LEGRAND 412283 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

412283 LEGRAND LIMIT ENVELOPE T1 25KA 3P+N +SD

Code: 412283

Manufacturer: LEGRAND

Description:

LIMIT ENVELOPE T1 25KA 3P+N +SD
LIMIT SOBRET T1 25KA 3P+N +SD
SPD - high risk level installation - T1+T2 - limp 25 kA/pole - 3P+N right
Surge limiter T1 - very high risk inst. - Iimp 25kA/pole - 3P+N

Categories:

  • Earthing, lightning and surge protection > Surge protection device for power supply systems
  • LEGRAND > MOTOR CIRCUIT BREAKERS

Brand new product in its original packaging covered by the warranties and certifications provided by LEGRAND

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 741,19 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 5 days.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

  • Pack (number of units)1
  • Volume (dm3)2.363
  • Weight (g)1 671.00
Product characteristics
SPDs for high risk level installations
  • SPDs for big installations with external lightning protection (LPS) and for high risk level installations according to EN/IEC 62305 standards
  • SPDs with plug-in modules and status indicators:
    • Green: SPD operational
    • Red: plug-in modules to be replaced
T1 + T2 - Iimp 25 kA/pole
  • Up: 1.5 kV - Uc: 350 V~
  • Earthing systems: TT, TNC, TNS.
  • Recommended MCCB: DPX³ 160 - 80 A
  • 1P+N and 3P+N: L-N and N-PE protection modes (common and differential modes), the N pole being protected by encapsulated spark gaps. Also called 1+1 and 3+1
  • Number of poles : 3P+N
  • Neutral position : Right
  • Itotal (10/350) : 100 kA
  • Remote status monitoring (FS contact) : Yes
  • Number of modules : 8
General characteristics
Class I + II (T1+T2) low voltage SPDs
  • Protection against transient overvoltagess for 230/400 V~ power networks (50/60 Hz).
  • SPDs compliant with EN/IEC 61643-11 standards
  • Recommended for main distribution boards
  • Class I+II (T1+T2) : SPDs tested and specified according to both T1 and T2 test classes

ETIM for 412283 Earthing, lightning and surge protection (EC000941)

Feature nameSystem configuration TN-C-S (EF009933)
Feature valueYes
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP20
Feature nameNominal voltage AC (EF004220)
Feature value400 V
Feature nameSystem configuration TN-S (EF009930)
Feature valueNo
Feature nameConstruction size (EF002566)
Feature value8 modular spacing
Feature nameSystem configuration other (EF009932)
Feature valueNo
Feature nameMounting method (EF000003)
Feature valueDIN rail (top hat rail) 35 mm
Feature nameSystem configuration TT (EF009931)
Feature valueYes
Feature nameSignalling at the device (EF004241)
Feature valueOptic
Feature nameNumber of conductors (without earthing) (EF001148)
Feature value4
Feature nameVoltage protection level (EF003525)
Feature value2.5 kV
Feature nameSystem configuration IT (EF009927)
Feature valueNo
Feature nameSystem configuration TN-C (EF009929)
Feature valueYes
Feature nameSystem configuration TN (EF009928)
Feature valueYes
Feature nameMax. continuous voltage AC (EF004198)
Feature value350 V
Feature nameVoltage protection level N-PE (EF008796)
Feature value1.5 kV
Feature nameIntegrated backup fuse (EF008797)
Feature valueNo
Feature nameVoltage protection level L-N (EF004236)
Feature value1.5 kV
Feature nameNominal discharge surge current (8/20) (EF004214)
Feature value25 kA
Feature nameCategory type 2 (EF004230)
Feature valueNo
Feature nameWith remote signalling contact (EF000422)
Feature valueYes
Feature nameMax. conductor cross section solid (solid, stranded) (EF008827)
Feature value35 mm²
Feature nameMax. conductor cross section flexible (fine-strand) (EF008828)
Feature value25 mm²

DATASHEET - PDF

Title
Size
Type

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.