VG-BC DC-TS900 5088635 OBO BETTERMANN DEVICE PROTECTION VG-BC DC-TS900

VG-BC DC-TS900

5088635

OBO BETTERMANN

DEVICE PROTECTION VG-BC DC-TS900

Generator connection box, type 1+2, to 900 V DC with disconnection switch (32 A) 1 x 1 string. System solution for circuit breaker photovoltaic inverter with 1 MPP tracker• Varistor arrester, connectable with cut-off unit in error-resistant Y circuit to VDE 0100-712 (50539-12) • Low DC protection level: < 3.0 kV (Voc max = 900 V DC with V25-B+C/0-450PV) • Circuit breaker (1,000 V; 32 A) for secure switch-off of the DC string cable• Per protection device there is 1 terminal up to 6 mm² pre-mounted in the housing, up to 30 A DC per terminal • Pre-mounted in polycarbonate housing (IP65), UV-resistant for use outside, including cable gland kitFor DC protection of the inverter in photovoltaic systems.If there is a danger of condensation forming through wind, ice, temperature or sunlight, furt

More details


TBS Transient and lightning protection systems - OBO BETTERMANN

Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Anschlussart GeneratoranschlusskastenTension spring terminal
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate3,4202 kg CO2e / 1 Piece
ColourLight grey; RAL 7035
Conductor cross-section, rigid (single-wire/multiwire), max.6 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.0,5 mm²
DC network formyes
Depth122 mm
Dimension900V DC
Entries per MPPT1
Equipped with load-break switchyes
Exits per MPPT1
Installation typePre-mounted in the housing
IT network formno
Lightning protection zone LPZ0→2
Lightning surge current (10/350 μs)7 kA
Max. Input current per string30 A
Max. Input voltage DC900 V
Max. mains-side overcurrent protection160
Max. Output current30 A
Maximum back-up fuse160 A
Maximum continuous voltage DC900 V
Maximum discharge current (8/20 μs)50 kA
Monitoring functionno
Network formDC
Nominal discharge current (8/20 µs)30 kA
Number of cable entries16
Number of inputs1
Number of MPPTs1
Number of string inputs1
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Other network formno
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Protection ratingIP65
Remote signallingno
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 1+2
SPD to IEC 61643-1Class I+II
String fuseWithout
TN network formno
TN-C network formno
TN-C-S network formno
TN-S network formno
TT network formno
Type of entryGland
Version forType 1+2 and Benedikt LS32-SMA-A4 DC isolator

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE SURGE PROTECTION OBO EN.pdf 24 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.