MORE INFO
The Keor DK Rack 5-10kVA Parallel Connection Kit is designed to facilitate the integration of uninterruptible power supplies (UPS) in industrial and commercial applications that require high availability and flexibility in power management. This kit allows you to connect several Keor DK Rack UPS units from 5 to 10kVA in parallel, providing redundancy or power expansion according to the needs of the installation.- Allows the parallel connection of Keor DK Rack UPS from 5 to 10kVA, optimizing the continuity of the power supply in critical environments.- Ideal for applications where redundancy is essential, such as data centers, industrial infrastructures, telecommunications systems and IT environments.- Facilitates configuration in both redundancy mode (N+1) and power increase mode, adapting to the specific requirements of each project.- The kit includes an additional card that manages communication and synchronization between connected UPSs, ensuring safe and coordinated operation.- Exclusively compatible with Keor DK Rack models from 5 to 10kVA, ensuring seamless and hassle-free integration.- Does not require USB, RS232 or SNMP interface, simplifying installation and reducing system complexity.- Works with direct current (DC) voltage, adapting to the technical specifications of Keor DK UPS.- It does not have integrated network management, making it a robust solution focused on the main function of parallelization.- It is not modular, which guarantees a solid and stable structure in the connection between equipment.- Does not include switching contacts without potential or automatic disconnection function, focusing its usefulness on the parallel connection.- Does not incorporate C13 or C19 type output sockets, as its function is exclusively the UPS interconnection.- The kit does not have a specific IP protection degree, as it is intended for use in controlled and protected environments.- Operating temperature range from 0 to 40°C, suitable for most technical rooms and industrial environments.- Storage temperature from -10 to 50°C, allowing flexibility in transport and storage prior to installation.- Sound level of 0dB, which ensures that it does not add additional noise to the environment where it is installed.- It does not require its own electrical outlet nor does it contain batteries or accumulators, which simplifies maintenance and management of the system.- Its design is oriented towards maximum reliability and ease of integration, allowing engineers and technicians to implement redundant or higher capacity power solutions without additional complications. Competitive advantages:- Specific solution for the Keor DK Rack range, guaranteeing total compatibility and optimized operation.- Allows to scale the power or redundancy of the UPS system in a simple and secure way, adapting to the growth of the infrastructure.- Quick installation without the need for complex configurations, ideal for projects with tight deadlines or immediate upgrade needs.- Eliminates the need for additional communication interfaces, reducing costs and potential points of failure.- It brings flexibility to the electrical architecture, allowing technical managers to design customized systems according to load and safety requirements.- Its quiet operation and without additional heat generation contributes to maintaining optimal conditions in technical rooms and racks. The parallel connection kit for Keor DK Rack 10-20kVA is the ideal solution for those looking to maximize the security and continuity of the power supply in critical installations, with the guarantee of compatibility and quality of the Keor DK range.
| USB interface | No |
|---|
| With RD 232 communication interface | No |
|---|
| SNMP | No |
|---|
| Network management capability | No |
|---|
| Modulate | No |
|---|
| Potential-free switching contact | No |
|---|
| Automatic switch-off function | No |
|---|
| Input socket | Other |
|---|
| Number of C13 outlet outlets | 0 |
|---|
| Number of C19 outlet sockets | 0 |
|---|
| Protection Class (IP) | Not applicable |
|---|
| Operating Temperature (Min-Max) | 0-40 °C |
|---|
| Storage Temperature (Min-Max) | -10-50 °C |
|---|
| Sound Level | 0 dB |
|---|
| Display of markings on the connection terminals | No |
|---|
| Load Type | Not applicable |
|---|
| With electrical outlet | No |
|---|
| Contains battery and/or accumulator | No |
|---|