ANUNCIAR
MCD 50-B 3+1-OS 5096836 OBO BETTERMANN Coordinated lightning cont. set with function display, 255V, View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MCD 50-B 3+1-OS 5096836 OBO BETTERMANN Coordinated lightning cont. set with function display, 255V,

MCD 50-B 3+1-OS

5096836

OBO BETTERMANN

Coordinated lightning cont. set with function display, 255V,

Combination arrester, 3-pole + NPE with function display. Combination arrester, type 1+2, 4-pole, with visual function display, for use in TN-S and TT networks.Completely pre-terminated and ready for connection, consisting of:3x MCD 50-B-OS: Type 1+2 (Class B) coordinated lightning current arrester EN 61643-11.1x MCD 125-B/NPE: Coordinated N-PE spark gap, type 1+2 EN 61643-11 for use in TN-S and TT systems. Interface 0 to 2 (LPZ) according to lightning protection zone concept according to IEC 62305 and VDE 0185-305.• Lightning protection equipotential bonding to VDE 0185-305 (IEC 62305)• Lightning current arresting capacity to 50 kA (10/350) per pole and up to 125 kA (10/350) in total• Protection level < 1.7 kV allows device protection• Short-circuit resistance 10 kA, arrester backup fus

More details


Earthing, lightning and surge protection > Lightning current arrester for power supply systems

TBS Transient and lightning protection systems - OBO BETTERMANN > Surge protection, arrestor, type 1 (industry) - OBO BETTERMANN

Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN

Total: $984.24
Unit price: $984.24
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



ApprovalsVDE
Arrester surge current (8/20 µs) [total]125 kA
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate8,7853 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.50 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.10 mm²
DC network formno
Dimension255V
Follow current quenching capacity (eff) [N-PE]0,1 kA
Height69 mm
Installation typeDIN rail 35 mm
IT network formno
Length100 mm
Lightning protection zone LPZ0→2
Lightning surge current (10/350 μs)50 kA
Lightning surge current (10/350)125 kA
Max. mains-side overcurrent protection500
Maximum back-up fuse500 A
Maximum continuous voltage (L-N)255 V
Maximum continuous voltage (N-PE)255 V
Maximum continuous voltage AC255 V
Network formTN-S, TT
Nominal discharge current (8/20 µs)50 kA
Nominal discharge current (8/20 µs) [L-N]50 kA
Nominal discharge current (8/20 µs) [N-PE]125 kA
Nominal voltage AC (50/60 Hz)230 V
OBO_Nominal load current (input/output terminal)125 A
Operating temperature, max.85 °C
Operating temperature, min.-40 °C
Other network formno
Permitted temperature range, max.85 °C
Permitted temperature range, min.-40 °C
Pole number1
Pole version3+N/PE
Protection level [L-N]≤1,7
Protection ratingIP20
Remote signallingno
Response time<100 ns
Short-circuit resistance10 kA
Short-circuit resistance for max. mains-side overcurrent protection10 kA
Signalling on deviceVisual
SPD to EN 61643-11Type 1+2
SPD to IEC 61643-1Class I+II
Test class, type 1yes
Test class, type 2yes
TN network formyes
TN-C network formno
TN-C-S network formyes
TN-S network formyes
TT network formyes
Version for3+1-pole
Width140 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.