Product successfully added to your shopping cart
TV 4+1
5083400
OBO BETTERMANN
1
Surge protection device for antenna systems,
Coaxial protection device for SAT and cable multi-switch. Coaxial data line protection for TV reception systems• Protects up to four SAT lines• Protects one terrestrial line, e.g. DVB-T.• Simple mounting using screws and holder• With F-connector• Optimum transmission behaviour with 75 Ohm technology.Application: Protection of TV and SAT systems, multi-switches, receivers and DVB-T receivers
Earthing, lightning and surge protection > Combined arrester for data networks/MCR-technology
TBS Transient and lightning protection systems - OBO BETTERMANN > Surge protection, arrestor, type 3 - OBO BETTERMANN
Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Arrestor monitoring | no |
|---|---|
| Capacity (wire-earth) | <500 pF |
| Capacity (wire-wire) | <500 pF |
| CO2 Footprint (GWP) Cradle-to-Gate | 1,1222 kg CO2e / 1 Piece |
| Cut-off frequency | 2800 MHz |
| Dimension | 70V |
| Earthing via: | Connection cable |
| Explosion-tested version | no |
| Impulse durability wire-earth | C2: 10 kV / 5 kA (8/20µs) |
| Impulse durability wire-wire | C2: 10 kV / 5 kA (8/20µs) |
| Insertion loss | ≤3 dB |
| Insulation resistance | >1 GΩ |
| Kategorie | Type 2+3 / C2+C1 |
| Lightning impulse current | 2,5 kA |
| Lightning impulse current terrestrial input | 1 |
| Lightning protection zone LPZ | 1→3 |
| Maximum continuous voltage AC | 130 V |
| Maximum continuous voltage DC | 185 V |
| Maximum continuous voltage Vc SAT inputs | 22 V |
| Maximum continuous voltage Vc terrestrial input | 70 V |
| Nominal discharge current SAT inputs | 300 A |
| Nominal load current AC | 1,4 A |
| Nominal load current DC | 2 A |
| Number of poles | 5 |
|---|---|
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Plug-in system | F |
| Protection level | <800 V |
| Protection level wire-earth | <800 V |
| Protection level wire-wire | <800 V |
| Protection level SAT inputs at In | <45 V |
| Protection level Terrestrial input at In | <500 V |
| Protection rating | IP10 |
| Response time | <1 ns |
| Return loss | >30 dB |
| Screening | Direct |
| Shielding connection available | yes |
| Signalling on device | None |
| SPD to IEC 61643-21 | Class II+III / C2+C1 |
| Telecommunications contact | no |
| Testing standard | IEC 61643-21 |
| Total discharge current (10/350) | 5 kA |
| Total discharge current (8/20) | 0,5 kA |
| Version for | Fine protection device |
| Wave resistance | 75 Ω |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SURGE PROTECTION OBO EN.pdf | 24 Mbytes |
|
| TV 4+1 5083400 OBO BETTERMANN Surge protection device for antenna systems, | 56 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.