ANUNCIAR
412242 LEGRAND LIMIT OVERT T2 40KA 3P + SD View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

412242 LEGRAND LIMIT OVERT T2 40KA 3P + SD

412242

LEGRAND

5

LIMIT OVERT T2 40KA 3P + SD

SPD - T2 - Imax 40 kA/pole - 3P

Low voltage surge arrester type T2 Imax 40kA/pole - 3P

More details


Earthing, lightning and surge protection > Surge protection device for power supply systems

MOTOR CIRCUIT BREAKERS

Brand new product in its original packaging covered by the warranties and certifications provided by LEGRAND

Total: $1,139.18
Unit price: $227.84
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



  • Pack (number of units)1
  • Volume (dm3)0.521
  • Weight (g)329.00
Product characteristics
T2 SPDs
  • SPDs with plug-in modules and status indicators:
    • Green: SPD operational
    • Orange: plug-in modules to be replaced
T2 - Imax 40 kA/pole
  • SPDs recommended for power installations
  • Up: 1.7 kV - In: 20 kA/pole - Uc: 320 V~
  • Earthing systems : TT, TNC, TNS
  • Recommended MCB: DX³ 25 A - C curve
  • Number of poles : 3P
  • Remote status monitoring (FS contact) : Yes
  • Number of modules : 3
General characteristics
Class II (T2) low voltage SPDs
  • Protection against transient overvoltagess for 230/400 V~ power networks (50/60 Hz). SPDs compliant with EN/IEC 61643-11 standards
  • Recommended for distribution boards

ETIM for 412242 Earthing, lightning and surge protection (EC000941)
Feature Name Feature Value
System configuration TN-C-S (EF009933) Yes
Degree of protection (IP) (EF005474) IP20
Nominal voltage AC (EF004220) 230 V
System configuration TN-S (EF009930) No
Construction size (EF002566) 3 modular spacing
System configuration other (EF009932) No
Mounting method (EF000003) DIN rail (top hat rail) 35 mm
System configuration TT (EF009931) No
Signalling at the device (EF004241) Optic
Number of conductors (without earthing) (EF001148) 3
Voltage protection level (EF003525) 1.7 kV
System configuration IT (EF009927) No
System configuration TN-C (EF009929) Yes
System configuration TN (EF009928) Yes
Max. continuous voltage AC (EF004198) 320 V
Integrated backup fuse (EF008797) No
Nominal discharge surge current (8/20) (EF004214) 20 kA
Category type 2 (EF004230) Yes
With remote signalling contact (EF000422) Yes
Max. conductor cross section solid (solid, stranded) (EF008827) 35 mm²
Max. conductor cross section flexible (fine-strand) (EF008828) 25 mm²

Datasheet - PDF

Title: Size: Type:
412242 EN_412220.pdf 610 Kbytes     412242 EN_412220.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.