24 - 50W AC-DC Single Output and Medical Type DesktopM E S 5 0 s e r i e s
24 - 50W AC-DC Single Output and Medical Type DesktopM E S 5 0 s e r i e s
24 - 50W AC-DC Single Output and Medical Type DesktopM E S 5 0 s e r i e sFeatures :
Features :
Features :
EUniversal AC input / Full range
EUniversal AC input / Full range
EUniversal AC input / Full range
E3 pole AC inlet IEC320-C14
E3 pole AC inlet IEC320-C14
E3 pole AC inlet IEC320-C14
ELow leakage current <230gA
ELow leakage current <230gA
ELow leakage current <230gA
EClass I power ( with earthpin)
EClass I power ( with earthpin)
EClass I power ( with earthpin)
EFull output 3~48V safety approval
EFull output 3~48V safety approval
EFull output 3~48V safety approval
EProtections: short circuit / Overload / Over voltage / Over temperature.
EProtections: short circuit / Overload / Over voltage / Over temperature.
EProtections: short circuit / Overload / Over voltage / Over temperature.
EFully closed the plastic case
EFully closed the plastic case
EFully closed the plastic case
EMedical safety approved (MOPP level)
EMedical safety approved (MOPP level)
EMedical safety approved (MOPP level)
EFix switching frequency and regulation
EFix switching frequency and regulation
EFix switching frequency and regulation
ETopology: Top switch circuit
ETopology: Top switch circuit
ETopology: Top switch circuit
TRAVELED power indicator
TRAVELED power indicator
TRAVELED power indicator
EApprovals: UL / CUL / TUV / CB / CE
EApprovals: UL / CUL / TUV / CB / CE
EApprovals: UL / CUL / TUV / CB / CE
E2 year warranty
E2 year warranty
E2 years warrantySPECIFICATION
SPECIFICATION
SPECIFICATION
ORDER NO.
ORDER NO.
ORDER NO.
MES50A-0R1BMES50A-1R1BMES50A-1-1R1B MES50A-2P1J MES50A-3P1J MES50A-4P1J MES50A-5P1J MES50A-6P1J MES50A-7P1J MES50A-8P1J
MES50A-0R1BMES50A-1R1BMES50A-1-1R1B MES50A-2P1J MES50A-3P1J MES50A-4P1J MES50A-5P1J MES50A-6P1J MES50A-7P1J MES50A-8P1J
MES50A-0R1BMES50A-1R1BMES50A-1-1R1B MES50A-2P1J MES50A-3P1J MES50A-4P1J MES50A-5P1J MES50A-6P1J MES50A-7P1J MES50A-8P1J
SECURITY MODEL NO.
SECURITY MODEL NO.
SECURITY MODEL NO.
MES50A-0 MES50A-1 MES50A-1-1 MES50A-2 MES50A-3 MES50A-4
MES50A-0 MES50A-1 MES50A-1-1 MES50A-2 MES50A-3 MES50A-4
MES50A-0 MES50A-1 MES50A-1-1 MES50A-2 MES50A-3 MES50A-4
MES50A-5 MES50A-6 MES50A-7 MES50A-8
MES50A-5 MES50A-6 MES50A-7 MES50A-8
MES50A-5 MES50A-6 MES50A-7 MES50A-8
DC VOLTAGENote.23.3V5V 7.5V9V 12V 15V
DC VOLTAGENote.23.3V5V 7.5V9V 12V 15V
DC VOLTAGENote.23.3V5V 7.5V9V 12V 15V
18V, 24V 28V 48V
18V, 24V 28V 48V
18V, 24V 28V 48V
RATED CURRENT CURRENT RANGE RATED POWER
RATED CURRENT CURRENT RANGE RATED POWER
RATED CURRENT CURRENT RANGE RATED POWER
7.5A7.5A5.33A5.0A4.16A3.33A2.77A2.08A1.78A1.04A
7.5A7.5A5.33A5.0A4.16A3.33A2.77A2.08A1.78A1.04A
7.5A7.5A5.33A5.0A4.16A3.33A2.77A2.08A1.78A1.04A
0 - 7.5A0 - 7.5A0 - 5.33A0 - 5.0A0 - 4.16A0 - 3.33A0 - 2.77A0 - 2.08A0 - 1.78A0 - 1.04 A
0 - 7.5A0 - 7.5A0 - 5.33A0 - 5.0A0 - 4.16A0 - 3.33A0 - 2.77A0 - 2.08A0 - 1.78A0 - 1.04 A
0 - 7.5A0 - 7.5A0 - 5.33A0 - 5.0A0 - 4.16A0 - 3.33A0 - 2.77A0 - 2.08A0 - 1.78A0 - 1.04 A
24.75 37.5 W W 40W45W50W50W50W50W50W50W
24.75 37.5 W W 40W45W50W50W50W50W50W50W
24.75 37.5 W W 40W45W50W50W50W50W50W50W
OUTPUT
OUTPUT
OUTPUT
RIPPLE & NOISE (max.) Note.350mVp-p50mVp-p75mVp-p90mVp-p100mVp-p100mVp-p150mVp-p150mVp-p150mVp-p200mVp-p
RIPPLE & NOISE (max.) Note.350mVp-p50mVp-p75mVp-p90mVp-p100mVp-p100mVp-p150mVp-p150mVp-p150mVp-p200mVp-p
RIPPLE & NOISE (max.) Note.350mVp-p50mVp-p75mVp-p90mVp-p100mVp-p100mVp-p150mVp-p150mVp-p150mVp-p200mVp-p
VOLTAGE ADJ. Fixed RANGE
VOLTAGE ADJ. Fixed RANGE
VOLTAGE ADJ. Fixed RANGE
VOLTAGE TOLERANCE Note.410%
VOLTAGE TOLERANCE Note.410%
VOLTAGE TOLERANCE Note.410%
6.0%
6.0%
6.0%
5.0%
5.0%
5.0%
5.0%
5.0%
5.0%
3.0% 3.0%
3.0% 3.0%
3.0% 3.0%
3.0%
3.0%
3.0%
2.0% 2.0% 2.0%
2.0% 2.0% 2.0%
2.0% 2.0% 2.0%
LINE REGULATIONNote.51.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
LINE REGULATIONNote.51.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
LINE REGULATIONNote.51.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
LOAD REGULATIONNote.610%
LOAD REGULATIONNote.610%
LOAD REGULATIONNote.610%
6.0%
6.0%
6.0%
5.0%
5.0%
5.0%
5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
2.0% 2.0% 2.0%
2.0% 2.0% 2.0%
2.0% 2.0% 2.0%
INPUT
INPUT
INPUT
The INSTALLATION program, PLACE, TIME VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.)
The INSTALLATION program, PLACE, TIME VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.)
The INSTALLATION program, PLACE, TIME VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.)
AC POWER
AC POWER
AC POWER
Input CURRENT (max.)
Input CURRENT (max.)
Input CURRENT (max.)
300 ms, 50 ms, 16msat full load
300 ms, 50 ms, 16msat full load
300 ms, 50 ms, 16msat full load
90 - 264VAC135-370VDC
90 - 264VAC135-370VDC
90 - 264VAC135-370VDC
47-63Hz
47-63Hz
47-63Hz
60%67%70%72%74%
60%67%70%72%74%
60%67%70%72%74%
1.5 A / 100VAC
1.5 A / 100VAC
1.5 A / 100VAC
90A / 230VAC
90A / 230VAC
90A / 230VAC
75%78%78%80%80%
75%78%78%80%80%
75%78%78%80%80%
The LEAKAGE CURRENT (max.) Note.7 Earth leakage current < 230gA/264VAC , Touch current < 60gA/264VAC
The LEAKAGE CURRENT (max.) Note.7 Earth leakage current < 230gA/264VAC , Touch current < 60gA/264VAC
The LEAKAGE CURRENT (max.) Note.7 Earth leakage current < 230gA/264VAC , Touch current < 60gA/264VACOVERLOAD
The OVERHEAD of
The OVERHEAD of
112 - 250%rated output power
112 - 250%rated output power
112 - 250%rated output power
150 - 350%rated output power
150 - 350%rated output power
150 - 350%rated output power
PROTECTION
PROTECTION
PROTECTIONENVIRONMENT
ENVIRONMENT
ENVIRONMENTSAFETY & EMC
SAFETY AND EMC
SAFETY AND EMC
(Note. 8)
(Note. 8)
(Note. 8)OTHER CONNECTOR
OTHER CONNECTOR
OTHER CONNECTOR
OVER VOLTAGE
OVER VOLTAGE
OVER VOLTAGE
THE OVER TEMPERATURE WORKING TEMP.
THE OVER TEMPERATURE WORKING TEMP.
THE OVER TEMPERATURE WORKING TEMP.
OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION
SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION
SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION
EMC IMMUNITY MTBF DIMENSION PACKING
EMC IMMUNITY MTBF DIMENSION PACKING
EMC IMMUNITY MTBF DIMENSION PACKING
PLUG
PLUG
PLUG
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 - 150% rated output voltage
110 - 150% rated output voltage
110 - 150% rated output voltage
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Tj 135J typically (IC1) detect on main control IC
Tj 135J typically (IC1) detect on main control IC
Tj 135J typically (IC1) detect on main control IC
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
0 - +65J (Refer to the "Reduction Curve")
0 - +65J (Refer to the "Reduction Curve")
0 - +65J (Refer to the "Reduction Curve")
20% - 90% RH non-condensing
20% - 90% RH non-condensing
20% - 90% RH non-condensing
-20 - +85J, 10% - 95% RH
-20 - +85J, 10% - 95% RH
-20 - +85J, 10% - 95% RH
0.03% / J ( 0 - 50J)
0.03% / J ( 0 - 50J)
0.03% / J ( 0 - 50J)
10 - 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes
10 - 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes
10 - 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes
ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved
ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved
ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved
I/P-O/P: 5656VDC , I/P-FG: 2828VDC
I/P-O/P: 5656VDC , I/P-FG: 2828VDC
I/P-O/P: 5656VDC , I/P-FG: 2828VDC
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25J/ 70% RH Compliance to EN55011(CISPR11) class B, EN61000-3-2,3
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25J/ 70% RH Compliance to EN55011(CISPR11) class B, EN61000-3-2,3
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25J/ 70% RH Compliance to EN55011(CISPR11) class B, EN61000-3-2,3
Compliance EN60601-1-2 (EN61000-4-2,3,4,5,6,8,11) light industry level, criteria A
Compliance EN60601-1-2 (EN61000-4-2,3,4,5,6,8,11) light industry level, criteria A
Compliance EN60601-1-2 (EN61000-4-2,3,4,5,6,8,11) light industry level, criteria A
-----
-----
-----
147*75.5*43.2 mm (L*W*H)
147*75.5*43.2 mm (L*W*H)
147*75.5*43.2 mm (L*W*H)
0.55 Kg ;36pcs / 21kg / CARTON
0.55 Kg ;36pcs / 21kg / CARTON
0.55 Kg ;36pcs / 21kg / CARTON
See page 2, Other type available by customer requested
See page 2, Other type available by customer requested
See page 2, Other type available by customer requestedNOTE
NOTE
NOTE
CABLESee page 2, Other type available by customer requested
CABLESee page 2, Other type available by customer requested
CABLESee page 2, Other type available by customer requested
1.All the parameters arespecified at 230 vac input, ratedload,25J 70% relative humidity environment.
1.All the parameters arespecified at 230 vac input, ratedload,25J 70% relative humidity environment.
1.All the parameters arespecified at 230 vac input, ratedload,25J 70% relative humidity environment.
2.DC voltage: The outputvoltage setat point measure by plug terminal & 50% load.
2.DC voltage: The outputvoltage setat point measure by plug terminal & 50% load.
2.DC voltage: The outputvoltage setat point measure by plug terminal & 50% load.
3.Ripple and noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 uf and capacitor of 47uf.
3.Ripple and noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 uf and capacitor of 47uf.
3.Ripple and noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 uf and capacitor of 47uf.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
5.Line regulation is measured from low line to high line at rated load.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% ratedload.
6.Load regulation is measured from 0% to 100% ratedload.
6.Load regulation is measured from 0% to 100% ratedload.
7.Touch currentwas measured from the main entrance to the DC output.
7.Touch currentwas measured from the main entrance to the DC output.
7.Touch currentwas measured from the main entrance to the DC output.
8.The supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
8.The supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
8.The supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
EMC directives.
EMC directives.
File name:MES50A-SPEC2012-09-04
File name:MES50A-SPEC2012-09-04
File name:MES50A-SPEC2012-09-04