Lightning barrier with remote signalling, 48V AC,
MCR protection for 2-pole power supply with remote signalling, 48 V AC/DC. Surge protection/fine power protection, type 3, to EN 61643-11 with remote signalling • With remote signalling, potential-free changeover contact, for function monitoring • Suitable for DC and AC systems • With visual function display • With easy mounting, screwless connection terminals • In space-saving 17.5 mm grid • Y circuit Application: Universal use on 35 mm DIN profile rails in any standard distributor housing.
Earthing, lightning and surge protection > Surge protection device for terminal equipment
TBS Transient and lightning protection systems - OBO BETTERMANN > Surge protection, arrestor, type 3 - OBO BETTERMANN
Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Blow-out | no |
|---|---|
| CO2 Footprint (GWP) Cradle-to-Gate | 0,6888 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 2,5 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 0,14 mm² |
| Dimension | 48V AC |
| FM contacts | Changeover |
| Installation type | DIN rail 35 mm |
| Lightning protection zone LPZ | 2→3 |
| Maximum continuous voltage AC | 60 V |
| Maximum continuous voltage DC | 80 V |
| Maximum discharge current (8/20 μs) | 2 kA |
| Network form | Other |
| Nominal discharge current (8/20 µs) | 0,7 kA |
| Nominal voltage AC (50/60 Hz) | 48 V |
| OBO_Nominal load current (input/output terminal) | 20 A |
| Operating temperature, max. | 80 °C |
|---|---|
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole number | 3 |
| Pole version | 2 |
| Protection level wire-earth | <1200 V |
| Protection level wire-wire | <220 V |
| Protection rating | IP20 |
| Remote signalling | yes |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 3 |
| SPD to IEC 61643-1 | Class III |
| Test class, type 3 | yes |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SURGE PROTECTION OBO EN.pdf | 24 Mbytes |
|
| VF48-AC/DC-FS 5097822 OBO BETTERMANN Lightning barrier with remote signalling, 48V AC, | 47 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.