Data Line Protection ench PDP-P-2-48 Top 2-pole 48V
Cover PDP, 2-pole, 48 V. Plug-in arrester, plug-in data protection type 1+2/D1+C2 for use in instrumentation, control and automation equipment• Protection device for multiwire systems• Frequency range to 100 MHz• Small width of 12.5 mmApplication: Universal lightning and surge protection for data transmission devices in MCR technology.
TBS Transient and lightning protection systems - OBO BETTERMANN
Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Capacity (wire-earth) | ≤30 pF |
|---|---|
| Capacity (wire-wire) | ≤30 pF |
| CO2 Footprint (GWP) Cradle-to-Gate | 0,1219 kg CO2e / 1 Piece |
| Connection cross-section, flexible, max. | 1,5 mm² |
| Connection cross-section, flexible, min. | 0,14 mm² |
| Connection cross-section, multi-wire, max. | 2,5 mm² |
| Connection cross-section, multi-wire, min. | 0,14 mm² |
| Connection cross-section, rigid, max. | 2,5 mm² |
| Connection cross-section, rigid, min. | 0,14 mm² |
| Cut-off frequency | 100 MHz |
| Dimension | 48V |
| Earthing via: | Connection cable / DIN rail |
| Height | 46 mm |
| Impulse durability wire-earth | 10 kV / 5 kA |
| Impulse durability wire-wire | 10 kV / 5 kA |
| Insertion loss | ≤3 dB |
| Kategorie | Type 1+2 / D1+C2 |
| Length | 51 mm |
| Lengthwise resistance | 1.2 ± 5% |
| Lightning impulse current | 2,5 kA |
| Lightning protection zone LPZ | 0→2 |
| Maximum continuous voltage AC | 37 V |
| Maximum continuous voltage DC | 52 V |
|---|---|
| Mounting of input / output | Screw terminals |
| Nominal discharge current (8/20 µs) | 10 kA |
| Nominal load current AC | 0,425 A |
| Nominal load current DC | 0,6 A |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Plug-in system | Terminal |
| Protection level wire-wire | 170 V |
| Protection rating | IP20 |
| Screening | Direct |
| Series resistance per wire | 1,2 Ω ± 5% |
| Shielding connection available | yes |
| Signalling on device | None |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| SPD to IEC 61643-21 | Class I+II / D1+C2 |
| Testing standard | IEC 61643-21 |
| Total discharge current (10/350) | 2,5 kA |
| Total discharge current (8/20) | 20 kA |
| Total impulse durability into C2 (8/20) | 20 kA |
| Width | 13 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SURGE PROTECTION OBO EN.pdf | 24 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.