HSP-200-4.2 MEANWELL AC-DC Single output enclosed power supply with PCF, Output 4.2VDC / 40A, 1U low profile..

HSP-200-4.2

MEANWELL

Available Ship on today

AC-DC Single output enclosed power supply with PCF, Output 4.2VDC / 40A, 1U low profile, conformal coated

More details


PFC > HSP

* Brand new product in its original packaging covered by the warranties and certifications provided by MEANWELL

Total price: $53.83
Unit price: $53.83

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



200W Single Output with PFC Function 200W Single Output with PFC Function
200W Single Output with PFC Function HSP-200series HSP-200series
HSP-200series Features : Features :
Features : UniversalAC input / Full range UniversalAC input / Full range
UniversalAC input / Full range Built-in active PFC function Built-in active PFC function
Built-in active PFC function Low leakage current<1.0mA Low leakage current<1.0mA
Low leakage current<1.0mA Protections: Short circuit / Overload / Over voltage/ Over temperature Protections: Short circuit / Overload / Over voltage/ Over temperature
Protections: Short circuit / Overload / Over voltage/ Over temperature Low profile:31mm Low profile:31mm
Low profile:31mm Conformalcoated Conformalcoated
Conformalcoated LED indicator for power on LED indicator for power on
LED indicator for power on 3 years warranty 3 years warranty
3 years warrantySPECIFICATION SPECIFICATION
SPECIFICATION Bauar t gepr u f t Bauar t gepr u f t
Bauar t gepr u f t Sicherheit egel ma ge Sicherheit egel ma ge
Sicherheit egel ma ge od o s od o s
od o s be wacg be wacg
be wacg www. tuv. com www. tuv. com
www. tuv. com ID 2000000000 ID 2000000000
ID 2000000000 MODEL MODEL
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE DC VOLTAGE RATED CURRENT CURRENT RANGE
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER(convection) RATED POWER(convection)
RATED POWER(convection) HSP-200-4.2 HSP-200-4.2
HSP-200-4.2 4.2V 4.2V
4.2V 40A 40A
40A 0 ~ 40A 0 ~ 40A
0 ~ 40A 168W 168W
168W HSP-200-5 HSP-200-5
HSP-200-5 5V 5V
5V 40A 40A
40A 0 ~ 40A 0 ~ 40A
0 ~ 40A 200W 200W
200W RIPPLE & NOISE (max.) Note.2150mVp-p RIPPLE & NOISE (max.) Note.2150mVp-p
RIPPLE & NOISE (max.) Note.2150mVp-p 150mVp-p 150mVp-p
150mVp-p OUTPUT OUTPUT
OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3
VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LINE REGULATION
LINE REGULATION LOAD REGULATION LOAD REGULATION
LOAD REGULATION 3.6~4.4V 3.6~4.4V
3.6~4.4V 2.0% 2.0%
2.0% 0.5% 0.5%
0.5% 1.0% 1.0%
1.0% 4.5~5.5V 4.5~5.5V
4.5~5.5V 2.0% 2.0%
2.0% 0.5% 0.5%
0.5% 1.0% 1.0%
1.0% SETUP, RISE TIME HOLD UP TIME (Typ.) SETUP, RISE TIME HOLD UP TIME (Typ.)
SETUP, RISE TIME HOLD UP TIME (Typ.) 2000ms, 200ms/230VAC 3000ms, 200ms/115VAC at full load 2000ms, 200ms/230VAC 3000ms, 200ms/115VAC at full load
2000ms, 200ms/230VAC 3000ms, 200ms/115VAC at full load 16ms/230VAC16ms/115VAC at full load 16ms/230VAC16ms/115VAC at full load
16ms/230VAC16ms/115VAC at full load VOLTAGE RANGE Note.4 90 ~ 264VAC127 ~ 370VDC VOLTAGE RANGE Note.4 90 ~ 264VAC127 ~ 370VDC
VOLTAGE RANGE Note.4 90 ~ 264VAC127 ~ 370VDC INPUT INPUT
INPUT FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.)
FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT
AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 47 ~ 63Hz 47 ~ 63Hz
47 ~ 63Hz PF0.95/230VACPF 0.98/115VAC at full load PF0.95/230VACPF 0.98/115VAC at full load
PF0.95/230VACPF 0.98/115VAC at full load 88% 88%
88% 2.5A/115VAC 1.5A/230VAC Cold start 70A/230VAC 2.5A/115VAC 1.5A/230VAC Cold start 70A/230VAC
2.5A/115VAC 1.5A/230VAC Cold start 70A/230VAC <1.0mA / 240VAC <1.0mA / 240VAC
<1.0mA / 240VAC 110~140% rated output power 110~140% rated output power
110~140% rated output power88.5% 88.5%
88.5% 3.0A/115VAC 2.0A/230VAC 3.0A/115VAC 2.0A/230VAC
3.0A/115VAC 2.0A/230VAC OVERLOAD OVERLOAD
OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION PROTECTION
PROTECTION 4.6 ~ 5.4V 4.6 ~ 5.4V
4.6 ~ 5.4V 5.6 ~ 7.0V 5.6 ~ 7.0V
5.6 ~ 7.0VENVIRONMENT ENVIRONMENT
ENVIRONMENT SAFETY & EMC SAFETY & EMC
SAFETY & EMC (Note 5) (Note 5)
(Note 5) OTHERS OTHERS
OTHERS OVER VOLTAGE OVER VOLTAGE
OVER VOLTAGEOVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY
OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY STORAGE TEMP., HUMIDITY
STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION TEMP. COEFFICIENT VIBRATION
TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY STANDARDS
SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION EMC IMMUNITY MTBF DIMENSION
EMC IMMUNITY MTBF DIMENSION PACKING PACKING
PACKING Protection type : Hiccup mode, recovers automatically after fault condition is removed Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed Shut down O/P voltage, recovers automatically after fault condition is removed Shut down O/P voltage, recovers automatically after fault condition is removed
Shut down O/P voltage, recovers automatically after fault condition is removed -30 ~ +70(Refer to "Derating Curve") -30 ~ +70(Refer to "Derating Curve")
-30 ~ +70(Refer to "Derating Curve") 20 ~ 90% RH non-condensing 20 ~ 90% RH non-condensing
20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH -40 ~ +85, 10 ~ 95% RH
-40 ~ +85, 10 ~ 95% RH 0.03%/ (0 ~ 60) 0.03%/ (0 ~ 60)
0.03%/ (0 ~ 60) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1,TUV EN60950-1,CCC GB4943 approved UL60950-1,TUV EN60950-1,CCC GB4943 approved
UL60950-1,TUV EN60950-1,CCC GB4943 approved I/P-O/P:3.0KVAC I/P-FG:2KVACO/P-FG:0.5KVAC I/P-O/P:3.0KVAC I/P-FG:2KVACO/P-FG:0.5KVAC
I/P-O/P:3.0KVAC I/P-FG:2KVACO/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25/ 70%RH I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25/ 70%RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25/ 70%RH Compliance to EN55022 (CISPR22),GB9254,Class B, EN61000-3-2,-3,GB17625.1 Compliance to EN55022 (CISPR22),GB9254,Class B, EN61000-3-2,-3,GB17625.1
Compliance to EN55022 (CISPR22),GB9254,Class B, EN61000-3-2,-3,GB17625.1 Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024, light industry level (surge 4KV),criteria A Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024, light industry level (surge 4KV),criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024, light industry level (surge 4KV),criteria A 204K hrs min.MIL-HDBK-217F (25) 204K hrs min.MIL-HDBK-217F (25)
204K hrs min.MIL-HDBK-217F (25) 210*62*31mm (L*W*H) 210*62*31mm (L*W*H)
210*62*31mm (L*W*H) 0.52kg;20pcs/ 11.4kg/0.76CUFT 0.52kg;20pcs/ 11.4kg/0.76CUFT
0.52kg;20pcs/ 11.4kg/0.76CUFT NOTE NOTE
NOTE 1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25 of ambient temperature. 1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25 of ambient temperature.
1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25 of ambient temperature. 2. Ripple & noiseare measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Ripple & noiseare measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Ripple & noiseare measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : line regulation and load regulation. 3. Tolerance : line regulation and load regulation.
3. Tolerance : line regulation and load regulation. 4. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details. 4. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details.
4. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details. 5. Lengthof setup time is measured at cold first start.Turning ON/OFF the powersupply may leadto increase of the setup time. 5. Lengthof setup time is measured at cold first start.Turning ON/OFF the powersupply may leadto increase of the setup time.
5. Lengthof setup time is measured at cold first start.Turning ON/OFF the powersupply may leadto increase of the setup time. 6. The powersupply is considered a component which will be installedinto a final equipment. All the EMC tests are been executed by mountingthe unit on a 450mm*450mm metalplate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to performthese EMC tests, please refer to "EMI testingof component powersupplies." (as available on http://www.meanwell.com) 6. The powersupply is considered a component which will be installedinto a final equipment. All the EMC tests are been executed by mountingthe unit on a 450mm*450mm metalplate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to performthese EMC tests, please refer to "EMI testingof component powersupplies." (as available on http://www.meanwell.com)
6. The powersupply is considered a component which will be installedinto a final equipment. All the EMC tests are been executed by mountingthe unit on a 450mm*450mm metalplate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to performthese EMC tests, please refer to "EMI testingof component powersupplies." (as available on http://www.meanwell.com)File Name:HSP-200-SPEC2016-01-21 File Name:HSP-200-SPEC2016-01-21
File Name:HSP-200-SPEC2016-01-21

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.