MORE INFO
The Keor DK 1-10kVA dry contact card is an essential accessory designed for uninterruptible power supply systems of the Keor DK range, optimizing integration and control in industrial and commercial environments where remote monitoring and signaling of critical states are a priority. This module allows the transmission of UPS status signals to external systems through potential-free switching contacts, facilitating the management and supervision of the electrical infrastructure without the need for additional digital communication interfaces.- It allows the signaling of different UPS functions through potential-free contacts, both normally open and normally closed, ensuring flexible integration with automation, alarms or centralized control systems.- Compatible with Keor DK models from 1 to 10kVA, ensuring wide coverage for single-phase installations of different capacities within the same product family.- Works exclusively with direct voltage (DC), simplifying integration into control systems and reducing installation complexity.- No USB interface required, RS-232 or SNMP, which minimizes exposure to network vulnerabilities and simplifies configuration in environments where security and reliability are critical.- The input connection is fixed, which provides a robust and secure installation, avoiding accidental disconnections and guaranteeing service continuity.- It does not have C13 or C19 type output sockets, since its main function is signaling and not power distribution, making it a specific and optimized solution for monitoring.- The sound level is 0dB, ensuring completely silent operation, ideal for noise-sensitive environments such as server rooms, laboratories or control centers.- Operating temperature range from 0 to 40°C, suitable for most industrial and commercial environments, and storage range from -10 to 50°C, facilitating logistics and safe storage of the product.- It does not require batteries or accumulators, eliminating the need for additional maintenance and reducing long-term operating costs.- Does not include automatic shutdown function, ensuring that the signaling remains active while the UPS is in operation, providing real-time information on the status of the system.- It is not modular, which simplifies installation and reduces the risk of incompatibilities or configuration errors.- It does not have a specific IP protection degree, as it is designed for integration inside Keor DK equipment, where there is already adequate protection against external agents. Competitive advantages and outstanding applications:- Ideal solution for monitoring critical UPS statuses, such as network failure, battery operation, active bypass or general alarm, allowing direct integration with building management systems (BMS), programmable automatons (PLC) or alarm panels.- The use of potential-free dry contacts avoids electrical interference and allows safe connection to control devices of different voltages and technologies, increasing the versatility of the installation.- Its specific design for the Keor DK range guarantees total compatibility and maximum operational reliability, avoiding integration problems and ensuring Legrand's specialized technical support.- As it does not depend on network interfaces or communication protocols, the dry contact card is especially suitable for environments where information security and system robustness are priorities.- Facilitates preventive management and rapid response to electrical incidents, as it allows the activation of visual or audible alarms, the sending of signals to remote monitoring systems or the execution of automatic actions in the event of UPS failure.- Its simple and direct installation reduces commissioning times and the costs associated with the integration of monitoring systems in critical infrastructures. In summary, the Keor DK 1-10kVA dry contact card is a robust, reliable and highly compatible solution for status signaling in UPS systems, aimed at professionals who require efficient and secure integration in industrial, commercial or mission-critical environments. Its optimized design for the Keor DK range, together with the simplicity of installation and the absence of maintenance, make it the preferred choice for monitoring and control of uninterruptible power in modern installations.
| USB interface | No |
|---|
| With RD 232 communication interface | No |
|---|
| SNMP | No |
|---|
| Type of voltage | CC |
|---|
| Network management capability | No |
|---|
| Modulate | No |
|---|
| Potential-free switching contact | Yes |
|---|
| Automatic switch-off function | No |
|---|
| Input socket | Fixed connection |
|---|
| Number of C13 outlet outlets | 0 |
|---|
| Number of C19 outlet sockets | 0 |
|---|
| Protection Class (IP) | Not applicable |
|---|
| Operating Temperature (Min-Max) | 0-40 °C |
|---|
| Storage Temperature (Min-Max) | -10-50 °C |
|---|
| Sound Level | 0 dB |
|---|
| Display of markings on the connection terminals | No |
|---|
| Load Type | Not applicable |
|---|
| With electrical outlet | No |
|---|
| Contains battery and/or accumulator | No |
|---|