12.5~30W DC-DC Non-isolated Single Output Converter NID30series
12.5~30W DC-DC Non-isolated Single Output Converter NID30series
12.5~30W DC-DC Non-isolated Single Output Converter NID30series SPECIFICATION
SPECIFICATION
SPECIFICATION
ORDER NO.
ORDER NO.
ORDER NO.
DC VOLTAGE CURRENT RANGE
DC VOLTAGE CURRENT RANGE
DC VOLTAGE CURRENT RANGE
RATED POWER
RATED POWER
RATED POWER
Features :
Features :
Features :
Economic open frame design
Economic open frame design
Economic open frame design
Wide input range
Wide input range
Wide input range
High efficiency, up to 96%
High efficiency, up to 96%
High efficiency, up to 96%
Built-in remote ON / OFF control
Built-in remote ON / OFF control
Built-in remote ON / OFF control
Compact size 2.0"x0.512"x0.421"(SIP package)
Compact size 2.0"x0.512"x0.421"(SIP package)
Compact size 2.0"x0.512"x0.421"(SIP package)
Cooling by free air convection
Cooling by free air convection
Cooling by free air convection
Protections: short circuit / Overload / Over voltage
Protections: short circuit / Overload / Over voltage
Protections: short circuit / Overload / Over voltage
100% burn-in test
100% burn-in test
100% burn-in test
Low cost / High reliability
Low cost / High reliability
Low cost / High reliability
2 years warranty
2 years warranty
2 years warrantyNID30S24-05NID30S24-12NID30S24-15NID30S48-24
NID30S24-05NID30S24-12NID30S24-15NID30S48-24
NID30S24-05NID30S24-12NID30S24-15NID30S48-24
5V12V15V24V
5V12V15V24V
5V12V15V24V
0 ~ 2.5 0 ~ 2.5 0 ~ 2A0 ~ 1,25
0 ~ 2.5 0 ~ 2.5 0 ~ 2A0 ~ 1,25
0 ~ 2.5 0 ~ 2.5 0 ~ 2A0 ~ 1,25
12.5W30W 30W 30W
12.5W30W 30W 30W
12.5W30W 30W 30WOUTPUT
OUTPUT
OUTPUT
RIPPLE & NOISE (max.) Note.2100mVp-p 120mVp-p 150mVp-p 200mVp-p
RIPPLE & NOISE (max.) Note.2100mVp-p 120mVp-p 150mVp-p 200mVp-p
RIPPLE & NOISE (max.) Note.2100mVp-p 120mVp-p 150mVp-p 200mVp-p
LINE REGULATIONNote.30.5%
LINE REGULATIONNote.30.5%
LINE REGULATIONNote.30.5%
LOAD REGULATIONNote.40.5%
LOAD REGULATIONNote.40.5%
LOAD REGULATIONNote.40.5%
VOLTAGE ACCURACY
VOLTAGE ACCURACY
VOLTAGE ACCURACY
2.0%
2.0%
2.0%
SWITCHING FREQUENCY (Typ.) 250KHz
SWITCHING FREQUENCY (Typ.) 250KHz
SWITCHING FREQUENCY (Typ.) 250KHz
EXTERNAL CAPACITANCE LOAD (max.) 100uF / 25V low ESR
EXTERNAL CAPACITANCE LOAD (max.) 100uF / 25V low ESR
EXTERNAL CAPACITANCE LOAD (max.) 100uF / 25V low ESR68uf/16V low ESR
68uf/16V low ESR
68uf/16V low ESR47uf/50V low ESR
47uf/50V low ESR
47uf/50V low ESR
INPUT
INPUT
INPUT
VOLTAGE RANGE NORMAL VOLTAGE EFFICIENCY (Typ.)
VOLTAGE RANGE NORMAL VOLTAGE EFFICIENCY (Typ.)
VOLTAGE RANGE NORMAL VOLTAGE EFFICIENCY (Typ.)THE DC CURRENT
THE DC CURRENT
THE DC CURRENT
20 ~ 53VDC
20 ~ 53VDC
20 ~ 53VDC
24VDC (or 48VDC)
24VDC (or 48VDC)
24VDC (or 48VDC)
91% of the load590mA No load 20mA
91% of the load590mA No load 20mA
91% of the load590mA No load 20mA
20 ~ 53VDC
20 ~ 53VDC
20 ~ 53VDC
24VDC (or 48VDC)
24VDC (or 48VDC)
24VDC (or 48VDC)
95%
95%
95%
1310mA
1310mA
1310mA
30mA
30mA
30mA
20 ~ 53VDC
20 ~ 53VDC
20 ~ 53VDC
24VDC (or 48VDC)
24VDC (or 48VDC)
24VDC (or 48VDC)
96%
96%
96%
1320mA
1320mA
1320mA
30mA
30mA
30mA
30 ~ 53VDC
30 ~ 53VDC
30 ~ 53VDC
48VDC
48VDC
48VDC
93%
93%
93%
700mA
700mA
700mA
50mA
50mA
50mA
PROTECTION Fuse recommended (3A)
PROTECTION Fuse recommended (3A)
PROTECTION Fuse recommended (3A)
120 ~ 300%rated output power
120 ~ 300%rated output power
120 ~ 300%rated output power
PROTECTION
PROTECTION
PROTECTIONENVIRONMENT
ENVIRONMENT
ENVIRONMENTOTHERS
OTHER
OTHER
OVERLOAD (Typ.)
OVERLOAD (Typ.)
OVERLOAD (Typ.)SHORT CIRCUIT OVER VOLTAGE
SHORT CIRCUIT OVER VOLTAGE
SHORT CIRCUIT OVER VOLTAGE
WORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
WORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
WORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
REMOTE CONTROL OF THE DIMENSION
REMOTE CONTROL OF THE DIMENSION
REMOTE CONTROL OF THE DIMENSION
WEIGHT
WEIGHT
WEIGHT
Protection type :Hiccup mode, recovers automatically after fault condition is removed
Protection type :Hiccup mode, recovers automatically after fault condition is removed
Protection type :Hiccup mode, recovers automatically after fault condition is removed
All output equipped with short circuit
All output equipped with short circuit
All output equipped with short circuit
Protection type :Hiccup mode, recovers automatically after fault condition is removed
Protection type :Hiccup mode, recovers automatically after fault condition is removed
Protection type :Hiccup mode, recovers automatically after fault condition is removed
Protection type :Shut off o/p voltage, clamp by TVS diode
Protection type :Shut off o/p voltage, clamp by TVS diode
Protection type :Shut off o/p voltage, clamp by TVS diode
-25 ~ +65 (Refer to "Reduction Curve")
-25 ~ +65 (Refer to "Reduction Curve")
-25 ~ +65 (Refer to "Reduction Curve")
20% ~ 85%RHnon-condensing
20% ~ 85%RHnon-condensing
20% ~ 85%RHnon-condensing
-25 ~ +105, 10 ~ 85% RH
-25 ~ +105, 10 ~ 85% RH
-25 ~ +105, 10 ~ 85% RH
0.03% /(0 ~ 50)
0.03% /(0 ~ 50)
0.03% /(0 ~ 50)
10 ~ 500Hz, 2G 10min./1 cycle, period for 60 min. eachalongX, y, Z axes
10 ~ 500Hz, 2G 10min./1 cycle, period for 60 min. eachalongX, y, Z axes
10 ~ 500Hz, 2G 10min./1 cycle, period for 60 min. eachalongX, y, Z axes
Power supply : 3.3 VDC < R. C ~ com < 12VDC or open circuit ; power off : R. C ~ com < 0.4 vdc or short circuit (PIN 5,6 & PIN11)
Power supply : 3.3 VDC < R. C ~ com < 12VDC or open circuit ; power off : R. C ~ com < 0.4 vdc or short circuit (PIN 5,6 & PIN11)
Power supply : 3.3 VDC < R. C ~ com < 12VDC or open circuit ; power off : R. C ~ com < 0.4 vdc or short circuit (PIN 5,6 & PIN11)
50.8*13*10.7 mm or 2.0"*0.512"*0.421" inch (L*W*H)
50.8*13*10.7 mm or 2.0"*0.512"*0.421" inch (L*W*H)
50.8*13*10.7 mm or 2.0"*0.512"*0.421" inch (L*W*H)
8g
8g
8gMechanical Specification
Mechanical Specification
Mechanical Specification
Unit:mm(in.)
Unit:mm(in.)
Unit:mm(inch)10.7[0.421]max.
10.7[0.421]max.
10.7[0.421]max.Pin Configuration Of The Curve Of Reduction Of Power
Pin Configuration Of The Curve Of Reduction Of Power
Pin Configuration Of The Curve Of Reduction Of Power
Pin No. Output
Pin No. Output
Pin No. Output
50.8 [2]
50.8 [2]
50.8 [2]1 234 5 67 89 1011
1 234 5 67 89 1011
1 234 5 67 89 1011
8 [0.315]
8 [0.315]
8 [0.315]
SIDE VIEW
SIDE VIEW
SIDE VIEW
1,2,3,4
1,2,3,4
1,2,3,4
5,6
5,6
5,6
7,8
7,8
7,8
9,10
9,10
9,10
11
11
Eleven
+V
+V
+V
Com
Com
Com
+V in N. C. reinforced concrete
+V in N. C. reinforced concrete
+V in N. C. reinforced concrete 100
100
Ten thousand eighty
80
Eighty
50
50
50 0.64 [0.025]
0.64 [0.025]
0.64 [0.025]
10.2 [0.402] 25.4 [1]
10.2 [0.402] 25.4 [1]
10.2 [0.402] 25.4 [1] 1.3 [0.051]
1.3 [0.051]
1.3 [0.051] 2.54 [0.1]
2.54 [0.1]
2.54 [0.1]4[0.16]
4[0.16]
4[0.16]-25 0 25 55 6065 100
-25 0 25 55 100 6065
-25 0 25 55 6065 100Ta ()
Ta ()
Ta ()NOTE
NOTE
NOTE
1.All the parameters are specified in normalinput, rated load, 25 70% rh Ambient.
1.All the parameters are specified in normalinput, rated load, 25 70% rh Ambient.
1.All the parameters are specified in normalinput, rated load, 25 70% rh Ambient.
2.Ripple and noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 uf and capacitor of 47uf.
2.Ripple and noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 uf and capacitor of 47uf.
2.Ripple and noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 uf and capacitor of 47uf.
3.Line regulation is measured from low line to high line at rated load.
3.Line regulation is measured from low line to high line at rated load.
3.Line regulation is measured from low line to high line at rated load.
4.Loadregulation is measured from 10% to 100% ratedload.
4.Loadregulation is measured from 10% to 100% ratedload.
4.Loadregulation is measured from 10% to 100% ratedload.
File name:NID30-SPEC2014-11-28
File name:NID30-SPEC2014-11-28
File name:NID30-SPEC2014-11-28