PHOENIX CONTACT  PT 2,5-4L/1P-FS 3012302 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

PT 2,5-4L/1P-FS 3012302 PHOENIX CONTACT Flange

Reference: PT 2,5-4L/1P-FS

Code: 3012302

Manufacturer: PHOENIX CONTACT

Description:

Flange
Flange, length: 105.6 mm, width: 5.2 mm, colour: grey
Flange, width: 5.2 mm, height: 105.6 mm, color: gray

Categories:

  • Terminal blocks > End bracket for terminal block
  • PHOENIX CONTACT > Modular TBs

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Total: 24,14 €

Unit Price: 2,414 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 2-3 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

Technical data

Product properties
Product typeFlange
Data management status
Article revision02

Dimensions
Width5.2 mm
End cover width2.2 mm
Height105.6 mm
Depth on NS 35/7,559 mm
Depth on NS 35/1566.5 mm

Material specifications
Colorgray (RAL 7042)
MaterialPA
Flammability rating according to UL 94V0
Static insulating material application in cold-60 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Electrical tests
Surge voltage test
ResultTest passed
Temperature-rise test
Requirement temperature-rise testIncrease in temperature ≤ 45 K
ResultTest passed
Short-time withstand current 2.5 mm²0.3 kA
ResultTest passed
Power-frequency withstand voltage
Test voltage setpoint1.89 kV
ResultTest passed

Mechanical tests
Mechanical strength
ResultTest passed
Attachment on the carrier
ResultTest passed
Test for conductor damage and slackening
Rotation speed10 rpm
Revolutions135
Conductor cross section/weight0.14 mm² / 0.2 kg
2.5 mm² / 0.7 kg
4 mm² / 0.9 kg
ResultTest passed

Environmental and real-life conditions
Aging
Temperature cycles192
ResultTest passed
Needle-flame test
Time of exposure30 s
ResultTest passed
Oscillation/broadband noise
SpecificationDIN EN 50155 (VDE 0115-200):2022-06
SpectrumService life test category 1, class B, body mounted
Frequencyf1= 5 Hz to f2= 150 Hz
ASD level0.964 (m/s²)²/Hz
Acceleration0.58g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
ResultTest passed
Shocks
SpecificationDIN EN 50155 (VDE 0115-200):2022-06
Pulse shapeHalf-sine
Acceleration5g
Shock duration30 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
ResultTest passed
Ambient conditions
Ambient temperature (operation)-60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (storage/transport)30 % ... 70 %

ETIM for 3012302 Terminal blocks (EC001041)

Feature nameColour (EF000007)
Feature valueGrey
Feature nameMaterial (EF002169)
Feature valueOther
Feature nameMaterial quality (EF001257)
Feature valuePolyamide (PA)
Feature nameInflammability class of insulation material according to UL94 (EF002521)
Feature valueV0
Feature nameHeight (EF000040)
Feature value105.6 mm
Feature nameDepth (EF000049)
Feature value59 mm

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.