ANUNCIAR
VF48-AC/DC-FS 5097822 OBO BETTERMANN Lightning barrier with remote signalling, 48V AC, View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VF48-AC/DC-FS 5097822 OBO BETTERMANN Lightning barrier with remote signalling, 48V AC,

VF48-AC/DC-FS

5097822

OBO BETTERMANN

Lightning barrier with remote signalling, 48V AC,

MCR protection for 2-pole power supply with remote signalling, 48 V AC/DC. Surge protection/fine power protection, type 3, to EN 61643-11 with remote signalling • With remote signalling, potential-free changeover contact, for function monitoring • Suitable for DC and AC systems • With visual function display • With easy mounting, screwless connection terminals • In space-saving 17.5 mm grid • Y circuit Application: Universal use on 35 mm DIN profile rails in any standard distributor housing.

More details


Earthing, lightning and surge protection > Surge protection device for terminal equipment

TBS Transient and lightning protection systems - OBO BETTERMANN > Surge protection, arrestor, type 3 - OBO BETTERMANN

Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN

Total: $97.55
Unit price: $97.55
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate0,6888 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.2,5 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.0,14 mm²
Dimension48V AC
FM contactsChangeover
Installation typeDIN rail 35 mm
Lightning protection zone LPZ2→3
Maximum continuous voltage AC60 V
Maximum continuous voltage DC80 V
Maximum discharge current (8/20 μs)2 kA
Network formOther
Nominal discharge current (8/20 µs)0,7 kA
Nominal voltage AC (50/60 Hz)48 V
OBO_Nominal load current (input/output terminal)20 A
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole number3
Pole version2
Protection level wire-earth<1200 V
Protection level wire-wire<220 V
Protection ratingIP20
Remote signallingyes
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 3
SPD to IEC 61643-1Class III
Test class, type 3yes

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.