E53-EN01 182423 OMRON Temperature and Process, RS-232C E5-AN / EN / AK / EK View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

E53-EN01 182423 OMRON Temperature and Process, RS-232C E5-AN / EN / AK / EK

E53-EN01

182423

OMRON

Available

Ship on today

Temperature and Process, RS-232C E5-AN / EN / AK / EK

More details


Temperature Sensors

Accessories Temperature and Processes

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

Quantity Price
1+$102.51
5+$91.04
9+$88.38
13+$87.01
17+$86.18
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



E5_N-H/E5_N-HT Advanced and Multi-Loop controllers
Universal compact digital process controllers
The E5_N-H series of process controllers take the proven concept of the general pur- pose E5_N series to a process level. Main features of the E5_N-H series are universal
inputs, process outputs and options such as transfer output, remote setpoint and set- value programmer.
• Control mode: ON/OFF or 2-PID, Valve control on EN-H/AN-H
• Control output: relay, voltage (pulse), SSR, linear current and voltage
• Power supply: 100/240 VAC or 24 VDC/VAC
• Easy PC connection for parameter cloning, setting and tuning
• Clear and intuitive set-up and operation
Ordering information
Type Input Output Fixed option Alarms Order code
48x48 mm model (includes supply voltage indication)
On-panel Universal
Relay output – 3 software alarms
E5CN-HR2M-500 AC100-240 E5CN-HR2MD-500 AC/DC24
TC/Pt/mV
mA/V
Voltage (pulse)
2 SUB outputs
E5CN-HQ2M-500 AC100-240 E5CN-HQ2MD-500 AC/DC24
Current output E5CN-HC2M-500 AC100-240 E5CN-HC2MD-500 AC/DC24
Linear voltage output E5CN-HV2M-500 AC100-240 E5CN-HV2MD-500 AC/DC24
Relay output SV programmer
E5CN-HTR2M-500 AC100-240 E5CN-HTR2MD-500 AC/DC24
Voltage (pulse)
(8 programs of
32 segments)
E5CN-HTQ2M-500 AC100-240 E5CN-HTQ2MD-500 AC/DC24
Current output E5CN-HTC2M-500 AC100-240 E5CN-HTC2MD-500 AC/DC24
Linear voltage output E5CN-HTV2M-500 AC100-240 E5CN-HTV2MD-500 AC/DC24
Note: - Output and Alarm Relays: 3 A/250 VAC, electrical life: 100,000 operations
- Output voltage (pulse): 12 V, 21 mA (ie. to drive solid state relays)
- Linear current: 0(4) to 20 mA
- Linear voltage output: 0 to 10 V
Accessories
E5CN-H option boards
(One slot available in each instrument)
Option Order code
Event inputs E53-CNBN2
Event inputs Control output 2
Voltage (for driving SSR)
Event inputs Heater burnout/SSR failure/Heater overcurrent detection
E53-CNQBN2
E53-CNHBN2
Event inputs Transfer output E53-CNBFN2
Communications RS-232C Control output 2
E53-CN01N2
Communications RS-232C
Voltage (for driving SSR)
E53-CNQ01N2
Communications RS-232C Heater burnout/SSR failure/Heater
E53-CNH01N2
Communications RS-485
Communications RS-485 Control output 2
Voltage (for driving SSR)
overcurrent detection
E53-CN03N2
E53-CNQO3N2
Communications RS-485 Heater burnout/SSR failure/Heater overcurrent detection
Communications RS-485 3-phase heater burnout/SSR failure/ Heater overcurrent detection
E53-CNH03N2
E53-CNHH03N2
Control output 2
Voltage (for driving SSR)
Transfer output E53-CNQFN2
Control output 2
Voltage (for driving SSR)
Control output 2
Voltage (for driving SSR)
Heater burnout/SSR failure/Heater overcurrent detection
3-phase heater burnout/SSR failure/ Heater overcurrent detection
E53-CNQHN2
E53-CNQHHN2
529
E5_N-H/E5_N-HT Advanced and Multi-Loop controllers
Control method Auxiliary output Control output 1/2 Heater burnout Transfer output Order code (includes supply voltage indication)
96 × 96 mm model 48 × 96 mm model
Basic 2 alarm relays none fitted, 2 slots 1-phase E5AN-HAA2HBM-500 AC100-240 E5EN-HAA2HBM-500 AC100-240 none fitted, 2 slots E5AN-HAA2HBMD-500 AC/DC24 E5EN-HAA2HBMD-500 AC/DC24
2 SSR output fitted E5AN-HSS2HBM-500 AC100-240 E5EN-HSS2HBM-500 AC100-240
2 SSR output fitted E5AN-HSS2HBMD-500 AC/DC24 E5EN-HSS2HBMD-500 AC/DC24 none fitted, 2 slots 3-phase 4 to 20 mA output E5AN-HAA2HHBFM-500 AC100-240 E5EN-HAA2HHBFM-500 AC100-240 none fitted, 2 slots E5AN-HAA2HHBFMD-500 AC/DC24 E5EN-HAA2HHBFMD-500 AC/DC24
2 SSR output fitted E5AN-HSS2HHBFM-500 AC100-240 E5EN-HSS2HHBFM-500 AC100-240
2 SSR output fitted E5AN-HSS2HHBFMD-500 AC/DC24 E5EN-HSS2HHBFMD-500 AC/DC24
3 alarm relays none fitted, 2 slots E5AN-HAA3BFM-500 AC100-240 E5EN-HAA3BFM-500 AC100-240 none fitted, 2 slots E5AN-HAA3BFMD-500 AC/DC24 E5EN-HAA3BFMD-500 AC/DC24
2 SSR output fitted E5AN-HSS3BFM-500 AC100-240 E5EN-HSS3BFM-500 AC100-240
2 SSR output fitted E5AN-HSS3BFMD-500 AC/DC24 E5EN-HSS3BFMD-500 AC/DC24
Valve controller 2 alarm relays 2 relay output fitted E5AN-HPRR2BM-500 AC100-240 E5EN-HPRR2BM-500 AC100-240
E5AN-HPRR2BMD-500 AC/DC24 E5EN-HPRR2BMD-500 AC/DC24
4 to 20 mA output E5AN-HPRR2BFM-500 AC100-240 E5EN-HPRR2BFM-500 AC100-240
E5AN-HPRR2BFMD-500 AC/DC24 E5EN-HPRR2BFMD-500 AC/DC24
SV programmer
(8 programs of
32 segments
2 alarm relays none fitted, 2 slots 1-phase E5AN-HTAA2HBM-500 E5EN-HTAA2HBM-500 AC100-240
E5AN-HTAA2HBMD-500 E5EN-HTAA2HBMD-500 AC/DC24
3-phase 4 to 20 mA output E5AN-HTAA2HHBFM-500 E5EN-HTAA2HHBFM-500
E5AN-HTAA2HHBFMD-500 E5EN-HTAA2HHBFMD-500
3 alarm relays E5AN-HTAA3BFM-500 E5EN-HTAA3BFM-500
E5AN-HTAA3BFMD-500 E5EN-HTAA3BFMD-500
SV programmer and 2 alarm relays 2 relay output fitted E5AN-HTPRR2BM-500 E5EN-HTPRR2BM-500
valve controller
Note: - All E5EN-H/AN-H have 2 event inputs
- All E5EN-H/AN-H have Remote Setpoint 4 to 20 mA input
E5AN-HTPRR2BMD-500 E5EN-HTPRR2BMD-500
4 to 20 mA output E5AN-HTPRR2BFM-500 E5EN-HTPRR2BFM-500
E5AN-HTPRR2BFMD-500 E5EN-HTPRR2BFMD-500
Specifications E5CN-H/EN-H/AN-H E5AN-H/EN-H output option boards
E5CN-H(T) E5EN-H(T) E5AN-H(T) Supply voltage 100 to 240 VAC 50/60 Hz or 24 VAC, 50/60Hz 24 VDC Sensor input Thermocouple: K, J, T, E, L, U, N, R, S, B, W or PL II
Platinum resistance thermometer: Pt100 or JPt100
Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V or 0 to 10 V
Control mode ON/OFF, 2-PID and valve (PRR)
Accuracy Thermocouple: (± 0.1% of indicated value or ±1°C, whichever is greater) ± digit max.
Platinum resistance thermometer: (± 0.1% of indicated value or
± 0.5°C, whichever is greater) ± 1 digit max. Analog input: ± 0.1% FS ± 1 digit max.
Auto-tuning yes, 40% and 100% MV output limit selection. When using
Heat/Cool: automatic cool gain adjustment
Self-tuning yes
RS-232C/RS-422/RS-485 optional, CompowayF or Modbus selectable
Event input Optional (Standard 2 event input in EN-H/AN-H)
(2 slots available in E5_N-HAA__-500 models: SS models have 2 fixed SSR output modules)
Option Order code Relay E53-RN Voltage (pulse) PNP 12 VDC E53-QN Voltage (pulse) NPN 24 VDC E53-Q3
Voltage (pulse) PNP 24 VDC E53-Q4
Linear 4 to 20 mA E53-C3N Linear 0 to 20 mA E53-C3DN Linear 0 to 10 V E53-V34N Linear 0 to 5 V E53-V35N
E5AN-H/EN-H option boards
(one slot available in each instrument)
Option Order code
RS-232C communications (CompoWay/F/Modbus) E53-EN01
RS-422 communications (CompoWay/F/Modbus) E53-EN02
QLP port
(USB connection PC)
yes
RS-485 communications (CompoWay/F/Modbus) E53-EN03
Event input E53-AKB
Ambient temperature –10 to 55°C
IP Rating front panel IP66
Sampling period 60 ms
Sizes*1 in mm (W × H × D) 48×48×76.5 48×96×77.2 96×96×77.2
*1 With mounted terminal cover
E5AN-H/EN-H series optional tools
Option Order code
USB PC based configuration cable E58-CIFQ1
PC based configuration and tuning software CX-Thermo EST2-2C-MV4
530

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.