Control output 2

Voltage (for driving SSR)

 

 

E53-CNQBN2

Event inputs

 

 

Heater burnout/SSR failure/Heater overcurrent detection

E53-CNHBN2

Event inputs

 

Transfer output

 

E53-CNBFN2

Communications RS-232C

Control output 2

Voltage (for driving SSR)

 

 

E53-CN01N2

Communications RS-232C

E53-CNQ01N2

Communications RS-232C

 

 

Heater burnout/SSR failure/Heater overcurrent detection

E53-CNH01N2

Communications RS-485

E53-CN03N2

Communications RS-485

Control output 2

Voltage (for driving SSR)

 

 

 

E53-CNQO3N2

Communications RS-485

 

 

Heater burnout/SSR failure/Heater overcurrent detection

E53-CNH03N2

Communications RS-485

 

 

3-phase heater burnout/SSR failure/Heater overcurrent detection

E53-CNHH03N2

 

Control output 2

Voltage (for driving SSR)

Transfer output

 

E53-CNQFN2

 

Control output 2

Voltage (for driving SSR)

 

Heater burnout/SSR failure/Heater overcurrent detection

E53-CNQHN2

 

Control output 2

Voltage (for driving SSR)

 

3-phase heater burnout/SSR failure/ Heater overcurrent detection

E53-CNQHHN2

 

Control method

Auxiliary output

Control output 1/2

Heater burnout

Transfer output

Order code (includes supply voltage indication)

96 × 96 mm model

48 × 96 mm model

Basic

2 alarm relays

none fitted, 2 slots

1-phase

 

E5AN-HAA2HBM-500 AC100-240

E5EN-HAA2HBM-500 AC100-240

none fitted, 2 slots

E5AN-HAA2HBMD-500 AC/DC24

E5EN-HAA2HBMD-500 AC/DC24

2 SSR output fitted

E5AN-HSS2HBM-500 AC100-240

E5EN-HSS2HBM-500 AC100-240

2 SSR output fitted

E5AN-HSS2HBMD-500 AC/DC24

E5EN-HSS2HBMD-500 AC/DC24

none fitted, 2 slots

3-phase

4 to 20 mA output

E5AN-HAA2HHBFM-500 AC100-240

E5EN-HAA2HHBFM-500 AC100-240

none fitted, 2 slots

E5AN-HAA2HHBFMD-500 AC/DC24

E5EN-HAA2HHBFMD-500 AC/DC24

2 SSR output fitted

E5AN-HSS2HHBFM-500 AC100-240

E5EN-HSS2HHBFM-500 AC100-240

2 SSR output fitted

E5AN-HSS2HHBFMD-500 AC/DC24

E5EN-HSS2HHBFMD-500 AC/DC24

3 alarm relays

none fitted, 2 slots

E5AN-HAA3BFM-500 AC100-240

E5EN-HAA3BFM-500 AC100-240

none fitted, 2 slots

E5AN-HAA3BFMD-500 AC/DC24

E5EN-HAA3BFMD-500 AC/DC24

2 SSR output fitted

E5AN-HSS3BFM-500 AC100-240

E5EN-HSS3BFM-500 AC100-240

2 SSR output fitted

E5AN-HSS3BFMD-500 AC/DC24

E5EN-HSS3BFMD-500 AC/DC24

Valve controller

2 alarm relays

2 relay output fitted

 

E5AN-HPRR2BM-500 AC100-240

E5EN-HPRR2BM-500 AC100-240

E5AN-HPRR2BMD-500 AC/DC24

E5EN-HPRR2BMD-500 AC/DC24

4 to 20 mA output

E5AN-HPRR2BFM-500 AC100-240

E5EN-HPRR2BFM-500 AC100-240

E5AN-HPRR2BFMD-500 AC/DC24

E5EN-HPRR2BFMD-500 AC/DC24

SV programmer (8 programs of 32 segments

2 alarm relays

none fitted, 2 slots

1-phase

 

E5AN-HTAA2HBM-500

E5EN-HTAA2HBM-500 AC100-240

E5AN-HTAA2HBMD-500

E5EN-HTAA2HBMD-500 AC/DC24

3-phase

4 to 20 mA output

E5AN-HTAA2HHBFM-500

E5EN-HTAA2HHBFM-500

E5AN-HTAA2HHBFMD-500

E5EN-HTAA2HHBFMD-500

3 alarm relays

E5AN-HTAA3BFM-500

E5EN-HTAA3BFM-500

E5AN-HTAA3BFMD-500

E5EN-HTAA3BFMD-500

SV programmer and valve controller

2 alarm relays

2 relay output fitted

 

E5AN-HTPRR2BM-500

E5EN-HTPRR2BM-500

E5AN-HTPRR2BMD-500

E5EN-HTPRR2BMD-500

4 to 20 mA output

E5AN-HTPRR2BFM-500

E5EN-HTPRR2BFM-500

E5AN-HTPRR2BFMD-500

E5EN-HTPRR2BFMD-500

Note: - All E5EN-H/AN-H have 2 event inputs
- All E5EN-H/AN-H have Remote Setpoint 4 to 20 mA input

 

Specifications E5CN-H/EN-H/AN-H

 

E5CN-H(T)

E5EN-H(T)

E5AN-H(T)

Supply voltage

100 to 240 VAC 50/60 Hz or 24 VAC, 50/60Hz; 24 VDC

Sensor input

Thermocouple: K, J, T, E, L, U, N, R, S, B, W or PL II

Platinum resistance thermometer: Pt100 or JPt100

Current input: 4 to 20 mA or 0 to 20 mA

Voltage input: 1 to 5 V, 0 to 5 V or 0 to 10 V

Control mode

ON/OFF, 2-PID and valve (PRR)

Accuracy

Thermocouple: (± 0.1% of indicated value or ±1°C, whichever is greater) ± digit max.
Platinum resistance thermometer: (± 0.1% of indicated value or ± 0.5°C, whichever is greater) ± 1 digit max.
Analog input: ± 0.1% FS ± 1 digit max.

Auto-tuning

yes, 40% and 100% MV output limit selection. When using Heat/Cool: automatic cool gain adjustment

Self-tuning

yes

RS-232C/RS-422/RS-485

optional, CompowayF or Modbus selectable

Event input

Optional (Standard 2 event input in EN-H/AN-H)

QLP port
(USB connection PC)

yes

Ambient temperature

−10 to 55°C

IP Rating front panel

IP66

Sampling period

60 ms

Sizes in mm (W × H × D)

48×48×76.5

48×96×77.2

96×96×77.2

E5AN-H/EN-H output option boards

(2 slots available in E5_N-HAA__-500 models: SS models have 2 fixed SSR output modules)

Option

Order code

Relay

E53-RN

Voltage (pulse) PNP 12 VDC

E53-QN

Voltage (pulse) NPN 24 VDC

E53-Q3

Voltage (pulse) PNP 24 VDC

E53-Q4

Linear 4 to 20 mA

E53-C3N

Linear 0 to 20 mA

E53-C3DN

Linear 0 to 10 V

E53-V34N

Linear 0 to 5 V

E53-V35N

E5AN-H/EN-H option boards

(one slot available in each instrument)

Option

Order code

RS-232C communications (CompoWay/F/Modbus)

E53-EN01

RS-422 communications (CompoWay/F/Modbus)

E53-EN02

RS-485 communications (CompoWay/F/Modbus)

E53-EN03

Event input

E53-AKB

E5AN-H/EN-H series optional tools

Option

Order code

USB PC based configuration cable

 

E58-CIFQ1

PC based configuration and tuning software

CX-Thermo

EST2-2C-MV4


1.With mounted terminal cover

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.