200W Single Output LED Power SupplyHLG-185H-Cseries
200W Single Output LED Power SupplyHLG-185H-Cseries
200W Single Output LED Power SupplyHLG-185H-CseriesFeatures :
Features :
Features :
Constant currentdesign
Constant currentdesign
Constant currentdesign
Universal AC input / Full range (up to 305VAC)
Universal AC input / Full range (up to 305VAC)
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Built-in active PFC function
Built-in active PFC function
High efficiency up to 94%
High efficiency up to 94%
High efficiency up to 94%
Protections: Short circuit / Over voltage/ Over temperature
Protections: Short circuit / Over voltage/ Over temperature
Protections: Short circuit / Over voltage/ Over temperature
Cooling by free air convection
Cooling by free air convection
Cooling by free air convection
Output currentadjustable throughoutput cableor internal potentiometer
Output currentadjustable throughoutput cableor internal potentiometer
Output currentadjustable throughoutput cableor internal potentiometer
IP67 / IP65 design for indoor or outdoorinstallations
IP67 / IP65 design for indoor or outdoorinstallations
IP67 / IP65 design for indoor or outdoorinstallations
Three in one dimming function (1=10Vdcor 10V PWM signal or resistance)
Three in one dimming function (1=10Vdcor 10V PWM signal or resistance)
Three in one dimming function (1=10Vdcor 10V PWM signal or resistance)
Suitable for dry / damp/ wet locations
Suitable for dry / damp/ wet locations
Suitable for dry / damp/ wet locations
7 years warranty (Note.5)
7 years warranty (Note.5)
7 years warranty (Note.5)F110
F110
F110MM IP65 IP67
MM IP65 IP67
MM IP65 IP67HLG-185H-C500 A
HLG-185H-C500 A
HLG-185H-C500 A
A : IP65 rated.Constant currentlevel can be adjusted throughinternal potentiometer.
A : IP65 rated.Constant currentlevel can be adjusted throughinternal potentiometer.
A : IP65 rated.Constant currentlevel can be adjusted throughinternal potentiometer.
B : IP67 rated. Constantcurrent level adjustablethrough output cable with 1=10Vdc or 10V PWM signal or resistance. D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
B : IP67 rated. Constantcurrent level adjustablethrough output cable with 1=10Vdc or 10V PWM signal or resistance. D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
B : IP67 rated. Constantcurrent level adjustablethrough output cable with 1=10Vdc or 10V PWM signal or resistance. D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.SPECIFICATION
SPECIFICATION
SPECIFICATION
MODEL
MODEL
MODEL
RATED CURRENT CURRENT ACCURACY
RATED CURRENT CURRENT ACCURACY
RATED CURRENT CURRENT ACCURACY
HLG-185H-C500 HLG-185H-C700 HLG-185H-C1050 HLG-185H-C1400
HLG-185H-C500 HLG-185H-C700 HLG-185H-C1050 HLG-185H-C1400
HLG-185H-C500 HLG-185H-C700 HLG-185H-C1050 HLG-185H-C1400
500mA 700mA 1050mA 1400mA
500mA 700mA 1050mA 1400mA
500mA 700mA 1050mA 1400mA
5.0%
5.0%
5.0%
CONSTANT CURRENT REGION Note.6 200V ~ 400V 143V ~ 286V 95V ~ 190V 71V ~ 143V
CONSTANT CURRENT REGION Note.6 200V ~ 400V 143V ~ 286V 95V ~ 190V 71V ~ 143V
CONSTANT CURRENT REGION Note.6 200V ~ 400V 143V ~ 286V 95V ~ 190V 71V ~ 143V
RATED POWER RIPPLE CURRENT
RATED POWER RIPPLE CURRENT
RATED POWER RIPPLE CURRENT
200W 200.2W199.5W200.2W
200W 200.2W199.5W200.2W
200W 200.2W199.5W200.2W
5%
5%
5%
OUTPUT
OUTPUT
OUTPUT
RIPPLE & NOISE 2Vp-p 1.5Vp-p 1Vp-p 1Vp-p
RIPPLE & NOISE 2Vp-p 1.5Vp-p 1Vp-p 1Vp-p
RIPPLE & NOISE 2Vp-p 1.5Vp-p 1Vp-p 1Vp-p
Can be adjusted by internal potentiometer (A type only)
Can be adjusted by internal potentiometer (A type only)
Can be adjusted by internal potentiometer (A type only)
CURRENT ADJ. RANGE
CURRENT ADJ. RANGE
CURRENT ADJ. RANGE
250 ~ 500mA
250 ~ 500mA
250 ~ 500mA
350 ~ 700mA 525 ~ 1050mA
350 ~ 700mA 525 ~ 1050mA
350 ~ 700mA 525 ~ 1050mA
700 ~ 1400mA
700 ~ 1400mA
700 ~ 1400mA
LINE REGULATION
LINE REGULATION
LINE REGULATION
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
SETUP, RISE TIME HOLD UP TIME (Typ.)
SETUP, RISE TIME HOLD UP TIME (Typ.)
SETUP, RISE TIME HOLD UP TIME (Typ.)
1000ms, 80ms / 115VAC at full load500ms, 80ms / 230VAC at full load
1000ms, 80ms / 115VAC at full load500ms, 80ms / 230VAC at full load
1000ms, 80ms / 115VAC at full load500ms, 80ms / 230VAC at full load
16ms at full load 230VAC / 115VAC
16ms at full load 230VAC / 115VAC
16ms at full load 230VAC / 115VAC
VOLTAGE RANGE Note.2 90 ~ 305VAC127VDC ~ 431VDC
VOLTAGE RANGE Note.2 90 ~ 305VAC127VDC ~ 431VDC
VOLTAGE RANGE Note.2 90 ~ 305VAC127VDC ~ 431VDC
FREQUENCY RANGE POWER FACTOR (Typ.)
FREQUENCY RANGE POWER FACTOR (Typ.)
FREQUENCY RANGE POWER FACTOR (Typ.)
47 ~ 63Hz
47 ~ 63Hz
47 ~ 63Hz
PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)INPUT
INPUT
INPUT
TOTAL HARMONIC DISTORTION THD< 20% when output loading50% at 115VAC/230VAC input and output loading75% at 277VAC input
TOTAL HARMONIC DISTORTION THD< 20% when output loading50% at 115VAC/230VAC input and output loading75% at 277VAC input
TOTAL HARMONIC DISTORTION THD< 20% when output loading50% at 115VAC/230VAC input and output loading75% at 277VAC input
EFFICIENCY (Typ.)
EFFICIENCY (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
MAX. No. of PSUs on 16A
MAX. No. of PSUs on 16A
MAX. No. of PSUs on 16A
94% 94% 94% 94%
94% 94% 94% 94%
94% 94% 94% 94%
2A / 115VAC 1A / 230VAC 0.85A / 277VAC
2A / 115VAC 1A / 230VAC 0.85A / 277VAC
2A / 115VAC 1A / 230VAC 0.85A / 277VAC
COLD START 55A(twidth=900s measured at 50% Ipeak) at 230VAC
COLD START 55A(twidth=900s measured at 50% Ipeak) at 230VAC
COLD START 55A(twidth=900s measured at 50% Ipeak) at 230VAC
CIRCUIT BREAKER2 units (circuit breaker of type B) / 3 units(circuit breaker of type C) at 230VAC
CIRCUIT BREAKER2 units (circuit breaker of type B) / 3 units(circuit breaker of type C) at 230VAC
CIRCUIT BREAKER2 units (circuit breaker of type B) / 3 units(circuit breaker of type C) at 230VACPROTECTION
PROTECTION
PROTECTION
ENVIRONMENT
ENVIRONMENT
ENVIRONMENT
LEAKAGE CURRENT SHORT CIRCUIT
LEAKAGE CURRENT SHORT CIRCUIT
LEAKAGE CURRENT SHORT CIRCUIT
OVER VOLTAGE
OVER VOLTAGE
OVER VOLTAGEOVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY
OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY
OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
STORAGE TEMP., HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT VIBRATION
TEMP. COEFFICIENT VIBRATION
TEMP. COEFFICIENT VIBRATION
<0.75mA / 277VAC
<0.75mA / 277VAC
<0.75mA / 277VAC
Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
450 ~ 470V 320 ~ 340V 210 ~ 225V 160 ~ 170V Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
450 ~ 470V 320 ~ 340V 210 ~ 225V 160 ~ 170V Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
450 ~ 470V 320 ~ 340V 210 ~ 225V 160 ~ 170V Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
Shut down o/p voltage, recovers automatically after temperature goes down
Shut down o/p voltage, recovers automatically after temperature goes down
Shut down o/p voltage, recovers automatically after temperature goes down
-40 ~ +70c (Refer to "Derating Curve")
-40 ~ +70c (Refer to "Derating Curve")
-40 ~ +70c (Refer to "Derating Curve")
10 ~ 95% RH non-condensing
10 ~ 95% RH non-condensing
10 ~ 95% RH non-condensing
-40 ~ +80c, 10 ~ 95% RH
-40 ~ +80c, 10 ~ 95% RH
-40 ~ +80c, 10 ~ 95% RH
0.03%/c (0 ~ 50c)
0.03%/c (0 ~ 50c)
0.03%/c (0 ~ 50c)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.3 UL8750, CSA C22.2 No. 250.12-13, ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP65 or IP67, J61347-1, J61347-2-13 approved
SAFETY STANDARDS Note.3 UL8750, CSA C22.2 No. 250.12-13, ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP65 or IP67, J61347-1, J61347-2-13 approved
SAFETY STANDARDS Note.3 UL8750, CSA C22.2 No. 250.12-13, ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP65 or IP67, J61347-1, J61347-2-13 approvedSAFETY & EMC
SAFETY & EMC
SAFETY & EMCOTHERS
OTHERS
OTHERS
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
EMC IMMUNITY MTBF DIMENSION
EMC IMMUNITY MTBF DIMENSION
EMC IMMUNITY MTBF DIMENSION
PACKING
PACKING
PACKING
I/P-O/P:3.75KVAC I/P-FG:2KVACO/P-FG:1.5KVAC
I/P-O/P:3.75KVAC I/P-FG:2KVACO/P-FG:1.5KVAC
I/P-O/P:3.75KVAC I/P-FG:2KVACO/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25c/ 70% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25c/ 70% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25c/ 70% RH
Compliance to EN55015, EN61000-3-2 Class C (50% load) ; EN61000-3-3
Compliance to EN55015, EN61000-3-2 Class C (50% load) ; EN61000-3-3
Compliance to EN55015, EN61000-3-2 Class C (50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge L,N-FG: 4KV), criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge L,N-FG: 4KV), criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge L,N-FG: 4KV), criteria A
191.9K hrs min.MIL-HDBK-217F (25c)
191.9K hrs min.MIL-HDBK-217F (25c)
191.9K hrs min.MIL-HDBK-217F (25c)
228*68*38.8mm (L*W*H)
228*68*38.8mm (L*W*H)
228*68*38.8mm (L*W*H)
1.15Kg; 12pcs/14.8Kg/0.8CUFT
1.15Kg; 12pcs/14.8Kg/0.8CUFT
1.15Kg; 12pcs/14.8Kg/0.8CUFTNOTE
NOTE
NOTE
1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25c of ambient temperature.
1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25c of ambient temperature.
1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25c of ambient temperature.
2. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details.
2. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details.
2. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details.
3. Safetyand EMC design refer to EN60598-1, CNS15233, GB7000.1.
3. Safetyand EMC design refer to EN60598-1, CNS15233, GB7000.1.
3. Safetyand EMC design refer to EN60598-1, CNS15233, GB7000.1.
4. The powersupply is considered as a component that will be operated in combination with final equipment. SinceEMC performance will be affected by the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain.
4. The powersupply is considered as a component that will be operated in combination with final equipment. SinceEMC performance will be affected by the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain.
4. The powersupply is considered as a component that will be operated in combination with final equipment. SinceEMC performance will be affected by the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain.
5. Referto warrantystatement.
5. Referto warrantystatement.
5. Referto warrantystatement.
6. Please refer to "DRIVING METHODS OF LED MODULE".
6. Please refer to "DRIVING METHODS OF LED MODULE".
6. Please refer to "DRIVING METHODS OF LED MODULE".
7. To fulfill requirements of the latestErP regulation for lighting fixtures, this LED power supply canonly be used behinda switch without permanently connected to the mains.
7. To fulfill requirements of the latestErP regulation for lighting fixtures, this LED power supply canonly be used behinda switch without permanently connected to the mains.
7. To fulfill requirements of the latestErP regulation for lighting fixtures, this LED power supply canonly be used behinda switch without permanently connected to the mains.
File Name:HLG-185H-C-SPEC2015-07-23
File Name:HLG-185H-C-SPEC2015-07-23
File Name:HLG-185H-C-SPEC2015-07-23