Product successfully added to your shopping cart
MC 50-B VDE
5096847
OBO BETTERMANN
1
LightningController , UC 255 V,
Lightning arrester, 1-pole. Type 1 lightning arrester in accordance with DIN EN 61643-11 for interface 0 to 1 (LPZ) to and/or in accordance with lightning protection concept to IEC 61312-1 and/or VDE 0185-305 (IEC 62305) • Cover and base, plug-in cover• Arresting capacity 50 kA (10/350 µs) per pole• Voltage protection level < 2.0 kV• Line following current quenching 25 kA Ipeak• Incl. plug caps for labelling the connections• Encapsulated, non-extinguishing spark gap: can be used in standard distributor housingsApplication example: Industrial plants; lightning arrester in accordance with VDE-AR-N 4100 for pre-meter area. Note: Requires as a decoupling length for surge protection 5 m of cable.
Earthing, lightning and surge protection > Lightning current arrester for power supply systems
TBS Transient and lightning protection systems - OBO BETTERMANN > Surge protection, arrestor, type 1 (industry) - OBO BETTERMANN
Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Arrester surge current (8/20 µs) [total] | 50 kA |
|---|---|
| Blow-out | no |
| CO2 Footprint (GWP) Cradle-to-Gate | 2,0131 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 50 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 10 mm² |
| Dimension | 255V |
| Explosion-tested version | no |
| Follow current quenching capacity (eff) [N-PE] | 10 kA |
| Height | 69 mm |
| Installation type | DIN rail 35 mm |
| Length | 100 mm |
| Lightning protection zone LPZ | 0→1 |
| Lightning surge current (10/350 μs) | 50 kA |
| Lightning surge current (10/350) | 50 kA |
| Max. mains-side overcurrent protection | 500 |
| Maximum back-up fuse | 500 A |
| Maximum continuous voltage AC | 255 V |
| Network form | Other |
| Nominal discharge current (8/20 µs) | 50 kA |
| Nominal voltage AC (50/60 Hz) | 230 V |
|---|---|
| Operating temperature, max. | 85 °C |
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 85 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 1 |
| Protection rating | IP20 |
| Remote signalling | no |
| Response time | <100 ns |
| Short-circuit resistance | 25 kA |
| Short-circuit resistance for max. mains-side overcurrent protection | 25 kA |
| Signalling on device | None |
| SPD to EN 61643-11 | Type 1 |
| SPD to IEC 61643-1 | Class I |
| SPD to UL 1449 | Type 1 |
| Test class, type 1 | yes |
| Version for | 1-pole complete; 255 V |
| Width | 35 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SURGE PROTECTION OBO EN.pdf | 24 Mbytes |
|
| MC 50-B VDE 5096847 OBO BETTERMANN LightningController , UC 255 V, | 49 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.