FRD 5 HF
5098571
OBO BETTERMANN
1
ARRESTER SURGE FRD 5 HF
Combination protection for two-core systems with HF applications 5 V. Surge protection for use in measuring, control and regulation systems.• Basic, medium and fine protection • Two-stage protection circuit with high lightning current carrying capacity • High transmission frequency up to 100 MHz • Suitable for all bus systems (e.g. Profibus) • With installation-friendly, screwless connection terminals • In space-saving 17.5 mm grid Application: Multipurpose use on any 35 mm DIN profile rail in every commercially available distribution housing.
TBS Transient and lightning protection systems - OBO BETTERMANN
Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Approvals | UL |
|---|---|
| Arrestor monitoring | no |
| Capacity (wire-earth) | <40 pF |
| Capacity (wire-wire) | <40 pF |
| CO2 Footprint (GWP) Cradle-to-Gate | 0,1623 kg CO2e / 1 Piece |
| Connection cross-section, flexible, max. | 2,5 mm² |
| Connection cross-section, flexible, min. | 0,14 mm² |
| Connection cross-section, multi-wire, max. | 2,5 mm² |
| Connection cross-section, multi-wire, min. | 0,14 mm² |
| Connection cross-section, rigid, max. | 2,5 mm² |
| Connection cross-section, rigid, min. | 0,14 mm² |
| Cut-off frequency | 100 MHz |
| Dimension | 5V AC |
| Division unit TE (17.5 mm) | 1 |
| Earthing via: | Terminal |
| Explosion-tested version | no |
| Impulse durability wire-earth | C2: 18 kV / 9 kA (8/20µs) |
| Impulse durability wire-wire | C2: 18 kV / 9 kA (8/20µs) |
| Insertion loss | ≤3 dB |
| Insulation resistance | >10 MΩ |
| Kategorie | Type 1+2+3 / D1+C2+C1 |
| Lightning impulse current | 3 kA |
| Lightning protection zone LPZ | 0→3 |
|---|---|
| Maximum continuous voltage AC | 4 V |
| Maximum continuous voltage DC | 6 V |
| Nominal discharge current (8/20 µs) | 9 kA |
| Nominal load current AC | 0,32 A |
| Nominal load current DC | 0,45 A |
| Nominal voltage | 5 V |
| Number of poles | 2 |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Plug-in system | Terminal |
| Protection level wire-earth | <650 V |
| Protection level wire-wire | <90 V |
| Protection rating | IP20 |
| Series resistance per wire | 2,2 Ω ± 10 % |
| Shielding connection available | no |
| SPD to IEC 61643-21 | Class I+II+III / D1+C2+C1 |
| Telecommunications contact | no |
| Testing standard | IEC 61643-21 |
| Total discharge current (10/350) | D1: 6 kA |
| Total discharge current (8/20) | 18 kA |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SURGE PROTECTION OBO EN.pdf | 24 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.