OBO BETTERMANN V20-C 2+FS-280 5094632 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

V20-C 2+FS-280 5094632 OBO BETTERMANN SurgeController V20 2-pole with remote signalling, 280V,

Reference: V20-C 2+FS-280

Code: 5094632

Manufacturer: OBO BETTERMANN

Description:

SurgeController V20 2-pole with remote signalling, 280V,
Surge arrester, 2-pole with remote signalling 280 V. Surge arrester, type 2• Complete unit consisting of cover and base, pre-mounted and ready for connection• Suitable for TN network systems• Plug-in upper part; upper part can be separated from base without tools• With remote signalling and potential-free NO contact for function monitoring• Incl. thermal and dynamic cut-off unit• With visual display of defects• High current conductivity and long service life• Labelled connectionsApplication example: Residential buildings, single-family homes and industrial* Complete = cover and base

Categories:

  • Earthing, lightning and surge protection > Surge protection device for power supply systems
  • OBO BETTERMANN > TBS Transient and lightning protection systems - OBO BETTERMANN > Surge protection, arrestor, type 2 - OBO BETTERMANN

Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN

  • More Info
  • PDF
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

LAST VIEWED

MORE INFO

Arrester surge current (8/20 µs) [total]40 kA
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate0,8753 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
Dimension280V
Installation typeDIN rail 35 mm
Integrated back-up fuseno
Lightning protection zone LPZ1→2
Max. mains-side overcurrent protection125
Maximum back-up fuse125 A
Maximum continuous voltage AC280 V
Maximum discharge current (8/20 μs)40 kA
Network formTN
Nominal discharge current (8/20 µs)20 kA
Nominal discharge current (8/20 µs) [L-N]20 kA
Nominal voltage AC (50/60 Hz)230 V
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole version2
Protection ratingIP20
Remote signallingyes
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 2
SPD to IEC 61643-1Class II
Test class, type 2yes
Version for2-pole + FS

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.