NFM-10-3.3 MEANWELL AC-DC Single output Medical Open frame power supply, Output 3.3VDC / 2.5A, PCB mount, 2x.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NFM-10-3.3 MEANWELL AC-DC Single output Medical Open frame power supply, Output 3.3VDC / 2.5A, PCB mount, 2x..

NFM-10-3.3

MEANWELL

Available Ship on today

AC-DC Single output Medical Open frame power supply, Output 3.3VDC / 2.5A, PCB mount, 2xMOPP

More details


PM,NFM,IRM > NFM

* Brand new product in its original packaging covered by the warranties and certifications provided by MEANWELL

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article: MFM-10-3.3 MFM-10-3.3

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



1 0 W O u t p u t S w i t c h i n g P o w e r S u p p l y N F M - 1 0 s e r i e s 1 0 W O u t p u t S w i t c h i n g P o w e r S u p p l y N F M - 1 0 s e r i e s
1 0 W O u t p u t S w i t c h i n g P o w e r S u p p l y N F M - 1 0 s e r i e sSPECIFICATION SPECIFICATION
SPECIFICATION MODEL MODEL
MODELNFM-10-3.3 NFM-10-3.3
NFM-10-3.3












NFM-10-5 NFM-10-12 NFM-10-15 NFM-10-24 NFM-10-5 NFM-10-12 NFM-10-15 NFM-10-24
NFM-10-5 NFM-10-12 NFM-10-15 NFM-10-24
THE DC VOLTAGE THE DC VOLTAGE
THE DC VOLTAGE 3.3V5V 3.3V5V
3.3V5V 12V 12V
12V 15V 15V
15V 24V 24V
24V RATED CURRENT RATED CURRENT
RATED CURRENT 2.5A2A 2.5A2A
2.5A2A 0.85 A 0.85 A
0.85 A 0.67A0.42A 0.67A0.42A
0.67A0.42A CURRENT RANGE RATED POWER CURRENT RANGE RATED POWER
CURRENT RANGE RATED POWER 0 ~ 2.5 a 0 ~ 2.5 a
0 ~ 2.5 a 8.25 W 8.25 W
8.25 W 0 ~ 2A 0 ~ 2A
0 ~ 2A 10W 10W
10W 0 ~ 0.85A0 ~ 0.67A0 ~ 0.42 A 0 ~ 0.85A0 ~ 0.67A0 ~ 0.42 A
0 ~ 0.85A0 ~ 0.67A0 ~ 0.42 A 10.2 W 10.05 W 10.08 W 10.2 W 10.05 W 10.08 W
10.2 W 10.05 W 10.08 W RIPPLE & NOISE (max.) Note.2150mVp-p RIPPLE & NOISE (max.) Note.2150mVp-p
RIPPLE & NOISE (max.) Note.2150mVp-p 150mVp-p 150mVp-p
150mVp-p 150mVp-p150mVp-p240mVp-p 150mVp-p150mVp-p240mVp-p
150mVp-p150mVp-p240mVp-p OUTPUT VOLTAGE ADJ. RANGE of OUTPUT VOLTAGE ADJ. RANGE of
OUTPUT VOLTAGE ADJ. RANGE of 3 ~ 3.63 V 3 ~ 3.63 V
3 ~ 3.63 V 4.5 ~ 5.5 V 4.5 ~ 5.5 V
4.5 ~ 5.5 V 10.8 ~ 13.2V13.5 ~ 16.5V21.6 ~ 26.4 V 10.8 ~ 13.2V13.5 ~ 16.5V21.6 ~ 26.4 V
10.8 ~ 13.2V13.5 ~ 16.5V21.6 ~ 26.4 V VOLTAGE TOLERANCE Note.32.0% VOLTAGE TOLERANCE Note.32.0%
VOLTAGE TOLERANCE Note.32.0% 2.0% 2.0%
2.0% 1.0% 1.0%
1.0% 1.0%1.0% 1.0%1.0%
1.0%1.0% LINE REGULATION LOAD REGULATION LINE REGULATION LOAD REGULATION
LINE REGULATION LOAD REGULATION 1.0% 1.0%
1.0% 1.0% 1.0%
1.0% 1.0% 1.0%
1.0% 1.0% 1.0%
1.0% 0.5% 0.5%
0.5% 0.5% 0.5%
0.5% 0.5% 0.5%
0.5% 0.5% 0.5%
0.5% 0.5% 0.5%
0.5% 0.5% 0.5%
0.5% SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE
SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE FREQUENCY RANGE
FREQUENCY RANGE 1800ms, 20ms/230VAC 1800ms, 20ms/115VAC at full load 1800ms, 20ms/230VAC 1800ms, 20ms/115VAC at full load
1800ms, 20ms/230VAC 1800ms, 20ms/115VAC at full load 100ms/230VAC24ms/115VAC at full load 100ms/230VAC24ms/115VAC at full load
100ms/230VAC24ms/115VAC at full load 85 ~ 264VAC120 ~ 370VDC 85 ~ 264VAC120 ~ 370VDC
85 ~ 264VAC120 ~ 370VDC 47 ~ 440Hz 47 ~ 440Hz
47 ~ 440HzINPUT INPUT
INPUT EFFICIENCY (Typ.) EFFICIENCY (Typ.)
EFFICIENCY (Typ.) 66% 66%
66% 74% 74%
74% 78% 78%
78% 79% 79%
79% 79% 79%
79% AC CURRENT (Typ.) AC CURRENT (Typ.)
AC CURRENT (Typ.) INRUSH CURRENT (Typ.) The LEAKAGE CURRENTNote.6 INRUSH CURRENT (Typ.) The LEAKAGE CURRENTNote.6
INRUSH CURRENT (Typ.) The LEAKAGE CURRENTNote.6OVERLOAD The OVERHEAD of
The OVERHEAD of 0.25/115VAC0.15A/230VAC 0.25/115VAC0.15A/230VAC
0.25/115VAC0.15A/230VAC COLD start 25A/115VAC 45A/230VAC Touch current < 80 A/264VAC COLD start 25A/115VAC 45A/230VAC Touch current < 80 A/264VAC
COLD start 25A/115VAC 45A/230VAC Touch current < 80 A/264VAC Above 105% rated output power Above 105% rated output power
Above 105% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.95 V 3.8 ~ 4.95 V
3.8 ~ 4.95 V 5.75 ~ 6.75 V 5.75 ~ 6.75 V
5.75 ~ 6.75 V 13.8 ~ 16.2 V 13.8 ~ 16.2 V
13.8 ~ 16.2 V 17.25 ~ 20.25 V 17.25 ~ 20.25 V
17.25 ~ 20.25 V 27.6 ~ 32.4 V 27.6 ~ 32.4 V
27.6 ~ 32.4 V PROTECTION PROTECTION
PROTECTION OVER VOLTAGE OVER VOLTAGE
OVER VOLTAGE Protection type : Shut off o/p voltage, clamping by zener diode Protection type : Shut off o/p voltage, clamping by zener diode
Protection type : Shut off o/p voltage, clamping by zener diode Tj 140 typically (U1) detect on main control IC Tj 140 typically (U1) detect on main control IC
Tj 140 typically (U1) detect on main control IC MOST of TEMPERATURENote.5 Protection type : Shut down o/p voltage, recovers automatically after temperature goes down MOST of TEMPERATURENote.5 Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
MOST of TEMPERATURENote.5 Protection type : Shut down o/p voltage, recovers automatically after temperature goes downENVIRONMENT ENVIRONMENT
ENVIRONMENT WORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION WORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
WORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY STANDARDS
SAFETY STANDARDS -20 ~ +70 (Refer to "Reduction Curve") -20 ~ +70 (Refer to "Reduction Curve")
-20 ~ +70 (Refer to "Reduction Curve") 20 ~ 90% RH non-condensing 20 ~ 90% RH non-condensing
20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH -40 ~ +85, 10 ~ 95% RH
-40 ~ +85, 10 ~ 95% RH 0.03%/ (0 ~ 50) 0.03%/ (0 ~ 50)
0.03%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes 10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes
10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes ANSI/AAMI ES60601-1,TUV EN60601-1, IEC60601-1 approved ANSI/AAMI ES60601-1,TUV EN60601-1, IEC60601-1 approved
ANSI/AAMI ES60601-1,TUV EN60601-1, IEC60601-1 approved ISOLATION LEVELPrimary-Secondary: 2xMOPP ISOLATION LEVELPrimary-Secondary: 2xMOPP
ISOLATION LEVELPrimary-Secondary: 2xMOPP SAFETY AND EMC SAFETY AND EMC
SAFETY AND EMC (Note 4) (Note 4)
(Note 4)OTHER OTHER
OTHER VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION
VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION EMC IMMUNITY MTBF DIMENSION
EMC IMMUNITY MTBF DIMENSION PACKAGING PACKAGING
PACKAGING I/P-O/P:4KVAC I/P-O/P:4KVAC
I/P-O/P:4KVAC I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55011(CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN55011(CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN55011(CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A 723.2 Khrs min.MIL-HDBK-217F (25) 723.2 Khrs min.MIL-HDBK-217F (25)
723.2 Khrs min.MIL-HDBK-217F (25) 65*45*22 mm (L*W*H) 65*45*22 mm (L*W*H)
65*45*22 mm (L*W*H) 0.045 Kg; 120pcs/6.4 Kg/0.97 CUFT 0.045 Kg; 120pcs/6.4 Kg/0.97 CUFT
0.045 Kg; 120pcs/6.4 Kg/0.97 CUFTNOTE NOTE
NOTE







File name:NFM-10-SPEC2014-12-09 File name:NFM-10-SPEC2014-12-09
File name:NFM-10-SPEC2014-12-09

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.