ANUNCIAR
408033 LEGRAND MAGNET DX3 6/10 KA D 2P 25A View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

408033 LEGRAND MAGNET DX3 6/10 KA D 2P 25A

408033

LEGRAND

MAGNET DX3 6/10 KA D 2P 25A

MCB - DX³ 6000 - 10 kA - 2P - 230/400 V~ - 25 A - D curve

DX³ 6000/10kA Circuit Breaker - 2P - 230/400V~ - 25A - D curve

More details


Circuit breakers and fuses > Miniature circuit breaker (MCB)

TERTIARY CIRCUIT BREAKERS

Brand new product in its original packaging covered by the warranties and certifications provided by LEGRAND

Total: $67.40
Unit price: $67.40
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



  • Pack (number of units)1
  • Volume (dm3)0.357
  • Weight (g)313.00
Product characteristics
2-pole 230/400 V~
  • D curve
  • Nominal rating In : 25 A
  • Number of modules : 2
General characteristics
MCBs DX³ 6000 - 10 kA - thermal magnetic MCBs from 0.5 A to 63 A - D curve
  • Conform to IEC 60898-1
  • Compatible with both prong-type and fork type supply busbars
  • Breaking capacity:
  • 6000 - IEC 60898-1 - 400 V~
  • 10 kA - IEC 60947-2 - 400 V~
  • Can be equipped with DX³ signalling and remote tripping auxiliaries, motorised controls and add-on modules

ETIM for 408033 Circuit breakers and fuses (EC000042)
Feature Name Feature Value
Explosion-proof (EF004663) No
Connectable conductor cross section solid-core (EF007337) 1.5 mm²
Ambient temperature during operating (EF007515) -25 °C
Degree of protection (IP) (EF005474) IP20
Concurrently switching neutral conductor (EF005997) No
Voltage type (EF000187) AC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V (EF009555) 6 kA
Additional equipment possible (EF008148) Yes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V (EF009558) 10 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V (EF009557) 25 kA
Rated impulse withstand voltage Uimp (EF011980) 4 kV
Number of protected poles (EF005548) 2
Frequency (EF000416) 50 Hz
Built-in depth (EF000218) 44 mm
Number of poles (total) (EF008618) 2
Pollution degree (EF002570) 2
Width in number of modular spacings (EF002950) 2
Rated insulation voltage Ui (EF001366) 500 V
Connectable conductor cross section multi-wired (EF007343) 1.5 mm²
Rated current (EF000227) 25 A
Flush-mounted installation (EF007517) Yes
Release characteristic (EF000889) D
Rated voltage (EF000228) 400 V

Datasheet - PDF

Title: Size: Type:
408033 EN_408966.pdf 1 Mbytes     408033 EN_408966.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.