70 W Single Output switching Power supply
70 W Single Output switching Power supply
70W Single Output Switching Power SupplyFeatures :
Features :
Features :
HSG-70series
HSG-70series
HSG-70series
UniversalAC input / Full range(up to 305VAC)
UniversalAC input / Full range(up to 305VAC)
UniversalAC input / Full range(up to 305VAC)
Protections:short circuit/overload/Over voltage/Over temperature
Protections:short circuit/overload/Over voltage/Over temperature
Protections:short circuit/overload/Over voltage/Over temperature
Built-in active PFC function
Built-in active PFC function
Built-in active PFC function
High efficiency, up to 90%
High efficiency, up to 90%
High efficiency, up to 90%
Cooling by free air convection
Cooling by free air convection
Cooling by free air convection
IP65 design for indoor and outdoorinstallations
IP65 design for indoor and outdoorinstallations
IP65 design for indoor and outdoorinstallations
Small and compact size
Small and compact size
Small and compact size
High reliability,low cost
High reliability,low cost
High reliability,low cost
Suitable for LED lighting and movingsign applications
Suitable for LED lighting and movingsign applications
Suitable for LED lighting and movingsign applications
3 years warranty
3 years warranty
3 years warrantySPECIFICATION
SPECIFICATION
SPECIFICATION
MODEL
MODEL
MODEL
HSG-70-12
HSG-70-12
HSG-70-12
HSG-70-18 HSG-70-24 HSG-70-36
HSG-70-18 HSG-70-24 HSG-70-36
HSG-70-18 HSG-70-24 HSG-70-36
IP65
IP65
IP65HSG-70-48
HSG-70-48
HSG-70-48
THE DC VOLTAGE
THE DC VOLTAGE
THE DC VOLTAGE
12V
12V
12V
18V
18V
18V
24V
24V
24V
36V
36V
36V
48V
48V
48V
CONSTANT CURRENT REGION Note.57.7 ~ 12V
CONSTANT CURRENT REGION Note.57.7 ~ 12V
CONSTANT CURRENT REGION Note.57.7 ~ 12V
11.3 ~ 18V
11.3 ~ 18V
11.3 ~ 18V
15.5 ~ 24V
15.5 ~ 24V
15.5 ~ 24V
22.1 ~ 36V
22.1 ~ 36V
22.1 ~ 36V
29.3 ~ 48V
29.3 ~ 48V
29.3 ~ 48V
NOMINAL CURRENT NOMINAL POWER
NOMINAL CURRENT NOMINAL POWER
NOMINAL CURRENT NOMINAL POWER
5.0 A
5.0 A
5.0 A
60W
60W
60W
4.0A3.0A2.0A
4.0A3.0A2.0A
4.0A3.0A2.0A
72W72W72W
72W72W72W
72W72W72W
1.5 A
1.5 A
1.5 A
72W
72W
72WCURRENT ADJ. RANGE of
CURRENT ADJ. RANGE of
CURRENT ADJ. RANGE of
Can be adjusted by internal potentiometer
Can be adjusted by internal potentiometer
Can be adjusted by the inner potentiometerOUTPUT
OUTPUT
OUTPUT
3 ~ 5A
3 ~ 5A
3 ~ 5A
RIPPLE & NOISE (max.) Note.2150mVp-p
RIPPLE & NOISE (max.) Note.2150mVp-p
RIPPLE & NOISE (max.) Note.2150mVp-p
2.4 ~ 4A1.8 ~ 3A1.2 ~ 2A
2.4 ~ 4A1.8 ~ 3A1.2 ~ 2A
2.4 ~ 4A1.8 ~ 3A1.2 ~ 2A
200mVp-p200mVp-p200mVp-p
200mVp-p200mVp-p200mVp-p
200mVp-p200mVp-p200mVp-p
0.9 ~ 1.5 to
0.9 ~ 1.5 to
0.9 ~ 1.5 to
200mVp-p
200mVp-p
200mVp-p
VOLTAGE TOLERANCE Note.32.5%
VOLTAGE TOLERANCE Note.32.5%
VOLTAGE TOLERANCE Note.32.5%
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION LOAD REGULATION
LINE REGULATION LOAD REGULATION
LINE REGULATION LOAD REGULATION
0.5%
0.5%
0.5%
2.0%
2.0%
2.0%
0.5%
0.5%
0.5%
1.5%
1.5%
1.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME Note.72000ms,80ms / 115VAC 500ms,80ms / 230VAC at full load
SETUP, RISE TIME Note.72000ms,80ms / 115VAC 500ms,80ms / 230VAC at full load
SETUP, RISE TIME Note.72000ms,80ms / 115VAC 500ms,80ms / 230VAC at full load
KEEP THE TIME OF
KEEP THE TIME OF
KEEP THE TIME OF
16ms at full load230VAC/115VAC
16ms at full load230VAC/115VAC
16ms at full load230VAC/115VAC
VOLTAGE RANGENote.490 ~ 305VAC127~431VDC
VOLTAGE RANGENote.490 ~ 305VAC127~431VDC
VOLTAGE RANGENote.490 ~ 305VAC127~431VDC
FREQUENCY RANGE POWER FACTOR(Typ.)
FREQUENCY RANGE POWER FACTOR(Typ.)
FREQUENCY RANGE POWER FACTOR(Typ.)
TOTAL HARMONIC DISTORTION
TOTAL HARMONIC DISTORTION
TOTAL HARMONIC DISTORTION
47 ~ 63Hz
47 ~ 63Hz
47 ~ 63Hz
PF0.96/115VAC, PF0.96/230VAC,PF>0.92/277VAC at full load(please refer to "Power Factor characteristic curve"), THD< 20% when output loading65% at 115VAC/230VAC input and output loading75% at 277VAC input
PF0.96/115VAC, PF0.96/230VAC,PF>0.92/277VAC at full load(please refer to "Power Factor characteristic curve"), THD< 20% when output loading65% at 115VAC/230VAC input and output loading75% at 277VAC input
PF0.96/115VAC, PF0.96/230VAC,PF>0.92/277VAC at full load(please refer to "Power Factor characteristic curve"), THD< 20% when output loading65% at 115VAC/230VAC input and output loading75% at 277VAC input
INPUT
INPUT
INPUT
EFFICIENCY(Typ.)
EFFICIENCY(Typ.)
EFFICIENCY(Typ.)
88%
88%
88%
89%89%90% 90%
89%89%90% 90%
89%89%90% 90%
AC POWER
AC POWER
AC POWER
INRUSH CURRENT(Typ.) MAX. No. of the systems of power in the 16TH
INRUSH CURRENT(Typ.) MAX. No. of the systems of power in the 16TH
INRUSH CURRENT(Typ.) MAX. No. of the systems of power in the 16TH
CIRCUIT BREAKER
CIRCUIT BREAKER
CIRCUIT BREAKER
The LEAKAGE CURRENT of the Note.5
The LEAKAGE CURRENT of the Note.5
The LEAKAGE CURRENT of the Note.5
0.85 A/115VAC 0.425 A/230VAC0.4A/277VAC
0.85 A/115VAC 0.425 A/230VAC0.4A/277VAC
0.85 A/115VAC 0.425 A/230VAC0.4A/277VAC
COLD start 55A(twidth=340 measured at 50% Ipeak) at 230VAC
COLD start 55A(twidth=340 measured at 50% Ipeak) at 230VAC
COLD start 55A(twidth=340 measured at 50% Ipeak) at 230VAC6 units (circuit breaker type B) / 11 units (circuit breaker type C) 230VAC
6 units (circuit breaker type B) / 11 units (circuit breaker type C) 230VAC
6 units (circuit breaker type B) / 11 units (circuit breaker type C) at 230vac<0.75 mA / 277VAC
<0.75 mA / 277VAC
<0.75 mA / 277VAC
95 ~ 108%
95 ~ 108%
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed.
SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed.
SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed.PROTECTION
PROTECTION
PROTECTIONOVER VOLTAGE
OVER VOLTAGE
OVER VOLTAGE
14 ~ 17V
14 ~ 17V
14 ~ 17V
21 ~ 25V 28 ~ 34V41 ~ 48V 54 ~ 63V
21 ~ 25V 28 ~ 34V41 ~ 48V 54 ~ 63V
21 ~ 25V 28 ~ 34V41 ~ 48V 54 ~ 63VENVIRONMENT
ENVIRONMENT
ENVIRONMENT
SAFETY AND EMC
SAFETY AND EMC
SECURITY AND EMCOTHERS
OTHER
OTHERSOVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY
THE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY
THE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY
STORAGE TEMP., THE HUMIDITY TEMP. COEFFICIENT VIBRATION
STORAGE TEMP., THE HUMIDITY TEMP. COEFFICIENT VIBRATION
STORAGE TEMP., THE HUMIDITY TEMP. COEFFICIENT VIBRATION
SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION
SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION
SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION
EMC IMMUNITY MTBF DIMENSION
EMC IMMUNITY MTBF DIMENSION
EMC IMMUNITY MTBF DIMENSION
PACKAGING
PACKAGING
PACKAGING
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
-40 ~ +70(Refer to "Reduction Curve")
-40 ~ +70(Refer to "Reduction Curve")
-40 ~ +70(Refer to "Reduction Curve")
20 ~ 95% RH non-condensing
20 ~ 95% RH non-condensing
20 ~ 95% RH non-condensing
-40 ~ +80, 10 ~ 95% RH
-40 ~ +80, 10 ~ 95% RH
-40 ~ +80, 10 ~ 95% RH
0.03%/ (0 ~ 50)
0.03%/ (0 ~ 50)
0.03%/ (0 ~ 50)
10 ~ 500 hz, 5 G, 10 min./1cycle, period for 60 min. each along X, y, Z axes
10 ~ 500 hz, 5 G, 10 min./1cycle, period for 60 min. each along X, y, Z axes
10 ~ 500 hz, 5 G, 10 min./1cycle, period for 60 min. each along X, y, Z axes
GB19510.14, GB19510.1, IP65 approved; design refer to TUV EN61347-1, EN61347-2-13, UL8750
GB19510.14, GB19510.1, IP65 approved; design refer to TUV EN61347-1, EN61347-2-13, UL8750
GB19510.14, GB19510.1, IP65 approved; design refer to TUV EN61347-1, EN61347-2-13, UL8750
I/P-O/P:3.75 KVAC I/P-FG:2KVAC O/P-FG:0.5 KVAC
I/P-O/P:3.75 KVAC I/P-FG:2KVAC O/P-FG:0.5 KVAC
I/P-O/P:3.75 KVAC I/P-FG:2KVAC O/P-FG:0.5 KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25/ 70% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25/ 70% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25/ 70% RH
Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C(65% load);EN61000-3-3
Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C(65% load);EN61000-3-3
Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C(65% load);EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
338.2 Khrs min.MIL-HDBK-217F (25)
338.2 Khrs min.MIL-HDBK-217F (25)
338.2 Khrs min.MIL-HDBK-217F (25)
127.2*90*38.8 mm (L*W*H)
127.2*90*38.8 mm (L*W*H)
127.2*90*38.8 mm (L*W*H)
0.76 Kg;16pcs/ 13.2 Kgs/0.77 CUFT
0.76 Kg;16pcs/ 13.2 Kgs/0.77 CUFT
0.76 Kg;16pcs/ 13.2 Kg/0.77 CUFTNOTE
NOTE
NOTE
1. All the parameters are NOT speciallymentioned are measured at 230vac input, rated load and 25 ° C ambient temperature.
1. All the parameters are NOT speciallymentioned are measured at 230vac input, rated load and 25 ° C ambient temperature.
1. All the parameters are NOT speciallymentioned are measured at 230vac input, rated load and 25 ° C ambient temperature.
2. Curly and noiseare measured at 20 mhz of bandwidth by using a 12" twisted pair-wire terminatedwith a 0.1 uf and 47uf capacitor in parallel.
2. Curly and noiseare measured at 20 mhz of bandwidth by using a 12" twisted pair-wire terminatedwith a 0.1 uf and 47uf capacitor in parallel.
2. Curly and noiseare measured at 20 mhz of bandwidth by using a 12" twisted pair-wire terminatedwith a 0.1 uf and 47uf capacitor in parallel.
3. Tolerance : includes setup tolerance, line regulation and load regulation.
3. Tolerance : includes setup tolerance, line regulation and load regulation.
3. Tolerance : includes setup tolerance, line regulation and load regulation.
4. Deratingmay be necessary underlow input voltage,please checkthe static characteristics for more details.
4. Deratingmay be necessary underlow input voltage,please checkthe static characteristics for more details.
4. Deratingmay be necessary underlow input voltage,please checkthe static characteristics for more details.
5. Constant currentoperation region is within 65% >100%nominal outputvoltage.This is the suitable operation region for LED relatedapplications, but please reconfirm special electricalrequirements for some specific system design.
5. Constant currentoperation region is within 65% >100%nominal outputvoltage.This is the suitable operation region for LED relatedapplications, but please reconfirm special electricalrequirements for some specific system design.
5. Constant currentoperation region is within 65% >100%nominal outputvoltage.This is the suitable operation region for LED relatedapplications, but please reconfirm special electricalrequirements for some specific system design.
6. The supply is considered a component which will be operated in combination with final equipment. SinceEMC the performance will be affectedby the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain.
6. The supply is considered a component which will be operated in combination with final equipment. SinceEMC the performance will be affectedby the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain.
6. The supply is considered a component which will be operated in combination with final equipment. SinceEMC the performance will be affectedby the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain.
7. Lengthof setting time is measured at cold first start.Turn on/OFF the supply can lead to the increase of the setup time.
7. Lengthof setting time is measured at cold first start.Turn on/OFF the supply can lead to the increase of the setup time.
7. Lengthof setting time is measured at cold first start.Turn on/OFF the supply can lead to the increase of the setup time.
a.To comply with the requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
a.To comply with the requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
a.To comply with the requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the electrical grid.
connected to the electrical grid.
connected to the electrical grid.File name:HSG-70-SPEC2015-11-02
File name:HSG-70-SPEC2015-11-02
File name:HSG-70-SPEC2015-11-02