Product successfully added to your shopping cart
FLD 2-24
5098816
OBO BETTERMANN
1
Lightning barrier with decoupling inductivity, 24V AC,
Medium and fine protection for two-core systems 24 V. Surge protection for use in measurement and control technology • Medium and fine protection • Standard design for single core systems • Two-stage protection circuit • With installation-friendly, screwless connection terminals • In space-saving 17.5 mm grid • With inductive decoupling in the longitudinal branchApplication: Universal use on any 35 mm DIN profile rail in every commercially available distributor housing.
Earthing, lightning and surge protection > Combined arrester for data networks/MCR-technology
TBS Transient and lightning protection systems - OBO BETTERMANN > Surge protection, arrestor, type 3 - OBO BETTERMANN
Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Approvals | UL |
|---|---|
| Capacity (wire-earth) | <10 nF |
| Capacity (wire-wire) | <10 nF |
| CO2 Footprint (GWP) Cradle-to-Gate | 0,295 kg CO2e / 1 Piece |
| Connection cross-section, flexible, max. | 2,5 mm² |
| Connection cross-section, flexible, min. | 0,14 mm² |
| Connection cross-section, multi-wire, max. | 2,5 mm² |
| Connection cross-section, multi-wire, min. | 0,14 mm² |
| Connection cross-section, rigid, max. | 2,5 mm² |
| Connection cross-section, rigid, min. | 0,14 mm² |
| Dimension | 24V AC |
| Division unit TE (17.5 mm) | 1 |
| Earthing via: | Terminal |
| Explosion-tested version | no |
| Impulse durability wire-earth | C1: 1 kV / 0,5 kA (8/20µs) |
| Impulse durability wire-wire | C1: 1 kV / 0,5 kA (8/20µs) |
| Insertion loss | 3dB @ 150 kHz dB |
| Insulation resistance | > 10 MΩ |
| Kategorie | Type 2+3 / C2+C1 |
| Lightning protection zone LPZ | 1→3 |
|---|---|
| Maximum continuous voltage AC | 19 V |
| Maximum continuous voltage DC | 28 V |
| Nominal discharge current (8/20 µs) | 0,5 kA |
| Nominal load current AC | 0,7 A |
| Nominal load current DC | 1 A |
| Number of poles | 2 |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Plug-in system | Terminal |
| Protection level wire-earth | <60 V |
| Protection level wire-wire | <120 V |
| Protection rating | IP20 |
| Series inductivity per wire | 120 µH ± 10 % |
| Shielding connection available | no |
| SPD to IEC 61643-21 | Class II+III / C2+C1 |
| Telecommunications contact | no |
| Testing standard | IEC 61643-21 |
| Total discharge current (8/20) | 1 kA |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SURGE PROTECTION OBO EN.pdf | 24 Mbytes |
|
| FLD 2-24 5098816 OBO BETTERMANN Lightning barrier with decoupling inductivity, 24V AC, | 46 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.