5096874 OBO BETTERMANN DOWNLOADER T. 1 MCD 50-B 3-VG View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

5096874 OBO BETTERMANN DOWNLOADER T. 1 MCD 50-B 3-VG

MCD 50-B 3-VG

5096874

OBO BETTERMANN

DOWNLOADER T. 1 MCD 50-B 3-VG

VG housing with MCD 50-B/3. Combination arrester, pre-installed in IP65 housing for use in TN-C networks.VG...: Combination arrester system solution, type 1+2, according to EN 61643-11. • LightningController MCD 50-B mounted in insulating housing IP 65, sealable housing• Pulse current 150 kA 10/350 µs / 50 kA (10/350) per pole, BET-tested• Protection level < 1.7 kV• Encapsulated, non-extinguishing spark gaps• Suitable for TN-C network systems Application: Industrial systems and buildings with external lightning protection of the highest Class I to IV.

More details


Earthing, lightning and surge protection > Lightning current arrester for power supply systems

TBS Transient and lightning protection systems - OBO BETTERMANN

Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Arrester surge current (8/20 µs) [total]150 kA
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate6,7355 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.50 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.10 mm²
Dimension255V
Height170 mm
Installation typePre-mounted in the housing
Length300 mm
Lightning protection zone LPZ0→2
Lightning surge current (10/350 μs)50 kA
Lightning surge current (10/350)150 kA
Max. mains-side overcurrent protection500
Maximum back-up fuse500 A
Maximum continuous voltage AC255 V
Network formTN-C
Nominal discharge current (8/20 µs)50 kA
Nominal voltage AC (50/60 Hz)230 V
OBO_Nominal load current (input/output terminal)125 A
Operating temperature, max.85 °C
Operating temperature, min.-40 °C
Permitted temperature range, max.85 °C
Permitted temperature range, min.-40 °C
Pole version3
Protection level [L-N]≤1,7
Protection ratingIP54
Remote signallingyes
Response time<100 ns
Short-circuit resistance10 kA
Short-circuit resistance for max. mains-side overcurrent protection10 kA
Signalling on deviceNone
SPD to EN 61643-11Type 1+2
SPD to IEC 61643-1Class I+II
Test class, type 1yes
Test class, type 2yes
TN network formyes
TN-C network formyes
Width300 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.