PM-10-3.3 MEANWELL AC-DC Single output Medical Encapsulated power supply, Output 3.3VDC / 2.5A, PCB mount, 2.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PM-10-3.3 MEANWELL AC-DC Single output Medical Encapsulated power supply, Output 3.3VDC / 2.5A, PCB mount, 2..

PM-10-3.3

MEANWELL

Available Ship on today

AC-DC Single output Medical Encapsulated power supply, Output 3.3VDC / 2.5A, PCB mount, 2xMOPP

More details


PM,NFM,IRM > PM

* Brand new product in its original packaging covered by the warranties and certifications provided by MEANWELL

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article: MPM-10-3.3 MPM-10-3.3

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



10W Output Switching Power supply PM-10series 10W Output Switching Power supply PM-10series
10W Output Switching Power supply PM-10series SPECIFICATION SPECIFICATION
SPECIFICATION MODEL MODEL
MODELPM-10-3.3 PM-10-3.3
PM-10-3.3 Features : Features :
Features : Universal AC input / Full range Universal AC input / Full range
Universal AC input / Full range Protections: short circuit / Overload/ Over voltage Protections: short circuit / Overload/ Over voltage
Protections: short circuit / Overload/ Over voltage Ultra-mini size, light weight Ultra-mini size, light weight
Ultra-mini size, light weight Cooling by free air convection Cooling by free air convection
Cooling by free air convection Insulation class Insulation class
Insulation class Medical safety approved (2 x MOPPbetweenprimaryto secondary) Medical safety approved (2 x MOPPbetweenprimaryto secondary)
Medical safety approved (2 x MOPPbetweenprimaryto secondary) Do not load powerconsumptione0.5w Do not load powerconsumptione0.5w
Do not load powerconsumptione0.5w 100% full load burn-in test 100% full load burn-in test
100% full load burn-in test Fixed switchingfrequencyat 67KHz Fixed switchingfrequencyat 67KHz
Fixed switchingfrequencyat 67KHz High reliability High reliability
High reliability Suitable for BF application with appropriate systemconsideration Suitable for BF application with appropriate systemconsideration
Suitable for BF application with appropriate systemconsideration 3 years warranty 3 years warranty
3 years warrantyPM-10-5 PM-10-12-10-15-10-24 PM-10-5 PM-10-12-10-15-10-24
PM-10-5 PM-10-12-10-15-10-24
THE DC VOLTAGE THE DC VOLTAGE
THE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RATED CURRENT CURRENT RANGE RATED POWER
RATED CURRENT CURRENT RANGE RATED POWER 3.3 V 3.3 V
3.3 V 2.5 to 2.5 to
2.5 to 0 ~ 2.5 a 0 ~ 2.5 a
0 ~ 2.5 a 8.25 W 8.25 W
8.25 W 5V 5V
5V 2A 2A
2A 0 ~ 2A 0 ~ 2A
0 ~ 2A 10W 10W
10W 12V 15V 24V 12V 15V 24V
12V 15V 24V 0.85A0.67A0.42A 0.85A0.67A0.42A
0.85A0.67A0.42A 0 ~ 0.85A0 ~ 0.67A0 ~ 0.42 A 0 ~ 0.85A0 ~ 0.67A0 ~ 0.42 A
0 ~ 0.85A0 ~ 0.67A0 ~ 0.42 A 10.2 W 10.05 W 10.08 W 10.2 W 10.05 W 10.08 W
10.2 W 10.05 W 10.08 WOUTPUT OUTPUT
OUTPUT RIPPLE & NOISE (max.) Note.2150mVp-p RIPPLE & NOISE (max.) Note.2150mVp-p
RIPPLE & NOISE (max.) Note.2150mVp-p VOLTAGE TOLERANCE Note.33.0% VOLTAGE TOLERANCE Note.33.0%
VOLTAGE TOLERANCE Note.33.0% 150mVp-p 150mVp-p
150mVp-p 2.0% 2.0%
2.0% 150mVp-p150mVp-p240mVp-p 150mVp-p150mVp-p240mVp-p
150mVp-p150mVp-p240mVp-p 2.0%2.0%2.0% 2.0%2.0%2.0%
2.0%2.0%2.0% LINE REGULATION LOAD REGULATION LINE REGULATION LOAD REGULATION
LINE REGULATION LOAD REGULATION 1.0% 1.0%
1.0% 1.0% 1.0%
1.0% 1.0% 1.0%
1.0% 1.0% 1.0%
1.0% 0.5% 0.5%
0.5% 1.0% 1.0%
1.0% 0.5% 0.5%
0.5% 1.0% 1.0%
1.0% 0.5% 0.5%
0.5% 0.5% 0.5%
0.5% SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE
SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE FREQUENCY RANGE
FREQUENCY RANGE 1800ms, 20ms/230VAC 1800ms, 20ms/115VAC at full load 1800ms, 20ms/230VAC 1800ms, 20ms/115VAC at full load
1800ms, 20ms/230VAC 1800ms, 20ms/115VAC at full load 100ms/230VAC24ms/115VAC at full load 100ms/230VAC24ms/115VAC at full load
100ms/230VAC24ms/115VAC at full load 85 ~ 264VAC120 ~ 370VDC 85 ~ 264VAC120 ~ 370VDC
85 ~ 264VAC120 ~ 370VDC 47 ~ 440Hz 47 ~ 440Hz
47 ~ 440HzINPUT INPUT
INPUT EFFICIENCY (Typ.) EFFICIENCY (Typ.)
EFFICIENCY (Typ.) 66% 66%
66% 74% 74%
74% 78% 78%
78% 79% 79%
79% 79% 79%
79% AC CURRENT (Typ.) AC CURRENT (Typ.)
AC CURRENT (Typ.) INRUSH CURRENT (Typ.) INRUSH CURRENT (Typ.)
INRUSH CURRENT (Typ.) 0.25/115VAC0.15A/230VAC 0.25/115VAC0.15A/230VAC
0.25/115VAC0.15A/230VAC COLD START 25A/115VAC 45A/230VAC COLD START 25A/115VAC 45A/230VAC
COLD START 25A/115VAC 45A/230VAC LEAKAGE CURRENT Note.5 Touch current < 80 a/264VAC Above 105% rated output power LEAKAGE CURRENT Note.5 Touch current < 80 a/264VAC Above 105% rated output power
LEAKAGE CURRENT Note.5 Touch current < 80 a/264VAC Above 105% rated output power The OVERHEAD of The OVERHEAD of
The OVERHEAD of Protection type : Hiccup mode, recovers automatically after fault condition is removed Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION PROTECTION
PROTECTION 3.8 ~ 4.95 V 3.8 ~ 4.95 V
3.8 ~ 4.95 V 5.75 ~ 6.75 V 5.75 ~ 6.75 V
5.75 ~ 6.75 V 13.8 ~ 16.2 V 13.8 ~ 16.2 V
13.8 ~ 16.2 V 17.25 ~ 20.25 V 17.25 ~ 20.25 V
17.25 ~ 20.25 V 27.6 ~ 32.4 V 27.6 ~ 32.4 V
27.6 ~ 32.4 V ENVIRONMENT ENVIRONMENT
ENVIRONMENT OVER VOLTAGE OVER VOLTAGE
OVER VOLTAGEWORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION WORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
WORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY STANDARDS
SAFETY STANDARDS Protection type : Shut off o/p voltage, clamping by zener diode Protection type : Shut off o/p voltage, clamping by zener diode
Protection type : Shut off o/p voltage, clamping by zener diode -20 ~ +70c (Refer to "Reduction Curve") -20 ~ +70c (Refer to "Reduction Curve")
-20 ~ +70c (Refer to "Reduction Curve") 20 ~ 90% RH non-condensing 20 ~ 90% RH non-condensing
20 ~ 90% RH non-condensing -40 ~ +85℃, 10 ~ 95% RH -40 ~ +85℃, 10 ~ 95% RH
-40 ~ +85℃, 10 ~ 95% RH 0.03%/c (0 ~ 50 ° c) 0.03%/c (0 ~ 50 ° c)
0.03%/c (0 ~ 50 ° c) 10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes 10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes
10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved
ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved ISOLATION LEVELPrimary-Secondary: 2xMOPP ISOLATION LEVELPrimary-Secondary: 2xMOPP
ISOLATION LEVELPrimary-Secondary: 2xMOPP SAFETY AND EMC SAFETY AND EMC
SAFETY AND EMC (Note 4) (Note 4)
(Note 4)OTHER OTHER
OTHER VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION
VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION EMC IMMUNITY MTBF DIMENSION
EMC IMMUNITY MTBF DIMENSION PACKAGING PACKAGING
PACKAGING I/P-O/P:4KVAC I/P-O/P:4KVAC
I/P-O/P:4KVAC I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A 723.2 Khrs min.MIL-HDBK-217F (25c) 723.2 Khrs min.MIL-HDBK-217F (25c)
723.2 Khrs min.MIL-HDBK-217F (25c) 70*50*22.7 mm (L*W*H) 70*50*22.7 mm (L*W*H)
70*50*22.7 mm (L*W*H) 0.105 Kg; 120pcs/13.6 Kg/0.97 CUFT 0.105 Kg; 120pcs/13.6 Kg/0.97 CUFT
0.105 Kg; 120pcs/13.6 Kg/0.97 CUFTNOTE NOTE
NOTE 1. All parameters NOT specially mentioned are measured at 230vac input, ratedload and 25 ° c ambient temperature. 1. All parameters NOT specially mentioned are measured at 230vac input, ratedload and 25 ° c ambient temperature.
1. All parameters NOT specially mentioned are measured at 230vac input, ratedload and 25 ° c ambient temperature. 2. Curly and noiseare measured at 20 mhz of bandwidth by usinga 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 2. Curly and noiseare measured at 20 mhz of bandwidth by usinga 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
2. Curly and noiseare measured at 20 mhz of bandwidth by usinga 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. EMC directives.
EMC directives. 5. Touch currentwas measured from the main entrance to the DC output. 5. Touch currentwas measured from the main entrance to the DC output.
5. Touch currentwas measured from the main entrance to the DC output.File name:PM-10-SPEC2014-12-09 File name:PM-10-SPEC2014-12-09
File name:PM-10-SPEC2014-12-09

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.