Product successfully added to your shopping cart
01-3876-12
366952
01387612PROFINETSX2PORT
OMRON
1
SX-series PROFINET IO option board 2 ports
Frequency inverters > Accessories Frequency inverters
Brand new product in its original packaging covered by the warranties and certifications provided by OMRON
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Designed to drive any high power application from 90 kW up to 1 MW, the new SX series of compact inverters features embedded application dedicated functionality plus logic programming and customizable LCD information to give you all the control flexibility required for applications ranging from high torque to smooth flow and pressure control.
Specifications | Order code | |||||||
|---|---|---|---|---|---|---|---|---|
Voltage | Heavy duty | Normal duty | IP54 model | IP20 model | ||||
Direct torque control | V/F | Direct torque control | V/F | |||||
690 V | 75 kW | 72 A | 90 kW | 90 A | SX-D6090-EF | SX-D6090-EV | - | - |
90 kW | 87 A | 110 kW | 109 A | SX-D6110-EF | SX-D6110-EV | |||
110 kW | 117 A | 132 kW | 146 A | SX-D6132-EF | SX-D6132-EV | |||
132 kW | 140 A | 160 kW | 175 A | SX-D6160-EF | SX-D6160-EV | |||
160 kW | 160 A | 200 kW | 200 A | SX-D6200-E1F | SX-D6200-E1V | |||
200 kW | 200 A | 250 kW | 250 A | SX-D6250-E1F | SX-D6250-E1V | SX-A6250-EF | SX-A6250-EV | |
250 kW | 240 A | 315 kW | 300 A | SX-D6315-E1F | SX-D6315-E1V | SX-A6315-EF | SX-A6315-EV | |
315 kW | 300 A | 355 kW | 375 A | SX-D6355-E1F | SX-D6355-E1V | SX-A6355-EF | SX-A6355-EV | |
315 kW | 344 A | 450 kW | 430 A | SX-D6450-E1F | SX-D6450-E1V | SX-A6450-EF | SX-A6450-EV | |
355 kW | 400 A | 500 kW | 500 A | SX-D6500-E1F | SX-D6500-E1V | SX-A6500-EF | SX-A6500-EV | |
450 kW | 480 A | 600 kW | 600 A | SX-D6600-E1F | SX-D6600-E1V | SX-A6600-EF | SX-A6600-EV | |
500 kW | 520 A | 630 kW | 650 A | SX-D6630-E1F | SX-D6630-E1V | SX-A6630-EF | SX-A6630-EV | |
600 kW | 576 A | 710 kW | 720 A | SX-D6710-E1F | SX-D6710-E1V | SX-A6710-EF | SX-A6710-EV | |
650 kW | 640 A | 800 kW | 800 A | SX-D6800-E1F | SX-D6800-E1V | SX-A6800-EF | SX-A6800-EV | |
710 kW | 720 A | 900 kW | 900 A | SX-D6900-E1F | SX-D6900-E1V | SX-A6900-EF | SX-A6900-EV | |
800 kW | 800 A | 1,000 kW | 1,000 A | SX-D61K0-E1F | SX-D61K0-E1V | SX-A61K0-EF | SX-A61K0-EV | |
Type | Description | Function | Order code |
|---|---|---|---|
Panel kit | Panel kit | Complete panel kit including operator | SX-OP02-00-E |
Blank panel kit | Complete panel kit including a blank operator | SX-OP02-01-E | |
Operator | Handheld control panel | Complete handheld control panel | SX-OPHH-00-E |
Digital operator | Inverter digital operator | SX-OP01-00-E | |
Blank operator | Blank operator | SX-OP01-11-E |
Description | Function | Order code |
|---|---|---|
Additional I/O option | Provides 3 extra relay outputs and 3 additional digital inputs | 01-3876-01 |
Crane option | Dedicated option board for crane application, including additional I/O and functions | 01-3876-07 |
Description | Function | Order code |
|---|---|---|
RS232/485 | MODBUS RTU serial communication by RS232 or RS485 interface with galvanic isolation | 01-3876-04 |
PROFIBUS-DP | Used for operating the inverter through PROFIBUS-DP communication with the host controller | 01-3876-05 |
DeviceNet | Used for operating the inverter through DeviceNet communication with the host controller | 01-3876-06 |
Modbus/TCP, Ethernet | Used for operating the inverter through Modbus/TCP communication with the host controller | 01-3876-09 |
EtherCAT | Used for operating the inverter through EtherCAT communication with the host controller | 01-3876-10 |
PROFINET (1-port) | Used for operating the inverter through PROFINET communication with the host controller | 01-3876-11 |
PROFINET (2-ports) | 01-3876-12 |
Description | Function | Order code |
|---|---|---|
Encoder option | Used for connection of the actual motor speed via encoder. Up to 100 kHz with TTL and HTL incremental encoders with 5/24 V power supply | 01-3876-03 |
Description | Function | Order code |
|---|---|---|
Thermal protection | Allows to connect a motor thermistor to the inverter | 01-3876-08 |
All inverter sizes could be fitted with an optional built-in brake chopper from factory but is not possible to install it later. The choice of the resistor depends on the application switch-on duration and duty-cycle. Following tables describes the activation level of the built-in braking chopper and the minimum resistor that could be used depending on the input voltage.
Rmin for different input voltage (Ω) | Order code | ||
|---|---|---|---|
500-525 VAC | 550-600 VAC | 660-690 VAC | |
4.9 | 5.7 | 6.5 | SX-D6090-EF |
4.9 | 5.7 | 6.5 | SX-D6110-EF |
4.9 | 5.7 | 6.5 | SX-D6132-EF |
4.9 | 5.7 | 6.5 | SX-D6160-EF |
2 × 4.9 | 2 × 5.7 | 2 × 6.5 | SX-D6200-EF |
2 × 4.9 | 2 × 5.7 | 2 × 6.5 | SX-D6250-EF |
2 × 4.9 | 2 × 5.7 | 2 × 6.5 | SX-D6315-EF |
2 × 4.9 | 2 × 5.7 | 2 × 6.5 | SX-D6355-EF |
3 × 4.9 | 3 × 5.7 | 3 × 5.7 | SX-D6450-EF |
3 × 4.9 | 3 × 5.7 | 3 × 5.7 | SX-D6500-EF |
4 × 4.9 | 4 × 5.7 | 4 × 5.7 | SX-D6600-EF |
4 × 4.9 | 4 × 5.7 | 4 × 5.7 | SX-D6630-EF |
6 × 4.9 | 6 × 5.7 | 6 × 5.7 | SX-D6710-EF |
6 × 4.9 | 6 × 5.7 | 6 × 5.7 | SX-D6800-EF |
6 × 4.9 | 6 × 5.7 | 6 × 5.7 | SX-D6900-EF |
6 × 4.9 | 6 × 5.7 | 6 × 5.7 | SX-D61K0-EF |
Supply voltage (VAC) | Built-in brake chopper trigger level (VDC) |
|---|---|
500-525 | 860 |
550-600 | 1,000 |
660-690 | 1,150 |
Output coils above SX-D4132-E should be order from factory as they should be installed inside of the cabinet
Voltage | Inverter model | Rated current | Inductance | Rated voltage | Max carrier | Max. output frequency | Max. temp | Order code |
|---|---|---|---|---|---|---|---|---|
690 V | SX-D6090-EF | 90 A | 0.1 mH | 800 V | 6 kHz | 200 Hz | 40ºC | 473169 00 |
SX-D6110-EF | 146 A | 0.05 mH | 6 kHz | 200 Hz | 473170 00 | |||
SX-D6132-EF | ||||||||
SX-D6160-EF | 175 A | 0.05 mH | 6 kHz | 200 Hz | 473171 00 |
Note:Only two types of overshoot clamps could be order for after mounting
Inverter | Function | Order code |
|---|---|---|
SX-6090 to SX-6160 | Together with the output coils, the overshoot clamp restricts the voltage and the dV/dt on the motor winding. | 52163 |
SX-6200 to SX-61K0 | Together with the output coils, the overshoot clamp restricts the voltage and the dV/dt on the motor winding. | 52220 |
Installation | Order code |
|---|---|
Configuration and monitoring software tool | CX-Drive |
Configuration and monitoring software tool | CX-One |
Software tool for energy saving calculation | €Saver |
Three-phase: SX-_6__-E_ | 90 | 110 | 132 | 160 | 200 | 250 | 315 | 355 | 450 | 500 | 600 | 630 | 710 | 800 | 900 | 1K0 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Motor | For HD setting | 75 | 90 | 110 | 132 | 160 | 200 | 250 | 315 | 315 | 355 | 450 | 500 | 600 | 650 | 710 | 800 |
For ND setting | 90 | 110 | 132 | 160 | 200 | 250 | 315 | 355 | 450 | 500 | 600 | 630 | 710 | 800 | 900 | 1,000 | |
Output | Max output current (A) | 108 | 131 | 175 | 210 | 252 | 300 | 360 | 450 | 516 | 600 | 720 | 780 | 900 | 1,032 | 1,080 | 1,200 |
Rated output current (A) at HD | 72 | 87 | 117 | 140 | 160 | 200 | 240 | 300 | 344 | 400 | 480 | 520 | 576 | 640 | 720 | 800 | |
Rated output current (A) at ND | 90 | 109 | 146 | 175 | 200 | 250 | 300 | 375 | 430 | 500 | 600 | 650 | 720 | 800 | 900 | 1,000 | |
Output voltage | 0 to Mains supply voltage | ||||||||||||||||
Max. output frequency | 400 Hz | ||||||||||||||||
Power | Rated input voltage and frequency | 3-phase 500 to 690 V, 50/60 Hz | |||||||||||||||
Allowable voltage fluctuation | 10% to -15% | ||||||||||||||||
Allowable frequency fluctuation | 45 to 65 Hz | ||||||||||||||||
Degree of protection | Drive model | H | W | D | |
|---|---|---|---|---|---|
IP20 | SX-A6250 to SX-A6355 | 1,176 | 500 | 450 | |
SX-A6450 to SX-A6600 | 1,176 | 730 | 450 | ||
SX-A6630 to SX-A6800 | 1,176 | 1,100 | 450 | ||
SX-A6900 to SX-A61K0 | 1,176 | 1,365 | 450 | ||
IP54 | SX-D6090 to SX-D6200 | 952.5 | 344.5 | 314 | |
SX-D6250 to SX-D6355 | 2,250 | 600 | 600 | ||
SX-D6450 to SX-D6600 | 2,250 | 900 | 600 | ||
SX-D6630 to SX-D6800 | 2,250 | 1,200 | 600 | ||
SX-D6900 to SX-D61K0 | 2,250 | 1,500 | 600 |
1.Based on a standard 4-pole motor for maximum applicable motor output
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGO OMRON AUTOMATION EN.pdf | 19 Mbytes |
|
| PDF CATALOG OMRON 2024 EN.pdf | 25 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.