UNLOADER COMB. BEAM COMPACT
LightningController Compact - MCF75. Combination arrester, lightning current and surge arrester, type 1+2• Protection level ≤ 1.5 kV• For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305)• Lightning current arresting capacity to 75 kA (10/350), 3-pole• Line following current quenching 50 kA Ipeak, arrester backup fuse to 315 A gL/gG• Fulfils the requirements of VDE-AR-N 4100 for use in pre-meter area• Encapsulated, non-extinguishing spark gap arrester for use in distributor housings Application: Industrial systems and buildings with external lightning protection of the highest class I to IV.Compact protection device
TBS Transient and lightning protection systems - OBO BETTERMANN
Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Approvals | VDE, UL |
|---|---|
| Arrester surge current (8/20 µs) [total] | 75 kA |
| CO2 Footprint (GWP) Cradle-to-Gate | 3,7009 kg CO2e / 1 Piece |
| Conductor cross-section, flexible (fine-wire), max. | 3 AWG |
| Conductor cross-section, flexible (fine-wire), max. | 25 mm² |
| Conductor cross-section, flexible (fine-wire), min. | 1,5 mm² |
| Conductor cross-section, flexible (fine-wire), min. | 16 AWG |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 2 AWG |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 16 AWG |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 1,5 mm² |
| Connection cross-section, FM terminals, max. | 16 AWG |
| Connection cross-section, FM terminals, max. | 1,5 mm² |
| Connection cross-section, FM terminals, min. | 28 AWG |
| Connection cross-section, FM terminals, min. | 0,5 mm² |
| Dimension | 255V |
| FM contacts | Changeover |
| Height | 70 mm |
| Housing material surge protection components | PA UL 94 V-0 |
| Installation type | DIN rail 35 mm |
| Length | 90 mm |
| Lightning surge current (10/350 μs) | 25 kA |
| Lightning surge current (10/350) | 75 kA |
| Max. mains-side overcurrent protection | 315 A |
| Maximum back-up fuse | 315 A |
| Maximum continuous voltage AC | 255 V |
| Maximum discharge current (8/20 μs) | 50 kA |
|---|---|
| Network form | TN-C |
| Nominal discharge current (8/20 µs) | 35 kA |
| Nominal voltage AC (50/60 Hz) | 230 V |
| Operating temperature, max. | 80 °C |
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole number | 3 |
| Pole version | 3 |
| Protection rating | IP20 |
| Remote signalling | yes |
| Response time | <100 ns |
| Short-circuit resistance for max. mains-side overcurrent protection | 50 kA eff |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| SPD to UL 1449 | Type 4 |
| Switching power AC | 250V/ 1,5A |
| Switching power DC | 250V/ 0,1A |
| TN network form | yes |
| TN-C network form | yes |
| Torque | 5 Nm |
| TOV voltage [L-N] ‒ fail safe mode ‒ 120 min. | 442 V |
| TOV voltage [L-N] ‒ withstand mode ‒ 5 s | 440 V |
| Width | 107 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SURGE PROTECTION OBO EN.pdf | 24 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.